Photochemical Reactor
-
Stand, Photochemical Reactor
Ace Glass7837-75 universal, small reactor stand accomodates 250-1000ml vessels through the use of 7837 series PTFE inserts. Manufactured of powder coated aluminum, our stand may be used with our 7840,7841,7844,7861, 7863,7864 and 7865 jacketed and unjacketed reactors. Stand is 27cm high. 7837 code -50 and…
-
Photochem Reactor, Ace-Thred, Plain
Ace GlassGlass, unjacketed reaction vessel design for use with our 7874 quartz and 7875 glass immersion wells. Instead of a standard taper joint, this reactor utilizes a height-adjustable, non-freezing #50 Ace-Thred. Also featured, a 14/20 angled joint for a sparger tube, a 24/40 vertical joint for a…
-
Photochem Reactor, Ace-Thred, Jacketed
Ace GlassGlass, jacketed reaction vessel design for use with our 7874 quartz and 7875 glass immersion wells. Instead of a standard taper joint, this reactor utilizes a height-adjustable, non-freezing #50 Ace-Thred. Also featured, a 14/20 angled joint for a sparger tube, a 24/40 vertical joint for a condenser…
-
Photochem Reactor, Plain & Jacketed
Ace Glass…joint for sparger tube, one 24/40 vertical joint for condenser and one #7 Ace-Thred side arm for thermometer. Center joint is 60/40. Bottom of reactor is flat to allow use of stirrer magnet. Volumes indicated are total volumes. Volume in reactive area of lamp is approx. 40-50% of total volume.…
-
Vessel only, enables cooling of reactant material during photolysis plus the added feature of a 2mm bore, 1:5 PTFE stopcock at bottom for draining contents of vessel. Made of borosilicate glass to accommodate the immersion well. With one 14/20 angled joint for sparger tube, one 24/40 vertical joint…
-
Glass, jacketed reaction vessel design for use with our 7874 quartz and 7875 glass immersion wells. Instead of a standard taper joint, this reactor utilizes a height-adjustable, non-freezing #50 Ace-Thred. Also featured, a 14/20 angled joint for a sparger tube, a 24/40 vertical joint for a condenser…
-
Turntable Reactor, Photochemical
Ace GlassAce photochemical reactor turntable for the determination of relative and absolute quantum yields. Variable height disc holds 13mm OD sample tubes, 33 in outer circle, 18 inner. Unit will hold up to four 7891 series square filters. Complete unit includes motor and control, CE rated. Not included:…
-
Platform Reactor, Photochemical
Ace GlassUsed for radiating metals in water to obtain metal-free water and to remove unbound chlorine from drinking water. Reactor consists of a top platform with eight 33 mm I.D. sample tube holes encircling a 40 mm lamp well hole, middle platform adjustable height , 0-20.5 cm, and a lower platform holding…
-
Kriel Reactor, Photochemical
Ace GlassReactor is most useful in prep-scale photolysis and features tapered sides which assures full submersion using our 7825-34 or 7825-36 lamps within the supplied quartz immersion well. A 20% savings in reaction time over round bottom flasks. Additionally
-
Microscale photochemical reactor with internally threaded connections both top and bottom of head. Top is #15 Ace-Thred that accepts 12.5-14mm O.D. tubes such as 9720-23 Finger Condenser; bottom is #25 Ace-Thred that accepts a 24mm O.D. quartz or glass (borosilicate) tube for photolysis experiments.…
-
Knitted reactor coil L x I.D. 20 m x 0.25 mm, volume 1.0 mL
MilliporeSigmaKnitted reactor coil is used with PHRED photochemical reactor, to determine the duration of exposure to ultraviolet radiation (UV) for the detection of analytes.
-
Quartz immersion well, triple-walled, 60/40 inner joint for use in our 7841 and 7844 series photochemical reactor bodies. Designed for low temperature reactions cooled up to -78 degrees C. The outer two walls are permanently sealed and evacuated. The inner removable tube set consists of one each…
-
Immersion Well, Photochemical, Plain
Ace GlassQuartz immersion well, triple-walled, unjointed (plain) for use in our 6962,7863,7864,7865 & 7891 series reactor bodies. Designed for low temperature reactions cooled up to -78 degrees C. The outer two walls are permanently sealed and evacuated. The inner removable tube set consists of one each…
-
Complete with all parts needed for immediate operation. Borosilicate glass reactor has a 60/40 center joint, one 14/20 angled joint for sparger tube, 24/40 vertical joint for condenser, and one #7 Ace-Thred for thermometer. Volumes indicated are total volumes. Volume in reactive area of lamp is…
-
Similar to our larger units but is designed for carrying out reactions on a small scale, volumes of 5-15mL. Reactor body is fabricated of borosilicate glass with #25 Ace-Thred at top, 14/10 outer side joint externally threaded to allow an O-RING-CAP-SEAL connection with mating inner joint, and…
-
Jacketed quartz immersion well for use with our 7825 series lamps within our 6962,7863,7864,7865 & 7891 series reactors. Codes -23 & -35 feature a small diameter quartz inner feed tube to ensure the flow of coolant from the bottom of the well up to the outlet. Codes -26 & -38 feature a PTFE inner…
-
Jacketed glass immersion well for use with our 7825 series lamps within our 6962,7863,7864,7865 & 7891 series reactors. Codes -30 & -40 feature a small diameter glass inner feed tube to ensure the flow of coolant from the bottom of the well up to the outlet. Codes -35 & -45 feature a PTFE inner feed…
-
EvoluChem™ PhotoRedOx Box
HepatoChem…reaction time and allows to be run in continuous mode for scale-up. To solve this challenge, we designed a flow reactor that can be used in the PhotoRedOx Box. This flow reactor is using PFA tubing and has volume of 2mL. Comparing reactions in flow and in batch we observed significant decrease…