Heating Chamber
-
…are suited to drying and heating. The attributes of the Solid.Line are geared towards the application in question and therefore used in research and quality assurance. Temperature range: ambient temperature +7°C to 250°C APT.line™ preheating chamber technology Natural…
-
…suited to drying and heating. The attributes of the Solid.Line are geared towards the application in question and therefore used in research and quality assurance. Temperature range: ambient temperature +10°C to 250°C APT.line™ preheating chamber technology Forced…
-
Heating ovens with mechanical control With the E series heating oven, you obtain a reliable and powerful unit in a solid configuration at a very attractive price. Temperature range: 60°C to 230°C Adjustable exhaust air flap Hydro-mechanical thermostat Class 1…
-
Temperature range: room temperature plus 5°C to 300°C APT.line™ preheating chamber technology Forced convection Adjustable exhaust air flap Controller with timer functions 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with…
-
Temperature range: room temperature plus 5°C to 300°C APT.line™ preheating chamber technology Gravity convection Adjustable exhaust air flap Controller with timer functions 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with…
-
Temperature range: ambient temperature plus 5°C to 300°C High temperature accuracy thanks to APT.line™ technology Gravity convection Controller with LCD display Electromechanical control of the exhaust air flap 2 chrome-plated racks Units up to 115L are stackable …
-
Temperature range: ambient temperature plus 10°C to 300°C High temperature accuracy thanks to APT.line™ technology Forced convection Controller with LCD display Electromechanical control of the exhaust air flap 2 chrome-plated racks Units up to 115L are stackable …
-
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating – even for chambers under full loads. Benefits High temperature accuracy thanks to APT.line™ technology User-friendly controller…
-
…chamber with forced convection The forced convection of an FP series chamber provides reliably short drying times and particularly fast heating - even for chambers under full loads. Temperature range: room temperature plus 5°C to 300°C APT.line™ preheating chamber…
-
…deposits will not impair drying results. The preheating chamber allows all connecting tubes to the inner chamber to be subjected to the heating process, reducing the risk of condensation in the inner chamber. High-quality insulation reduces heat dissipation, which contributes to an active reduction…
-
…via the 50 mm-exhaust duct. The patented preheating chamber technology provides for temperature fluctuation of ±0.4°C. The dual chamber design, with heating elements placed below and on both sides of the slotted inner chamber walls, and powerful turbine provides a horizontal airflow…
-
Temperature range: ambient temperature plus 10°C to 300°C Up to 30% lower energy consumption compared to conventional units on the market High temperature accuracy thanks to APT.line™ technology Adjustable fan speed Controller with LCD display and enhanced time functions …
-
Vacuum Chamber Digital Heat Pads
Best Value VacsChamber NOT Included, Sold Separately. Heat Pad must fit correct size of chamber! 1182R19 (9") fits our 2, 3 and aluminum pots and 3QT & 1GL Flat Chamber 1182R20 (10") fits 5 Gallon aluminum pots and 1.6 Flat Chamber This Fahrenheit Heat Pad will adhere to the bottom…
-
…such as zirconium oxide dental bridges. Tmax 1600°C, 1750°C, or 1800°C High-quality molybdenum disilicide heating elements Furnace chamber lined with first-class, durable fiber material Housing made of sheets of textured stainless steel Dual shell housing with…
-
…1500°C, or 1600°C. The durability of the SiC rods in periodic use, in combination with their high heating speed, make these furnaces to all-rounders in the laboratory. Heating times of 40 minutes to 1400°C can be achieved, depending on the furnace model and the conditions of use.…
-
…Chambers allow for drying of bulk samples, or drying of serum bottles, vials or microplates. The 10" diameter shelves are wireless and removable so that they may be placed in a freezer for pre-freezing. Each shelf is height adjustable to accommodate a broad variety of sample sizes. Chamber…
-
SYNTHWARE Abderhalden Drying Chamber
Kemtech AmericaDrying samples for elemental analysis. Sample is placed in a vial which is placed into drying chamber. Under vacuum and gentle heat created by refluxing in outer jacket of low boiling point solvents.
-
Precision™ Compact Heating and Drying Ovens
Thermo Scientific…low turbulence: air is moved vertically through chamber to heat samples Preset high-temperature safety bimetallic thermostat ensures overtemperature protection Mechanical-Convection Models (1226S06 & 1226S07) Uniform heating, precise temperature control and fast drying …
-
Aluminum Small Chamber
BiospecThick-walled aluminum chamber with Teflon rotor. Working volume is 15 ml. The chamber can be precooled and the superior heat capacity and large mass of the 1/2 inch thick aluminum walls will keep the sample cold. The SASC-15 can also be combined with the BeadBeater ice water jacket (the later comes…
-
Professional Chamber Furnaces
Nabertherm… Tmax 1200°C, 1300°C, or 1400°C Five-sided heating for very good temperature uniformity Heating elements on support tubes ensure free heat radiation and a long service life Protection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor…
-
UV Clave Ultraviolet Chamber
Benchmark Scientific…top and bottom of the chamber. When combined with our proprietary shelf that allows for 90% of UV-C light transmission and highly reflective chamber walls, the result is true 360° exposure with no blind spots. Exposure time is adjustable. An optional heating cycle can be added to…
-
Temperature Test Chamber
Corepoint Scientific…air distribution Top mounted, variable speed compressor Hydrocarbon natural refrigerant Multi-element, independent proportional electric heating Temp sensor Type: NTC Condensate evaporation Shielded, switched interior LED lighting Heavy duty door handle Magnetic door gasket…
-
Clear Stoppering Chamber
Labconco…2 to 5 mL Clear Stoppering Chamber provides an economical means of stoppering serum bottles under original vacuum. Unit consists of a clear acrylic cylinder, stainless steel top plate, two 10-in. diameter shelves and a low voltage transformer with variable heat control to 40°C (104°F),…
-
…of the heating elements from aggressive atmospheres. Another aspect is the smooth, nearly particle free muffle (furnace door made of fiber insulation), an important quality feature for some ashing processes. Tmax 1100 °C Muffle heated from four sides Furnace chamber with embedded…
-
Memmert Constant Climate Chamber (HPPeco) - this programmable model is the 115 volt, Peltier-technology seamlessly heats and cools, with TwinDISPLAY digital controller. HPPeco humidity range is 10 to 85% rh without light (upto 90% with light). Each individual appliance is tested according to the…
-
Lab Companion Plant Growth Chamber
Jeio Tech…and low thermal load. (for GC-1000TLH/1000TL) Unique construction for minimization of heat increase from surrounding lamps. Tempered glass door blocks heated air from lamps. Designed to exhaust heated air through upper vent holes. (for GC-1000TLH) Stable and long-lasting lighting…
-
…annealing systems. Tmax 1280°C Deep furnace chamber with three-sides heating: from both side walls and bottom Heating elements on support tubes ensure free heat radiation and a long service life Bottom heating protected by heat-resistant SiC plate Low energy consumption…
-
… The fastest high heat decontamination cycle on the market without having to remove critical components Heated door to ensure superior temperature uniformity and also reduce the potential for condensation to form on the inner glass door Durable stainless steel chamber with coved corners for…
-
…which incorporates the ESI cyclonic spray chamber. In cooling mode the PC 3X cools the outer walls of the cyclonic spray chamber, reducing the water or solvent vapor loading on the plasma, resulting in enhanced stability and performance. In heating mode, sensitivity can be improved for low flow…
-
HCP Series Humidity Chambers
Memmert…short recovery times after opening the door in this attractively priced and practically maintenance-free climate chamber. In combination with heating on all six sides, including heated inner glass door, it also minimises vaporisation in the interior and thus the risk of condensed water dripping onto…
-
Cyanoacrylate Fuming Chambers
Mystaire®…cycle time and relative humidity levels between 50-80%. Using the CA Series is simple; position the non-porous evidence inside the chamber, add cyanoacrylate to the heating element and push the start button to begin fuming. The evidence technician can set fume cycle time and relative humidity…
-
5504-7645 Glovebox Chamber Package, 115 Volt - No Temperature Control; Humidity …
Electro-Tech Systems…university research. Uses can vary from a basic chamber to a full-featured, precision humidity and temperature control environment utilizing accessories including Temperature/Humidity controllers, along with humidification, dehumidification, heating and cooling systems. ClearViewTM Acrylic…