Hamilton
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
-
Cemented needles on 8928B58-64 Removable needles on 8928B67 Length: 2” Point style: 2 See 8928C40 for needle for 8928B67.
-
700 Series Microliter Syringes
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. The stainless steel plunger is manufactured to fit the glass barrel with a tolerance less than three thousandths of a millimeter, resulting in unsurpassed syringe life. This series of syringes is ideal for dispensing volumes from…
-
Metal and Kel-F® hub 304 stainless steel needle Standard 2” length Use with Luer Tip and Luer Lock syringes sold without needle or for Luer adapters. Nickel-plated brass or Kel-F (CTFE) hubs fit both male and female Luer connectors.They allow quick change of needle and use…
-
PRP-1 Reversed Phase HPLC Columns
HamiltonPolymeric 100 Å columns for general reversed phase separations. pH stable from 1 to 13 Better sample recovery than silica-based columns (there are no silanol groups) Excellent durability (stable to any concentration of water or organic solvent) Five particle…
-
1700 series, gastight syringes with cemented needles. Length: 1.71 23s-26s gauge AS Point Style
-
Syringes
HamiltonThe 1700 series syringes are the gas tight version of the original 700 series syringes. This series of gas tight syringes is ideal for dispensing volumes from 1 µL up to 500 µL. A variety of different terminations and needle options are available in this series.
-
1000 Series Gastight Syringes
HamiltonTeflon ® PTFE tipped plungers Replaceable barrels, plungers and tips mL sizes For use with liquids or gases. Features a precision-machined Teflon plunger tip which, when wetted, forms an interference fit with the inner diameter of the glass barrel, achieving the seal required for…
-
1000µL Pipette Tips
HamiltonThese tips are used with Hamilton 1000 μL SoftGrip and SofTouch pipettes. They are provided in different packaging types, surface textures, and filter options.
-
Syringe 7001Khwg 1Ul (25S/2.75"/3)
HamiltonVolume 1 µL Termination Knurled Hub (KH) Needle Knurled Hub (KH) Gauge 25s gauge Point Style 3 Needle Length 2.75 inch (69.9 mm) Needle Inner Diameter 0.005 inches (0.13 mm) Needle Outer Diameter 0.019…
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Syringe 1705Dx 50ul
HamiltonVolume 50 µL Syringe Type Gastight Syringe Series 1700 Termination Diluter PTFE Luer Lock (D) Needle No Needle Available Fluid Path Borosilicate glass, PTFE, PCTFE Plunger Style Instrument Plunger Stop (X) …
-
1750LTN 500UL DIGITAL SYRINGE
HamiltonGas Sterilizable No Volume 500 µL Syringe Type Gastight Syringe Series 1700 Termination Luer Tip Cemented Needle (LTN) Needle Cemented Needle Gauge 22 gauge Point Style 2 Needle Length 2 inch…
-
7102KH 2UL PT2 DIGITAL SYRINGE
HamiltonVolume 2 µL Syringe Type Microliter Syringe Series 7000 Termination Knurled Hub (KH) Needle KH Gauge 23 gauge Point Style 2 Needle Length 2.75 inch (69.9 mm) Needle Inner Diameter 0.0081 inches…
-
HPLC Column
HamiltonPRP-X200 columns can quickly resolve alkali metals, alkaline earth metals, and ammonium. One unique feature of this column is that the resolution between any two ions in the alkali metal series can be increased or decreased by changing the concentration of methanol in the mobile phase; allowing…
-
-
-
Syringe 1702Dx 25ul
HamiltonAutoclavable No Fluid Path Borosilicate glass, PTFE, PCTFE Volume 25 µL Syringe Type Gastight Syringe Series 1700 Termination Diluter PTFE Luer Lock (D) Needle No Needle Available Plunger Style Instrument…
-
Length: 2” Point style: 3 For use with Rheodyne, Valco™ VISF-2, Beckman®/Altex and SSI injection valves. Syringes are available with cemented or removable needles and feature Teflon® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. See…
-
HVX Valve
HamiltonThe Hamilton 1-1 HVX valve can be threaded with fittings, adapters, male and female luers, FEP tubing assemblies and adapters. With PTFE/CTFE fluid path, this 94.1 uL valve is made of aluminum housing which ensures high strength and durability. It can be operated manually. This valve operates at a…
-
Syringes
HamiltonThe Hamilton 700 series 10 uL syringe is compatible with small removable needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 115 degree F.
-
Large Hub RN Needle
HamiltonLarge Hub Removable (RN) needles can be used with Removable Needle (RN) syringes that are 250 µL and larger, or SampleLock syringes. Standard needle length is 2" / 51 mm. Removable (RN) needles are available in convenient six packs. Custom lengths and point styles are available.
-
SoftGrip Adjustable Volume Pipettes
HamiltonWide selection of ergonomic pipettes Completely autoclavable Guaranteed accuracy and precision All pipettes have color-coded plunger buttons and labels for easy volume identification. SoftGrip air-displacement pipettes are built from high quality, state-of-the-art materials designed to provide…
-
PRP-C18 Guard Columns
HamiltonGuard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…
-
Syringes & Accessories
HamiltonThe Hamilton barrel/plunger assembly is suitable for use with 10 uL 801RN syringe models. No needle included
-
Guard Cartridge Kit
HamiltonGuard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…
-
Microlab 600 Controller
HamiltonThe Microlab 600 Controller comes standard with the Basic functionality. For Advanced Controller functionality, the Basic to Advanced Controller Upgrade Kit (SD card) must be purchased separately.
-
Syringes
HamiltonThe Hamilton 1700 series 50 uL syringe is suitable for use with cemented needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a temperature rating of up to 10 to 50 degree C and pressure rating of up to 1000 psig.
-
Point styles 2 and 3 Standard 2” length Needles seat precisely to the zero graduation mark of the syringe. They are autoclavablewhen disassembled. They allow the use of different specification needles with the same barrel. The small ‘s’ next to the gauge number indicates…
-
Terasaki Dispenser
HamiltonThe Hamilton terasaki dispenser of 500 uL volume offers borosilicate glass and PTFE fluid path. It is suitable for use with gastight 1750 series syringe models.
-