Hardware, General Chromatography
-
Symbol: Mg Matrix: Hydrocarbon Oil Size: 50 g
-
-
CHROMAFLEX® Flow Adapters
DWK Life Sciences (Kimble)Flow adapters improve chromatogram resolution by delivering the sample and buffer directly to the top of the gel bed. This protects the gel bed from disruption during sample loading and eliminates any dead volume above the gel bed. Flow adapters are recommended when using buffer gradients,…
-
-
-
Pure Grade Standards for AA and ICP-OES: Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certi cate Impurities reported at ppm level All Standards are prepared and certified under ISO Guide 34 and ISO 17025 …
-
Consists of a selection of O-Rings for the Optima 2000/4000 injector assembly.
-
Quartz 2mm Bore Injector for ELAN DRC
PerkinElmerReplacement 2mm bore quartz injector with ball joint. For use with pass-through injector support part no. WE023951. Standard on the ELAN DRC.
-
-
Valve, Outlet, for Agilent 1260 Infinity LC Cap/Nano/SFC Pumps
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
NITRO-GEN nitrogen generator, 0-20 L/min
OrganomationThe NITRO-GEN line of nitrogen gas generators is designed for general lab purposes such as blowdown evaporation. The NITRO-GEN is ideal for labs looking to convert compressed air to high purity nitrogen quickly and inexpensively. At under 20 lbs, the NITRO-GEN is easy to install and move as needed.…
-
Matrix: 5% HNO3 Contents: 1,000 mg/L: As, Ba, Be, Cd, Cr, Co, Cu, La, Pb, Li, Mn, Ni, Sc, Sr, V, Y, Zn Volume: 500 mL
-
Vespel blend rotor seals have an operating pH range from 0 to 10. Tefzel blend and PEEK blend rotor seals have a pH range from 0 to 14. Strong oxidizing acids such as concentrated nitric and sulfuric are not compatible with PEEK. Don't Risk using imitation parts. Only Genuine PerkinElmer authorized…
-
Nupro Plug Valves
SwagelokFast acting, 1/4 turn shutoff Simple, compact design Design consists of body, plug assembly and handle. Plug and O-ring seals are TFE coated to provide lubrication between plug assembly and the body bore. Valve features very low torque operation. Intermediate valve positions allow forward…
-
FlashPure EcoFlex cartridges are packed with quality silica designed to help maximize cost and performance on any flash purification instrument. Large selection of cartridge sizes Several stationary phases available Luer lock inlet and Luer slip outlet Non-RFID suitable on any…
-
VHP Fittings
Agilent TechnologiesAgilent's 1200 bar removable fitting (for 1/16 in od capillaries) consists of a stainless steel screw, an internal stainless steel ferrule and a front ferrule in PEEK. The fitting can be used throughout the flow path, but because it can be re-used without losing tightness, it is especially…
-
-
The multi-element V-23 Wear Metal Standards for detection of metal in engine oil are available from PerkinElmer.
-
Instrument Calibration Standard 2: 100mL
PerkinElmerEnvironmental Standard for the NexION Standard Mode. 5% HNO3/tr Tartaric Acid/tr HF. 100 µg/mL: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Se, Sn, Sr, Ti, Tl, V, Zn. 125 mL.
-
-
SPE Tube Adapter
MilliporeSigmaTube adapters serve many purposes. They can be used to stack one SPE tube on top of another to provide different selectivities. A larger empty syringe barrel can be stacked on top of a smaller SPE tube to act as a larger load reservoir. Or, they can serve as an adapter for positive pressure methods…
-
Silica-free, bonded polymeric material—no unwanted secondary silica interactions, even with basic compounds. High surface area—higher loading capacity compared to silica-based sorbents. Stable over a wide pH range (0–14)—won’t hydrolyze under extreme conditions. …
-
Standard THGA Graphite Contact Cylinders, 1 Pair
PerkinElmerPerkinElmer has over four decades of experience in the design/development of graphite furnace systems and materials. The proper performance, maintenance and serviceability of our graphite furnace systems can be assured only through the use of genuine PerkinElmer supplied graphite components such as…
-
V-Solv ICP Solvent - 5 Gallon
PerkinElmerV-Solv ™ ICP Solvent 5 gallon is a proprietary solvent that is used for diluting oil and other organic liquids for analysis by ICP and ICP-MS. Use V-Solv ™ as a matrix blank and as a diluent for your calibration standards and samples for outstanding nebulization characteristics. V-Solv ™ ICP…
-
-
-
Alumina Injector, 0.80 mm i.d for Optima 8x00
PerkinElmerThe PerkinElmer Alumina Injector, 0.80 mm i.d is for use with the Optima 8x00 ICP-OES. Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with less volatile organic solvents, e.g., xylene.
-
Sapphire Injector 1.8 mm (Bayonet) in PFA Base
PerkinElmerSapphire injector, bayonet mount. HF-resistant. Used for high matrix geochemistry and HF applications where low ppt Al is not required.
-
-
Quartz SUPRASIL Semi-micro with PTFE Lid
PerkinElmerSemi-micro cells have the same outside dimensions as the macro cells but the cell walls have been thickened slightly, limiting the interior sample chamber width to 4 mm. This reduces the sample requirements by 60%. Each package contains two cells with two clear windows each.
-
-
Caffeine Quantitation Test Kit
PerkinElmerIdeal for a variety of analyses, this single quadrupole detector brings the unsurpassed sample insight of mass spectrometry to liquid chromatography applications. The Flexar SQ 300 MS ™ is an integral part of the powerful and exible Flexar LC product line. It features a revolutionary…