TLC Plates

Compare Tool

Select up to 3 products

1 - 32 of 184
Sort
View
Show
  • Precoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…

  • Our NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative…

  • For use as reservoir tray with HTS Transwell Permeable SupportsTC-Treated for cell attachmentSame footprint as standard 24 well plate but with single rectangular wellSterilized by gamma radiation.

  • HPTLC Silica gel F254 GLP

    MilliporeSigma

    Features individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore silica found in…

  • Features High purity silica 60 with gypsum and a very small quantity of a polymeric organic binder softer than the standard silica layer, i. e. spots can be scratched and the layer absorbs faster Available as glass plates with or without fluorescent indicator Recommended for the…

  • Silica Gel HL UNIPLATES

    Miles Scientific (Analtech)

    These are the most rugged silica gel plates available. They not only ease handling and sample application, but also permit the use of up to 80% water in the developing solvent without loss of adherence of the adsorbent layer to the glass plate. Organic binder plates are recommended for all TLC…

  • For analysis of polar substances The organic sorbent cellulose is particularly suitable for the separation of hydrophilic substances by partition chromatography. EMD Millipore cellulose plates include classical TLC grade or HPTLC plates for demanding high-performance separations: TLC…

  • HPTLC Cellulose

    MilliporeSigma

    Cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…

  • RP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…

  • Glass-Backed HPTLC Plates

    Miles Scientific (Analtech)

    High Performance UNIPLATES provide high resolution separations in less than five minutes with migration distances as little as 5 to 7 cm. These plates are prepared with high efficiency silica gel having a 10 micron average particle diameter and narrow particle size distribution. The adosrbent…

  • TLC Cellulose F

    MilliporeSigma

    Cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…

  • EMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…

  • Pre-scored glass plates fold into smaller formats with just one easy snap of the fingers. HS Code: 3822 00 00

  • Features Nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 2–10 µm Outstanding hardness and abrasion resistance due to an optimized binder system Increased separation efficiency due to an optimized…

  • Features Base material: silica 60, specific surface (BET) ~ 500 m 2 /g mean pore size 60 Å specific pore volume 0.75 mL/g particle size 5–17 μm pH stability 2–10 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV…

  • Silica Gel G UNIPLATES

    Miles Scientific (Analtech)

    Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulfuric acid charring visualization.These plates are commonly scraped from the glass backing to isolate separated components for other…

  • Avicel F UNIPLATES

    Miles Scientific (Analtech)

    These plates are coated with AVICEL microcrystalline cellulose manufactured by the American Viscose division of FMC Corp. The adsorbent consists of regenerated alpha cellulose particles of nearly spherical shape and 50 micron mean diameter.

  • Rectangular Developing Chambers

    General Glass Blowing

    The single most useful chamber for the TLC laboratory is a sturdy, molded-glass block of clear glass with flat surface walls, ground lip of uniform flatness, beveled inside and outside to remove any sharp edges. There is a raised ridge midway on the inside ends and bottom of the jar. Inside…

  • Features Silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g, particle size 5–17 µm available as glass plates with or without fluorescent indicator also available as ALUGRAM® Xtra aluminium sheets Excellent…

  • Clear polystyrene Surface for cell attachment Sterile Individually labelled wells Lid allows gas exchange Disposable 1 plate with lid sealed in a paper and plastic package Shelf life: 3 years after produced Non pyrogenic: This product is controlled for < 0.5 EU/mL

  • TLC Silica gel 60

    MilliporeSigma

    Classic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.

  • Aluminiumoxide plates are used to analyze basic and neutral compounds at different pH levels. Depending on the pH range in question, professionals can choose between two kinds of aluminum oxide plates. Under aqueous conditions, basic aluminum oxide plates are best for separating basic compounds,…

  • EMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…

  • Glass TLC Plates

    MilliporeSigma

    For thin layer and preparative layer chromatography Ready-to-use Layer thickness 0.25 mm Allow safe spotting without layer damage Plates have a uniform, abrasion-resistant coating and a patented, inert, hard-layer binder that is chip and abrasion-resistant. F254 is a…

  • These plates allow users to separate samples that vary greatly in size – from grams down to milligrams. Available with or without a fluorescence indicator, PLC plates has 1.5 mm thickness. They also use the same proven EMD Millipore silica-binder technology as in analytical TLC plates. To isolate…

  • Chromatography TLC Sprayers

    SP Wilmad-LabGlass

    When using thin layer or paper chromatography (TLC), these borosilicate glass atomizers are used for spraying chromogenic reagents. Complete unit consists of spray head, flask, and LG-1004 clamp. The air inlet tube has an opening to release pressure and stop spraying. All joints are Standard Taper 24/40.

  • RP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…

  • TLC Cellulose F

    MilliporeSigma

    These plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…

  • Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…

  • Synonyms: TLC cards Silica gel

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.