Miscellaneous Omaha Oakton

Miscellaneous Omaha Oakton

Products (53)

Compare Tool

Select up to 3 products

  • Thermocouple Probe

    Thermocouple probes operate on the principle that an electromagnetic force (emf) is generated when heat is applied to the junction of two dissimilar metals (sending junctions). At the other end of the wires, usually as part of the input instrument, is another junction called the reference junction....

  • Digi-Sense Thermistor Probe

    Time constant is the time required to reach 63.2% of the new reading. To determine how long it will take to reach 99% of the new reading multiply the time constant by five. The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the...

  • Thermistor Probe

    Time constant is the time required to reach 63.2% of the new reading. To determine how long it will take to reach 99% of the new reading multiply the time constant by five. The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the...

  • Penetrationation Probe

    the temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the handle depending on exposure time, application, and handle material. ABS handles are rated to 220°F (104°C); PVC handles are rated to 200°F (93°C); Stainless Steel handles are...

  • T/C Probe, Heavy Duty Penetration K

    Penetration Probes offer a pointed tip style for penetration into hard and semisolid materials. These thermocouple probes were designed to measure any general-purpose or liquid immersion application. All thermocouple probes include a 5-ft PVC coiled cord with strain relief that protects from...

  • pH Probe

    Oakton

    The Oakton double junction pH probe is suitable for use with all Oakton pH meters. Outstanding value at an economical cost Compatible with all Oakton brand pH meters Ideal for dirty samples Impact resistant Double junction type

  • TC, Probe, Hvy. Duty, 12"  K

    These thermocouple probes were designed to measure any general-purpose or liquid immersion application. All thermocouple probes include a 5 foot PVC coiled cord with strain relief that protects from repeated flexing and tugging. Ergonomic, easy-grip (5 inches in length), glass-filled nylon handle...

  • ATC Probe

    Oakton

    Provides ATC for most current Oakton pH meters. Ensure optimal pH and ion measurement with ATC probes. Corrosion-resistant stainless steel 30 KO thermistor features durable polymer handle and 3.3 ft (1-m) cable. Probes measure 88-mm L x 3-mm dia; handle adds another 67 mm to the total length....

  • Specialty Probe

    The Oakton type T general purpose specialty probe features color coded ANSI miniconnectors, such as type J in black color, type K in yellow color and type T in blue color. This heavy-duty probe with a length of 29 Inch ensures extra-long penetration for soft and semi-soft materials.

  • Conductivity Probe

    A variety of conductivity probes for any application. Choose a cell constant compatible with your application. Varying cable lengths available. Keep your multiparameter meters up and running with replacement conductivity probes. Update, upgrade, or replace to get the best out of your Oakton...

  • Conductivity Probe

    A variety of conductivity probes for any application. Choose a cell constant compatible with your application. Varying cable lengths available. Keep your multiparameter meters up and running with replacement conductivity probes. 2-Cell Electrode, K=0.1 Varying cable lengths available 1 year warranty...

  • Digi-Sense Conductivity Probe

    A variety of conductivity probes for any application. Choose a cell constant compatible with your application. Varying cable lengths available. Keep your multiparameter meters up and running with replacement conductivity probes. Update, upgrade, or replace to get the best out of your Oakton...

  • Digi-Sense Surface Probe

    The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the handle depending on exposure time, application, and handle material. ABS handles are rated to 220°F (104°C); PVC handles are rated to 200 deg F (93 deg C); Stainless Steel...

  • Digi-Sense Surface Probe

    The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the handle depending on exposure time, application, and handle material. ABS handles are rated to 220°F (104°C); PVC handles are rated to 200 deg F (93 deg C); Stainless Steel...

  • Thermocouple Probe

    Thermocouple probes operate on the principle that an electromagnetic force (emf) is generated when heat is applied to the junction of two dissimilar metals (sending junctions). At the other end of the wires, usually as part of the input instrument, is another junction called the reference junction....

  • Digi-Sense Thermocouple Probe

    Thermocouple probes operate on the principle that an electromagnetic force (emf) is generated when heat is applied to the junction of two dissimilar metals (sending junctions). At the other end of the wires, usually as part of the input instrument, is another junction called the reference junction....

  • Digi-Sense Thermistor Probe

    Time constant is the time required to reach 63.2% of the new reading. To determine how long it will take to reach 99% of the new reading multiply the time constant by five. The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the...

  • Digi-Sense Thermocouple Probe

    Thermocouple probes operate on the principle that an electromagnetic force (emf) is generated when heat is applied to the junction of two dissimilar metals (sending junctions). At the other end of the wires, usually as part of the input instrument, is another junction called the reference junction....

  • Digi-Sense Thermistor Probe

    Time constant is the time required to reach 63.2% of the new reading. To determine how long it will take to reach 99% of the new reading multiply the time constant by five. The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the...

  • Thermocouple Probe

    Heavy-Duty Extra-Long Penetration Probes Are Designed For Soft and Semi-Soft Materials. Response Time: 2 seconds or greater ABS handles provide a light weight design for ease of use along with durability Probe handles feature a strain relief spring that protects the cable connection against damage...

  • pH Probe

    Oakton

    Oakton combination electrodes are available in a variety of styles to meet the needs of your application. Epoxy electrodes are impact resistant and provide excellent durability for field applications. Glass electrodes withstand aggressive chemicals. Choose junction and tip style based on the needs...

  • Digi-Sense Thermistor Probe

    Time constant is the time required to reach 63.2% of the new reading. To determine how long it will take to reach 99% of the new reading multiply the time constant by five. The temperature range is for the probe tip only. The handle material may be affected if the probe is rated higher than the...

  • Digi-Sense Thermocouple Probe

    Thermocouple probes operate on the principle that an electromagnetic force (emf) is generated when heat is applied to the junction of two dissimilar metals (sending junctions). At the other end of the wires, usually as part of the input instrument, is another junction called the reference junction....

  • Digi-Sense Thermocouple Probe

    Thermocouple probes operate on the principle that an electromagnetic force (emf) is generated when heat is applied to the junction of two dissimilar metals (sending junctions). At the other end of the wires, usually as part of the input instrument, is another junction called the reference junction....

Compare Tool

Select up to 3 products