TLC Plates
-
Silica Gel GHLF UNIPLATES
Miles Scientific (Analtech)These plates are 100% H20 resistant and are compatible with aqueous developing solvents. They are less rugged than the plates with organic binder but still provide improved handling and sample application compared to Silica Gel G UNIPLATES and are tough enough to write on with a soft pencil, if…
-
HPTLC SILICA GEL 60 RP-18 W 25 GLASS PALTES 10 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
Features Silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm; standard grade Outstanding wettability for precise colorization results, even with 100 % aqueous detection reagents Excellent separation…
-
Alox Aluminium Oxide Layers for TLC
MACHEREY-NAGELAluminium oxide, specific surface (BET) ~ 200 m 2 /g, mean pore size 60 Å; inert organic binder indicator manganese-activated zinc silicate available as glass plates, POLYGRAM® polyester sheets and ALUGRAM® aluminium sheets Recommended application: terpenes, alkaloids,…
-
Reversed Phase Octadecyl Silanized Silica Gel UNIPLATES
Miles Scientific (Analtech)These reversed phase TLC plates have been manufactured to be greater than 50% and less than 100% silanized. Because of this they are hydrophobic, but wettable. Features: 14% carbon content Acid stable (UV254) fluorescent indicator Glass backing 250um coating thickness 25…
-
Labels applied to all 4 sides of the plate. No sequence number duplicates. Exceptional print quality and resolution. Resistant to commonly used laboratory reagents. Resistant to temperature ranges of -80ºC to +52ºC. See Product Details below for bar code label specifications. Microplate…
-
TLC SILICA GEL 60 W F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
10 cm Latch-Lid Chromatotank
General Glass BlowingRequires less solvent to maintain equilibrium Gives excellent retention of solvent saturated chamber Holds two 10 x 10 cm plates The smaller cubic inch chamber allows for a faster and more uniform solvent-saturated atmosphere. Single molded tank has a flat ground top, beveled for…
-
Glass TLC Plates
MilliporeSigmaFor thin layer and preparative layer chromatography Ready-to-use Layer thickness 0.25 mm Allow safe spotting without layer damage Plates have a uniform, abrasion-resistant coating and a patented, inert, hard-layer binder that is chip and abrasion-resistant. F254 is a…
-
Rectangular Developing Tank
General Glass BlowingBeveled inside and outside to remove any sharp edges Raised ridge midway on the inside ends and bottom for developing two 20 x 20 cm plates or the equivalent Inside dimensions: 27 x 7 x 26 cm Supplied with flat glass lid, 30 x 10 x 3 cm Molded glass block of clear glass with…
-
TLC Silica Gel 60 RP-18 F254s
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
-
TLC SILICA GEL 60 RP-18 F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
HPTLC Silica gel 60 F254 Premium Purity
MilliporeSigmaThe plate is highly pure and exhibits minimal background, even with middle-polar solvent systems. Ideal for advanced pharmacopoeia applications, this high-performance plate keeps separations free of contamination. Its separation performance is an exact match to the related HPTLC plate product.…
-
TLC Plate Storage Rack
General Glass BlowingStore TLC plates without damaging delicate media Holds up to 10, 20 x 20 cm plates or equivalent number of narrower plates Racked plates may be air or oven dried Can be used with plates in either vertical or horizontal position Racks are also used for storage of dried layers…
-
TLC Developing Tank
DWK Life Sciences (Kimble)Constructed of sturdy molded glass bricks Withstands regular use for many years The tank’s clear sides allow for visual inspection of TLC plates up to 20 x 20 cm size. The top of the tank is ground flat to match the lids and the edges are beveled to remove any sharp edges. The bottoms are…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
HPTLC Silica Gel 60 F254
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
DURASIL Unmodified Standard Silica Layers for TLC
MACHEREY-NAGELFeatures Silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm Hard, water-resistant and wettable layers due to a special binder system No reversed phase tendency, more polar than SIL G Available as…
-
CHIRALPLATE Special Layer for TLC Enantiomer Separation
MACHEREY-NAGELFeatures Reversed phase nano silica impregnated with Cu(II) ions and a chiral selector (a proline derivative, DP 31 43 726 and EP 0 143 147) Separation based on ligand exchange, i. e. formation of ternary mixed-ligand complexes with the Cu(II) ions differences in the stability of the…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Millipore concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied;…
-
Features Silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g, particle size 5–17 µm available as glass plates with or without fluorescent indicator also available as ALUGRAM® Xtra aluminium sheets Excellent…
-
Baker-flex® Coated TLC Aluminum Oxide Sheets
Avantor - J.T.Baker®Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…
-
Glass-Backed HPTLC Plates
Miles Scientific (Analtech)High Performance UNIPLATES provide high resolution separations in less than five minutes with migration distances as little as 5 to 7 cm. These plates are prepared with high efficiency silica gel having a 10 micron average particle diameter and narrow particle size distribution. The adosrbent…
-
TLC Cellulose F
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
Designed for in vitro diagnostic assays. Flat bottom strips are designed to easily break apart and may be used in an "egg-crate" style strip holder that allows each individual well to be positioned back into the plate once broken. High binding surface binds medium (>10kD) and large biomolecules…
-
TLC Silica gel 60 F254
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
TLC Silica gel 60 F254
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
Silica Gel F TLC Plates
Miles Scientific (Analtech)Analtech’s flexible backed TLC plates offer the same exacting specifications as with the classic glass backed plates assuring batch-to-batch uniformity. Quality is controlled at each step in the manufacturing process — from incoming raw materials to outgoing packaging. Lighter…
-
TLC Cellulose
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…