Accessories, Filters, Supplies
-
XX6700P01
MilliporeSigmaDispensing pressure vessel, 1 gallon Dispensing pressure vessels hold liquid for filtration through Millipore pressure-operated filter holders when connected to an external pressure source. Type 316 stainless-steel body and fittings; Viton gaskets and O-rings; molded neoprene rubber…
-
Ultra Clean Moisture Filter for GC and GC/MS
PerkinElmerThe easy to use leak-tight cartridge system enables rapid change of exhausted cartridges without interrupting supply or system operation. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and…
-
Hose assemblies for connecting Fuel, Air and Nitrous Oxide from supply to instrument.
-
-
For supporting funnels, Gooch crucibles, filter tubes, etc., in filtration assemblies Particularly suitable for Buchner and fritted glass funnels, porcelain filters without head pieces and for reverse flow cleaning of filter crucibles Adapters will withstand autoclaving Taper angle in all…
-
Vented In-Line Filter Holder, Stainless Steel
Advantec MFS47mm filter diameter Available in type 304ss or 316ss Filter liquids or gases at point-of-use This 47mm in-line holder (model KS47) is available in both type 304 or 316 stainless steel. The PTFE coated support screen prevents sticking of the membrane during autoclaving. The…
-
Ultra Clean Oxygen Filter for GC and GC/MS
PerkinElmerThe easy to use leak-tight cartridge system enables rapid change of exhausted cartridges without interrupting supply or system operation. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and…
-
-
Polysulfone Vacuum Filter Holders
Advantec MFS47mm Filter Graduated Funnels: 300mL, 500mL, 800mL Autoclavable Advantec’s Polysulfone 47mm Filter Holders are an economical alternative to glass vacuum holders. The durable polysulfone plastic construction is chemically resistant and can withstand mishandling. The recessed…
-
-
Stainless Steel Gas In-Line Filter Holders
Advantec MFSThreaded locking ring enables filter changes without disconnecting the gas lines. Dual support screens protect the membrane filter from reverse pressure surges and allow forward and reverse flow. Tighten by hand only - hand torque maximum is 15 lbs/in. Type 304ss body and support screen.…
-
Neoprene Filter Adapters
ChemglassNeoprene filter adapters are designed to fit between a filtering funnel and a flask. For use with Buchner funnels, Gooch crucibles, filter tubes, etc. Can be used individually or nested with adjacent sizes. Eliminates the boring of rubber stoppers and the difficulties of inserting and removing…
-
-
Stainless Steel Vacuum Manifolds
GVS Filter TechnologyVacuum manifold used for filtration and analysis of liquid samples Stainless steel filter funnel manifold, for use with microbiology monitors, analytical funnels and general filtration. Features and Benefits Durable Stainless Steel construction for easy cleanup and…
-
Rapid-Flow™ Sterile Filter Storage Bottles
Thermo Scientific NalgeneSave time and minimize contamination with radiation-sterilized Thermo Scientific™ Nalgene™ Rapid-Flow™ Filter Storage Bottles. Use with Nalgene Bottle-Top Filters or as replacement/extra receptacles for Nalgene Tissue Culture and Sterilization Filter Units. Excellent as single-use…
-
The easy to use leak-tight cartridge system enables rapid change of exhausted cartridges without interrupting supply or system operation. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and…
-
Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
Air Filter for the Fan of the Main Power Supply
PerkinElmerAir filter is for the fan of the main power supply.
-
In-Line Solvent Filter System for Stainless Steel pumps
-
Cell Strainers
Argos TechnologiesCell Strainers Extended tab for easy handling Argos cell strainers offer a simple, ready to use method for securing single-cell suspensions. Available in filter mesh diameters of 40, 70 and 100µm. They are compatible with 50mL centrifuge tubes and feature color-coded…
-
In-Line Filter Trap
PerkinElmerGas contacts only glass, metal and the adsorbents for purity. The Drierite ® indicator and molecular sieve 5A are packed in glass protected by an outer plastic tube in the event that the glass breaks. Unique loading design allows operation in any orientation without channeling. Designed for GC…
-
Ultra Clean Wall-mounting Bracket Set
PerkinElmerCartridge systems make changing gas filters quick and easy. A base plate allows cartridges to be exchanged without introducing oxygen. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and…
-
-
The PolyScience Air Filter with Frame
PerkinElmerFor use with the PolyScience® WhisperCool™ Refrigerated Chiller 240 V, 50 Hz, 12.2 A part number N0772045 and the PolyScience® WhisperCool™ Refrigerated Chiller 208-230 V, 60 Hz, 12.2 A part number N0772046
-
GE Filter Holder
GVS Filter TechnologyPolypropylene body and support Broad chemical compatibility range Available in 25 mm and 47 mm sizes Autoclavable Filter holders can also be used for aseptic sampling of liquids or gases at point-of-use or when samples must be collected and analyzed on site. The 25 mm filter is used…
-
Replacement Air Filter Element for Filter Assembly N0775325
-
Cartridge systems make changing gas filters quick and easy. A base plate allows cartridges to be exchanged without introducing oxygen. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and…
-
Kit Of 8 Vacuum Caps And (1) Tubing Adapter For Reusable Filter Holders
Thermo Scientific NalgeneAdapter kit for Reusable Filter Holders Consists of 8 vacuum caps and a tubing adapter
-
Oxygen Stainless Steel Trap
PerkinElmerSpring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
-
Cell Strainers
BiologixMade of sturdy polypropylene and strong nylon mesh Three different pore sizes available: 40μm, 70μm, or 100μm, strainers are color-coded according to pore size for convenience Fits perfectly into Biologix 50mL Centrifuge Tubes Gamma radiation sterilized, non-pyrogenic
-
Safe Glass Moisture Trap
PerkinElmerIn-line moisture trap. Drierite indicating agent and MolecularSieve 5A are packed in glass which is enclosed in a safety plastic tube in the event the glass breaks. Unique loading design allows operation in any orientation without channeling. For use with pressures up to 100 psig. Designed for use…