Incubator Filters

Compare Tool

Select up to 3 products

Incubator Filters
1 - 32 of 74
Sort
View
Show

GE Pink

  • Whatman HEPA-VENT Vent Filters

    GE Healthcare

    …venting filters from GE Healthcare’s Life Sciences business are available for a variety of applications. In addition to Whatman HEPA-VENT filters, Whatman HEPA-CAP capsule venting filter is available to support greater filtration volumes. Whatman HEPA-VENT industrial air filter HEPA air filter

  • Whatman PolyVENT Integral Vent Filters

    GE Healthcare

    …filling. Whatman venting filters from GE Healthcare’s Life Sciences business include HEPA filters and SteriVENT options. Whatman PolyVENT venting filter Draining or filling of incubators, fermentation tanks, and other vessels requires a venting filter capable of preventing…

  • AcroVent® Device

    Pall Life Sciences

    Economical, Disposable 50mm Device for Routine Venting. Decreases contamination risks. Ideal for gas lines for CO2 incubators

  • Membrane Marking Pen

    GE Healthcare

    …transfer procedures. This indispensable tool ensures easy identification and orientation of gel transfers, colony and plaque lifts, and Western blots, even when the membrane is damp. It is compatible with hybridization and incubation buffers. An excellent marker for keeping records of transfers.

  • Whatman Polycarbonate Cell Culture Membrane Filters

    GE Healthcare

    incubation time and the need to sterilize Cell culture filter suitable for biological applicationsThin and uniform cylindrical pores for rapid cell migrationOffered without the standard PVP wetting agent for increased cellular adhesion in applications such as neutrophil chemotaxisReduces incubation

  • Replacement HEPA Filters and Cleaning Kits

    Thermo Scientific

    Help ensure measurable Class 100 air quality performance with Thermo Scientific™ Replacement HEPA Filters and Cleaning Kits.

  • Mixed Cellulose Ester Membranes

    GE Healthcare

    …colony counting after incubation as the standard method of quantitation. Whatman gridded filters have clearly defined grid lines spaced at 3.1 mm or 5 mm intervals. The special ink used is nontoxic and completely free from bacterial growth inhibitors. Sterile filters For those…

  • Mixed Cellulose Ester Membranes, 3µm

    GE Healthcare

    …cellulose nitrate. These membranes are characterized by a smoother and more uniform surface than pure nitrocellulose filters. Also, the color contrast provided by the filter surface facilitates particle detection and minimizes eye fatigue. The ME range has a lower cellulose acetate content compared…

  • Model SCO5A & SCO10A Air Jacketed CO2 Incubators

    Shel Lab

    …cell culture applications. Model SCO10A is a stacked version of our SCO5A incubator. It provides the benefits of contamination control and uncompromising temperature uniformity for even the most demanding incubations. Standard Design Features: Infrared (IR) CO2_Sensor…

  • Whatman Sterile Mixed Cellulose Ester Membranes, 0.45 µm

    GE Healthcare

    …cellulose nitrate. These membranes are characterized by a smoother and more uniform surface than pure nitrocellulose filters. Also, the color contrast provided by the filter surface facilitates particle detection and minimizes eye fatigue. The ME range has a lower cellulose acetate content compared…

  • Mixed Cellulose Ester Membranes, 0.8µm

    GE Healthcare

    …cellulose nitrate. These membranes are characterized by a smoother and more uniform surface than pure nitrocellulose filters. Also, the color contrast provided by the filter surface facilitates particle detection and minimizes eye fatigue. The ME range has a lower cellulose acetate content compared…

  • Mixed Cellulose Ester Membranes, 0.45µm

    GE Healthcare

    …cellulose nitrate. These membranes are characterized by a smoother and more uniform surface than pure nitrocellulose filters. Also, the color contrast provided by the filter surface facilitates particle detection and minimizes eye fatigue. The ME range has a lower cellulose acetate content compared…

  • Whatman Non-Sterile Mixed Cellulose Ester Membranes 0.45 µm

    GE Healthcare

    …cellulose nitrate. These membranes are characterized by a smoother and more uniform surface than pure nitrocellulose filters. Also, the color contrast provided by the filter surface facilitates particle detection and minimizes eye fatigue. The ME range has a lower cellulose acetate content compared…

  • Whatman Nuclepore Polycarbonate Membranes - Black

    GE Healthcare

    …GE’s Nuclepore membrane filters are compatible with the direct epifluorescent microscopy filter technique (DEFT), which allows microorganisms to be counted directly on a filter. DEFT can be conducted in under half an hour, sidestepping the standard > 24 hour process of incubating a microbial sample.…

  • MaxQ 8000 Incubated Stackable Shakers

    Thermo Scientific

    …on the floor for space savings in the lab. MaxQ 8000 stackable shakers have the durability to run at top speed stacked three-high, contain a HEPA filter that ensures the air inside the chamber remains clean and reduces cross contamination, feature a slide out platform that provides convenient 100%…

  • Water Jacket CO2 Incubators

    Thermo Scientific

    … In-chamber HEPA filter snap-fits, making it easy to remove without tools Class 100 HEPA Filtered Air Protection Class 100 HEPA airflow is the preferred method of protection of water jacket incubators. Inchamber HEPA air filtration system continuously filters the entire chamber…

  • Nunclon Treated Tissue Culture Flasks, Filter Cap

    Thermo Scientific Nunc

    …is necessary Sterile Cap contains 0.22 mm hydrophobic filter, which prevents wetting and bacteria from growing through membrane while allowing quick, stable buffering in aCO2 incubator. Filter membrane has a three-dimensional matrix of polyethylene fibers. Plug-seal…

  • Hybridization Incubators

    Techne (Bibby Scientific US)

    Temperature range 30° to 100°C At least five 20 x 20 cm filters can be probed in a single hybridization chamber in DNA experiments Holds up to a maximum of six hybridization tubes (maximum of five membranes per tube); includes three Hybridization Tubes (Thomas number 7187D22) …

  • Qualitative Filter Papers, Ahlstrom 601

    Ahlstrom

    … ASTM E1963-09.A2 Standard Guide for Conducting Terrestrial Plant Toxicity Tests: Root Elongation Seeds are incubated under controlled conditions in petri dishes with filter paper, such as Grade 601, prior to measuring the root length to determine if a potentially toxic substance has affected…

  • AcroPrep™ Advance 96-Well Filter Plates for Multiplexing

    Pall Life Sciences

    …faster, more uniform filtration rates across the plate with reduced hold-up volume New outlet tip geometry minimizes sample leakage and loss during incubation steps so that acquisition times are not affected Intrinsic plate and membrane properties minimize target loss from non-specific binding

  • Model SCO5W Water Jacketed CO2 Incubators

    Shel Lab

    Model SCO5W water jacketed CO2 incubator and is an ideal unit for cell culture applications. It provides a precisely controlled, accurate, pure environment throughout the culturing process. Shel Lab CO2 incubators are designed to provide the uniform temperatures and highly…

  • Model SCO2W Benchtop Water Jacketed CO2 Incubators

    Shel Lab

    Model SCO2W water jacketed CO2 incubator and is an ideal benchtop unit for cell culture applications. It provides a precisely controlled, accurate, pure environment throughout the culturing process. Shel Lab CO2 incubators are designed to provide the uniform temperatures and…

  • MaxQ™ HP Incubated and Refrigerated Console Shakers

    Thermo Scientific

    … Unique HEPA filtration system HEPA filter rated a minimum 95% efficient at 0.3μm for entrapment of extraneous airborne particulats Laminar airflow across the chamber aids temperature uniformity Low-end temperature achieved by filtered, front-to-back refrigeration system airflow …

  • AquaScreen® Fast Extract

    Minerva Biolabs

    … Membrane filters Incubation dishes Incubation, collection and sample storage tubes Lysis, wash and elution buffers Required Lab Equipment & Consumables Vacuum pump Microcentrifuge Filtration system, 47 mm frit Pipets and filter tips Incubator (37 °C…

  • M-EMB Broth

    HiMedia

    filters through which the test water sample has been passed are initially enriched for 2 hours by incubating the filter on M-Enrichment Broth (M1109). These enriched cultures (filters) are then transferred onto sterile absorbent cotton pads saturated with 2 ml of M-EMB Broth (M1105). Incubation is…

  • Bioassay Dish Low Profile Sterile PS

    Thermo Scientific Nunc

    Useful for screening large numbers of colonies in cloning experiments as well as culturing of bacteria and fungi Suitable in agar diffusion assay Lined with wet filter paper, it is also useful as an incubation chamber for in situ hybridization Large growth area

  • MEL/MF Total Coliform Laboratory

    Hach

    …MEL offers all the equipment and accessories to perform microbiological analysis. Contains: Portable Incubator and rack, Thermometer, Whirlpak bags with thiosulfate (200), Filter funnel/pad assemblies (200), alcohol burner (order alcohol separately), vacuum filtration apparatus, colony…

  • EasyFlasks™ PDL & Collagen 1 Coated

    Thermo Scientific Nunc

    …non-pyrogenic Filter Caps: Vent/close and filter caps are available Filter caps are fitted with a hydrophobic filter to ensure consistent gas exchange "Y"-mark allows visual verification of vent position, even when stacked in incubators Ordering…

  • Microfil V Filtration Device

    MilliporeSigma

    … The Microfil V device's filter support has a curved edge, so you can easily remove the mem/pane after filtration while vacuum is still applied. (This removes excess water that could cause growth around the rim of the filter during incubation). Consistent Recoveries Microfil…

  • Flow-Mesh

    Diversified Biotech

    …highly permeable support for incubating membranes and gels. Flow-Mesh protects filter or gel from tearing, bending and folding while being inserted into a confined space such as a hybridization bag or a roller bottle. Mesh also provides support during incubation with nucleic acid probes,…

  • M-EC Test Agar

    HiMedia

    …are the pH indicators. Filter the sample through a membrane filter. Place the membrane on M-EC Test Agar and incubate at 35 ± 0.5°C for 2 hours to rejuvenate injured or stressed bacteria and then incubate at 44.5 ± 0.2°C for 22 hours. Transfer filter to a filter pad saturated with urea substrate…

  • M-Enterococcus Agar Base, Modified

    HiMedia

    filter the water is placed on to M-Enterococcus Agar, Modified plate and incubated at 41°C for 48 hours and after incubation transferred to the Esculin Iron Agar plate and further incubated at 41°C for 20 minutes. After incubation, count and record the colonies on those membrane filters

Compare Tool