Moisture Trap

Compare Tool

Select up to 3 products

Moisture Trap
1 - 32 of 103
Sort
View
Show
  • Ace Glass

    For solvents heavier than water. Used in the method of quantitative separation and determination of glycol mixture by azeotropic distillation described in Analytical Chemistry, Vol. 29, No.1, Page 100. Capacity is 121/2mL, graduated in 0.1mL. Joints are standard taper 24/40.

  • …the glass indicator section of the filter is sealed, so the gas flow is secure even if the glass is broken. Removes Moisture The Moisture trap removes water from inert gases, air or hydrogen to less than 20 ppb at flow rates up to 2 L/min. The trap has a capacity for water of 15 g.

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • …detectors that require high-purity gases. Recommended for ELCD and ECD systems in which moisture and contamination are a problem. Trap is shipped active and purged with nitrogen. It is recommended that you purge the trap with the gas you plan to use. Approximate dimensions: 13/8 in. W x 10 1/4 in. H…

  • MilliporeSigma

    …humidity.Note: Not for use with carrier gas streams.Dimensions: •400 cc Traps: 17 1/2 in. (44.4 cm) long x 2 in. (51 mm) diameter Synonyms: ECONOMY MOISTURE-REMOVING TRAP, 400CC, 1/4IN FITTINGS Application: Moisture trap may be used to remove all the solvent present, during the extraction…

  • Unique adapter used in place of a Dean & Stark Moisture Test Receiver. Simply add a condenser to top standard taper outer joint, any graduated funnel from 125mL to 2000mL to bottom standard taper inner joint, attach sample flask to inner side arm joint and you have a moisture test receiver.

  • Unique adapter used in place of a Dean & Stark Moisture Test Receiver. Simply add a condenser to top outer joint, any graduated funnel from 125mL to 2000mL to bottom inner joint, attach sample flask to inner side arm joint and you have a moisture test receiver.

  • Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen Reduces water to less than 15 ppb Maximum operating pressure: 250 psi (1,724 kPa) Maximum flow: 1.25 L/min

  • Reduces water to less than 10 ppb; indicator changes from yellowish-green to blue at 5% relative humidity Prepurged for fast stabilization Reduces noise from high-sensitivity detectors Heavy-walled glass body prevents oxygen and water infusion 10 µm frit prevents microparticulate…

  • SP Wilmad-LabGlass

    Made of borosilicate glass, these Bidwell-Sterling moisture traps are calibrated "to contain" (TC) at 20°C and are used for determining moisture in samples by distilling with an immiscible liquid. Consist of vapor tube, return tube, round bottom graduated tube, and Standard Taper 24/40…

  • quick-ship

    SP Wilmad-LabGlass

    Calibrated "to contain" at 20°C, these borosilicate glass moisture traps are used for the determination of water in various materials by distillation with an immiscible solvent. They consist of a full length Standard Taper inner joint for vapor tube connection to distilling flask and a…

  • Agilent Technologies

    …band of Indicating Molecular Sieve 4Å Available in 70 cc, 100 cc and 250 cc sizes Heavy wall borosilicate glass tube — no moisture diffusion Refillable The 100 cc unit will treat 10 standard “A” cylinders with up to 30 ppm water or 16.3 grams to less than…

  • Agilent Technologies

    Ultra-high capacity for moisture Capacity 130 g H2O Pressure up to 250 psig Reduce H2O to ≤5 ppb 750 cc gas purifiers Refillable Suitable for bulk purification applications or where several instruments are plumbed from a single gas source. Agilent…

  • emp Biotech

  • …5A efficiently removes moisture and heavy hydrocarbons from compressed air, electrolytically produced hydrogen, house nitrogen, or other gases with high moisture or hydrocarbon content.Dimensions: •200 cc Trap: 26 1/4 in. (67 cm) long x 1 in. (2.5 cm) diameter •750 cc Trap: 18 in. (45.7 cm) long x…

  • …5A efficiently removes moisture and heavy hydrocarbons from compressed air, electrolytically produced hydrogen, house nitrogen, or other gases with high moisture or hydrocarbon content.Dimensions: •200 cc Trap: 26 1/4 in. (67 cm) long x 1 in. (2.5 cm) diameter •750 cc Trap: 18 in. (45.7 cm) long x…

  • …5A efficiently removes moisture and heavy hydrocarbons from compressed air, electrolytically produced hydrogen, house nitrogen, or other gases with high moisture or hydrocarbon content.Dimensions: •200 cc Trap: 26 1/4 in. (67 cm) long x 1 in. (2.5 cm) diameter •750 cc Trap: 18 in. (45.7 cm) long x…

  • …Indicating Moisture Traps are designed to remove water, oil, and organics from gases employed in, but not limited to, gas chromatography. Refillable moisture traps are constructed from Lexan brand polycarbonate tubing. Lightweight, chemically resistant and of superior strength when compared to traps

  • …these borosilicate glass Bidwell-Sterling moisture traps collect liquefied vapor. They feature a connection between top of vapor tube and graduated tube. This construction allows excess solvent to return to flask with minimal chance of condensed moisture return. Standard Taper 24/40 inner and outer…

  • Click-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in. There is no need for…

  • Click-On Traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2cm) Note: Replacement trap only—fittings sold separately.

  • Agilent Technologies

    Adsorbent refiles for hydrocarbon/moisture traps allow continued removal of extremely low levels of both moisture and hydrocarbons. Refill supplies material for two recharges for HMT trap. Agilent Technologies products are intended for sale/shipment within the US only. International customers…

  • Agilent Technologies

    …polar phases. The Agilent OT3 Trap contains a highly active, metal-containing, scrubbing material in an inert, aluminum body. This material removes 500 mL oxygen from a gas stream to less than 15 ppb. Additionally, up to 2 grams of moisture can be removed by this trap without affecting the oxygen…

  • Agilent Technologies

    Contains Molecular Sieve 5 Angstrom, 45/60 mesh Traps can be reconditioned by heating at a minimum of 350°C, with flow for 6 hours. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies…

  • …and provides greater working capacity] Synonyms: Supelpure® O 1/4 INCH Application: Two cascade columns of Molecular Sieve 5A Moisture Trap and Supelpure®-O Oxygen/Moisture Trap was used to purify ethylene. Legal Information: Supelpure is a registered trademark of Sigma-Aldrich Co. LLC

  • …greater working capacity] Synonyms: SUPELPURE-O, 750CC, 1/4IN FITTINGS Application: Supelpure®-O Oxygen/Moisture Trap along with Molecular Sieve 5A Moisture Trap was used as the two cascade columns required for the purification of ethylene, in an experimental study based on using…

  • …and provides greater working capacity] Synonyms: Supelpure® O 1/8 INCH Application: Two cascade columns of Molecular Sieve 5A Moisture Trap and Supelpure®-O Oxygen/Moisture Trap was used to purify ethylene. Legal Information: Supelpure is a registered trademark of Sigma-Aldrich Co. LLC

  • Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.

  • The Agilent Technologies in-line gas purifier oxygen/moisture trap is suitable for use with chromatography or spectrometry system models. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • Finish: Crimp Top Cap with Septa

Compare Tool

Select up to 3 products