LaMotte
-
-
Chlorine Test Kits
LaMotteDPD Tablet Octa-Slide (9859G42) Sufficient for 50 tests Employs DPD tablet method: EPA- accepted method for NPDWR Octa-Slide has color standards representing 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 and 3.0 ppm Cl Low Range Octet Comparator (9859H10) Employs DPD tablet…
-
Soil Test Kit, Model EL
LaMotteRapid test procedures and laminated color charts give low/medium/high concentrations for nitrogen, phosphorus and potassium (15 tests each) A pH indicator and color chart cover the range pH 4.0-9.0 (30 tests). A garden guide manual and soil handbook interpret test results and give lime and…
-
Direct Reading Titrator (9859K40 and K41) For determining high range chlorine in water Range of 0 to 200 ppm Cl2 in 4 ppm increments Sufficient for 50 tests at 200 ppm. Uses Iodometric reagent method.
-
DC1500 Chlorine Colorimeters
LaMotteThe DC1500 Chlorine Colorimeter Kit, ideal for both field and lab use, covers the entire critical chlorine range of 0-4 ppm with an MDL of 0.03 ppm. The Colorimeter is also EPA Compliant, (tablet version), using proper wavelength and DPD test method to meet EPA design specifications for NPDWR and…
-
Total Iron Test Kit
LaMotteOcta-Slide Comparator Tests total iron after any ferric iron is reduced to ferrous in the sample Sufficient for 90 tests Ferrous and ferric iron may be tested separately by eliminating the reduction step. Octa-Slide has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0…
-
Alkalinity Test Kits
LaMotteDirect Reading Titrator Method (9859A70 and A71) For determining total (T) alkalinity in water Range of 0 to 200 ppm as CaCO3 in 4 ppm increments Employs APHA Method 403. Sufficient for 50 tests at 200 ppm. Direct Reading Titrator (9859B10) For determining phenolphthalein (P)…
-
Colorimeter Reagent Kits
LaMottePre-mixed reagents for popular water treatment tests Pre-prepared reagent systems save labor Simplified methods reduce technician error Specific kits available for LaMotte’s SMART 3 Colorimeter and SMART Spectro Many kits use EPA compliant methodology Each reagent…
-
BrewLab® Pro Water Analysis Kit
LaMotteLaMotte introduces the new BrewLab® Pro water analysis kit. Designed with the professional brewer in mind, this kit measures 11 test factors which are important in the brewing process. Water is the most important ingredient for any brewer. The BrewLab® Pro helps you to make your best craft…
-
MANGANESE TEST KIT
LaMotteThe Low Range Manganese test kit measures Manganese levels at 0.05, 0.1, 0.2, 0.4, 0.6, 0.8 and 1.0 ppm using the Octa-Slide 2 Comparator.
-
Conductivity Solutions
LaMottePotassium chloride solutions TDS values are based on a 0.7 conversion from conductivity. Solutions can be used to standardize conductivity meters.
-
Cyanide Test Kit
LaMotteOctet Comparator For determining trace levels of free cyanide in water Octet comparator has color standards representing 0.00, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35 and 0.40 ppm Free CN - Sufficient for 50 tests
-
Ammonia Nitrogen Test Kits
LaMotteOctet Comparator Method (9859C70 and C71) For determining ammonia nitrogen in water using Nessler method Octet Comparator has color standards representing 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 ppm ammonia nitrogen Sufficient for 50 tests Octa-Slide Comparator Method…
-
Dissolved Oxygen Test Kits
LaMotteDirect Reading Titrator (9860J75 and J76) For determining dissolved oxygen in natural and treated waters Employs azide modification of Winkler method Range from 0 to 10 ppm with 0.2 ppm sensitivity Sufficient for 50 tests at 10 ppm Ideal for daily monitoring or D.O. meter…
-
Chlorine Test Strips
LaMotteTests 0-5 ppm Five intervals: 0, 0.5, 1, 3 and 5 50 strips per vial Unique range and sensitivity covers critical chlorine concentrations for many applications of food processing, water/wastewater treatment, education and other areas.
-
QAC Dual Range Test Strips
LaMotteThe New Dual Range QAC Test Strip takes care of ALL of your testing needs on ONE STRIP! Whether checking the concentration of your QAC solution or checking to ensure complete removal from treated surfaces, the new Dual Range QAC Test Strip DOES IT ALL! Chemically-treated test strips change…
-
Chromium Test Kit Reagent Refill
LaMotteOctet Comparator Method For determining hexavalent, trivalent, and total chromium Octet comparator has color standards representing 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2 and 1.5 ppm Cr Sufficient for 20 tests Test requires suitable hot plate, not included Reagent Refill only. …
-
Hardness Buffer Reagent
LaMotteFormula: Formula Weight: CAS Number: Synonym(s): Description: Ammonium Hydroxide and Ammonium Chloride in Water
-
The LaMotte Stormwater MS4 Kit has instrumentation and reagent systems to provide a preliminary screening of stormwater outflow, and to determine whether it is contributing to the overall pollutant load from precipitation events. Meets guidance as set forth by USEPA. Features …
-
Low Range Phosphate Test Kit
LaMotteThis LaMotte Phosphate test kit tests for low range Phosphate using the LRC Comparator. Range and sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43-. Applications: Environmental Education
-
Test Kit Components
LaMotteDirect Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL All-purpose…
-
Paper Iodine Test 200 Tests
LaMotteThe Iodine test papers are a convenient way to test Iodine in water with fast results. Range and sensitivity is 0, 30, 60, 120, 180 ppm.
-
Paper QAC Test 100 Tests
LaMotteChemically treated paper strips change to indicate sanitizer level. Strips and color chart are packaged in a waterproof plastic vial. 2951 is specifically formulated to read all types of QAC. Applications: Drinking Water, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water…
-
-
Peracetic Acid Kit
LaMotteThe hydrogen peroxide equivalence is 1 drop = 50 ppm. The peracetic acid equivalence can be modified to test different concentrations by using a different sample size. The result is a 1 drop = 6, 15, or 300 ppm equivalence.
-
Cadmium Test Kit
LaMotteOctet Comparator Method For determining cadmium in water using Dithizone method; commonly occurs from the deterioration of galvanized pipe Octet comparator has color standards representing 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8 and 1.0 ppm cadmium. For use only where organic matter is absent and…
-
This kit tests for nitrate nitrogen using tablet reagents and the Octa-Slide 2 Comparator. Range/sensitivity is 0, 1, 2, 4, 6, 8, 10, 15 ppm NO3 - -N Applications: Drinking Water, Environmental Education, Food and Beverage, Industrial Water Boiling and Cooling,…
-
Corrosion Control Test Kit
LaMotteNo. 7436-01 Determines corrosion conditions in water supplies which can introduce lead and heavy metals Supports a water supplier’s lead abatement program in drinking water Includes TDS pocket tester to meet EPA requirements for corrosion testing Packaged in a portable…
-
-
Turbidity Test Kit
LaMotteThis kit tests for turbidity using a turbidmetric card used match clarity to your sample. Range and sensitivity is 0, 20, 40, 60, 80, 100 JTU.
