Gas Chromatography Columns

Compare Tool

Select up to 3 products

HomeAll Products

Columns Gas Chromatography Columns

1 - 32 of 980
Sort
View
Show
  • Equivalent to USP G27 and G36 phases Temperature range -60°C to 330/350°C

  • Equivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C

  • OPTIMA® WAX Capillary columns for GC Features Polyethylene glycol 20 000 Da USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax,…

  • Equivalent to USP G42 phase Temperature range 40°C to 320°C.

  • Many laboratories analyzing organochlorine pesticides struggle with breakdown and adsorption of endrin, DDT, and methoxychlor caused by active sites throughout the analytical system. Siltek passivation technology enables these columns to offer unsurpassed inertness and the highest responses for…

  • Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAMEs,…

  • Temperature range -60oC to 400 oC Equivalent to USP G27, G36 phases

  • nonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. …

  • Application: This non-polar general purpose column provides primarily a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. USP Code: This column meets USP G27 and G36 requirements. Phase: Bonded Poly(5% diphenyl/95%…

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • General purpose column having a PTFE stopcock and a top Rodaviss® outer joint. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number…

  • Temperature range -20oC to 240 oC

  • DB-HeavyWAX GC Columns

    Agilent Technologies

    The Agilent J&W DB-HeavyWAX Polyethylene Glycol (PEG) is a high temperature WAX column that can operate at higher maximum temperatures compared to standard WAX columns. The higher maximum temperature limit allows for shorter run times, providing a lower cost per test. The column provides…

  • nonpolar phase; Crossbond dimethyl polysiloxane MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. General-purpose columns for solvent…

  • SCOT column is a support-coated open tubular column prepared by a special process.

  • Equivalent to USP G27 and G36 phases Temperature range -60°C to 350°C

  • CAM

    Agilent Technologies

    Base deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing.

  • Though highly stabilized, it is impossible to guarantee that no particles will dislodge from the column wall. When used in valve-switching applications, the use of a particle trap can prevent the scarring of rotors.

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • Temperature range 40oC to 250 oC

  • Elite-17ms columns are for confirmation analysis and have excellent inertness for active compounds

  • Our new line of Velocity fused silica columns yield exceptional performance for general Gas Chromatography (GC) applications without the cost associated with gas chromatography and mass spectrum analysis. PerkinElmer Velocity columns are excellent for standard daily test applications. They combine…

  • low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…

  • midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropylmethyl polysiloxane…

  • 100% divinylbenzene Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The…

  • Equivalent to USP G3 phase Temperature range 40°C to 320°C

  • Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAMEs,…

  • Temperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.

  • polar phase; Crossbond polyethylene glycol Rtx-Wax columns are the most inert and efficient PEG columns currently available. The extended operating temperature range allows analysis of compounds having a wide volatility range and ensures low bleed at temperatures as high as 250°C.…

  • Reservoir for use with CG-1199 and CG-1200 columns. Reservoir has a top 35/20 socket joint for use with CG-1201 flow control adapter and the listed size lower ball joint.

  • Temperature range 40oC to 300/320 oC