PerkinElmer, Supplies
-
-
All our syringe filters are HPLC certified. Typical Applications: HPLC sample preparation Routine QA/QC analysis Content uniformity Removal of protein precipitates Dissolution testing Biofuel analysis
-
Edwards 45 Vacuum Pump Oil
PerkinElmerThe Edwards 45 1 Liter vacuum pump oil features a non-toxic, non-corrosive formulation and is used in mass spectrometry applications. The presence of hydrocarbon synthetic polymer provides good chemical inertness, temperature stability and low vapor pressure.
-
All our syringe filters are HPLC certified. Housing Material: Polypropylene Effective Filtration Area (cm2): 4.08 Pore Size (µm): 0.45 µm Holdup Volume (µl): <100 Sample Volume (mL): <100 Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating…
-
Ultra Clean Filter Bundle of 3 for GC. Includes (1) Oxygen/Moisture/Hydrocarbon Trap and (2) Hydrocarbon/ Moisture Traps.
-
Quartz Tube with Au/Pt Gauze for Amalgamation System
-
Aluminum Capsules, 4 µL0
PerkinElmerTwo sizes of aluminum capsules are available. The smaller, with an internal volume of 4 mL, can hold sample weights up to 2.5 mg. The larger, with a 30 mL internal volume, accommodates samples up to 20 mg. Sealing of the larger capsule should be carried out in the presence of helium or argon to…
-
Sampler Cone Gasket for NexION 1000/2000/300/350
PerkinElmerPrecision-designed and manufactured, large-ori ce sampler and skimmer cones provide superior long-term stability and resist clogging, allowing analysis under both high and low sample-uptake conditions. Nickel is a very rugged, long-lasting material for the majority of sample types, while platinum…
-
Copper Diffusion Plug
PerkinElmerThe best way to assure consistent, accurate results from your Organic Elemental Analyzer is to use only the highestgrade of reagents. Our scientists select the purest raw materials, condition them,then test them on PerkinElmer analyzers.
-
-
This Pure Flared PVC tubing is green/yellow color-coded and has an interior diameter of 0.44 mm.
-
From instrument installation to instrument calibration, we provide quality set-up, check and calibration standards to ensure instrument performance.
-
Cap for High Pressure 100 mL (100 Bar) Digestion vessels without DPC pressure sensor for Titan MPS 8 Position Microwave Sample Preparation Systems. Includes Vessel Cap made of TFM with pressure sensor for High Pressure 100 mL (100 Bar) Digestion Vessel.
-
Combustion Tube for CHN Analysis, Quartz
PerkinElmerFused quartz has been chosen because of its very high purity and low thermal expansion rate. Because we care about your safety, all combustion tubes are pressure-tested to eliminate any tubes which might contain weak spots. In addition, stringent specifications are used to insure that the…
-
DTA Calibration Reference Material, Aluminum, Transition Point: 660.10C
-
0.8mm ID Sample Loop, PTFE, 2mL, connects to ports, #1 and #4 SC-FAST high-flow (-28 fittings, 1.6mm OD x 0.8mm ID tubing)
-
GC Syringe, 50µL Fixed Needle, Point Style #2
PerkinElmerGC injector syringes each with a fixed needle and various syringe capacities for to match specific chromatographic techniques.
-
Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with less volatile organic solvents, e.g., xylene. The 2.0 mm i.d. Alumina injector is shipped standard with all PerkinElmer ICP-OES instruments. A variety of sizes are available as an…
-
The exceptionally uniform temperature distribution obtained with transverse heating significantly reduces or eliminates condensation of the sample matrix components and "memory" effects and improves the atomization efficiency for refractory elements. For improved characteristic mass with volatile…
-
Liner for High Pressure 100 mL (100 Bar) Digestion Vessel made of TFM for Titan MPS 8 Position Microwave Sample Preparation Systems.
-
Recommended as a source of high purity nitrogen purge gas. Nitrogen is separated from ambient air by a patented pressure swing adsorption process using a carbon molecular sieve (CMS) to differentially absorb oxygen, carbon dioxide, water vapor, etc.
-
Hayman Microspatula
PerkinElmerThis spatula is for fine operations and no-spill carrying of small quantity samples.
-
These convenience kits hold 100 2 mL Clear Screw Top Vials and 100 preassembled Black Caps with PTFE/Silicone Pre-slit Septa together in an environmentally clean, re-sealable clamshell pack. Volume: 2 mL Size: 12 x 32 mm I.D.: 10 mm Finish: Screw Top with Closure Kit Description: Amber glass…
-
20 mL PFA Bottles with Caps
PerkinElmerPFA bottles and vials are ideal for a wide range of demanding fluid handling and storage applications in general laboratory, semiconductor and environmental industries.
-
-
-
A burner chamber endcap with Kalrez o-rings. Fits the PerkinElmer PinAAcle 500 and 900F/H/T AA instruments equipped with a high sensitivity nebulizer with Kalrez o-rings.
-
-
Spectrum 10 STD
PerkinElmerSpectrumTM 10 software is designed for the latest range of PerkinElmer FT-IR spectrometers. This comprehensive package sets the standard in FT-IR software for simplicity and efficiency in data collection, processing and generating results. The softwares interface combines single-click access to…
-
Capillary Assembly for High Sensitivity GemTip Nebulizers
-
The sealed liquid cells have a corrosion-resistant construction making them ideal for highly volatile samples. The sealed liquid cells are ideal for quantitative analysis where you require an accurate reproducible cell thickness. These cells use a lead spacer which is amalgamated to the window…
-
Micro Cell Holder, 10mm Cuvettes for LAMBDA 365
PerkinElmerDesigned for accurate positioning of small volume cuvettes. Accommodates any standard 10 mm cells and Nano Sticks.