  • Chlorine And Chloramines Test Kits

    Direct Reading Titrator (9859K40 and K41) For determining high range chlorine in water Range of 0 to 200 ppm Cl2 in 4 ppm increments Sufficient for 50 tests at 200 ppm. Uses Iodometric reagent method.

  • Detergents CHEMets Kit, Range: 0-3 ppm

    Detergents can be introduced into the water supply by industry, soap manufacturers, and private households. Environmental analysts often include a determination of anionic detergents when assessing surface water pollution. The Methylene Blue Method References: USEPA Methods for Chemical Analysis of...

  • pH Test Method: colorimetric with color card  and sliding comparator - MQuant®

    Designed for accurate, reliable, and quick assessment of water pH levels, the MQuant colorimetric test kit offers a precise solution for water quality monitoring. It operates on a colorimetric method with a color card and sliding comparator, enabling users to visually match the color produced by the...

  • NANOCOLOR BOD5 (Winkler)

    Tube test for the determination of BOD5 in Winkler-bottles. Precise rapid tests for all kind of water and waste water analysis. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: BODs - 2–3000 mg/L O2

  • Spectroquant® Hydrogen Peroxide Test Method: photometric

    UN Number: UN3316

  • Caustic Kit

    In this Sodium Hydroxide Test Kit a sample is reacted with barium to precipitate any carbonates, then is titrated with a standard acid to the phenolphthalein endpoint. Range/sensitivity is 0-10%/0.2% NaOH # Tests (# Rgts) is 50 at 10% (4) The Sodium Hydroxide Test Kit contains the following: (30...

  • NANOCOLOR Fluoride 2

    CTL Scientific

    Tube test for the determination of Fluoride. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Fluoride - 0.1–2.0 mg/L F?

  • Legionella Single Test Kit

    The Legionella Single Test Kit detects the presence of Legionella in a filtered water sample.It contains everything you need to perform one test with the highest accuracy. With results in 30-35 minutes (including sample prep-time), the test allows for immediate understanding and response to the...

  • NANOCOLOR Silica

    CTL Scientific

    Standard test for the determination of Silica. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers. Measuring range: Silica - 0.01–10.0 mg/L Si, Silica - 0.02–10.0 mg/L SiO2

  • Sodium Test Kit

    Direct Reading Titrator For determining levels of sodium in natural and treated waters Range 0 to 500 ppm sodium in 10 ppm increments Test requires three titrations: one to determine bicarbonate and carbonate ions; one to determine sulfate and chloride ions; and one to determine calcium and...

  • Spectroquant® Phenol Cell Test Method: photometric

    UN Number: UN3316

  • Chlorine Bleach Test Kit

    Applications: Industrial Water Boiling and Cooling, Water and Wastewater This test kit measures for Chlorine Bleach using the Direct Reading Titrator method. Range/sensitivity is 00-10%/0.2% Cl.

  • Alkalinity Titrets® Kits

    Methods The alkalinity of water is a measurement of its buffering capacity. Alkalinity of natural waters is typically a combination of bicarbonate, carbonate, and hydroxide ions. Sewage and wastewaters usually exhibit higher alkalinities due to the presence of silicates and phosphates. Alkalinity...

  • NANOCOLOR COD 4000

    CTL Scientific

    Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD - 400–4000 mg/L O2

  • TB 250 Portable Turbidimeter

    For measuring water turbidity (cloudiness) according to either EPA or ISO Standards Easy Calibration and Operation Auto Ranging from 0-1100 NTU Simple 5 key operation Signal Averaging for stable and accurate readings Long Battery and Bulb Life Portable for use either in the lab or field Choose TB...

  • NANOCOLOR Nitrite 2

    CTL Scientific

    Tube test for the determination of Nitrite. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Nitrite - 0.003–0.460 mg/L NO2-N, Nitrite - 0.02–1.50 mg/L NO2?

  • NANOCOLOR COD 40

    CTL Scientific

    Tube test for the determination of COD. Precise rapid tests for all kind of water and waste water samples according to ISO 15705. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: COD - 2–40 mg/L O2

  • Spectroquant® Cyanuric Acid Test Method: photometric

    Spectroquant® Cyanuric Acid Test Method: photometric

  • NANOCOLOR Chlorine dioxide 5

    Tube test for the determination of Chlorine dioxide. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with Macherey-Nagel NANOCOLOR photometers. Measuring range: Chlorine dioxide - 0.15–5.00 mg/L

  • Chloride Test Kits

    EPA-accepted method for NPDWR and NPDES Employs modified APHA Argentometric method Range of 0 to 50 ppm Cl in 1 ppm increments Sufficient for 50 tests Range of 0 to 200 ppm Cl in 4 ppm increments Sufficient for 50 tests at 200 ppm Employs Argentometric method

  • Ammonia Vacu-vials Kit, Range: 0-14.0 ppm

    Low-level ammonia nitrogen may be naturally present in water as a result of the biological decay of plant and animal matter. Higher concentrations in surface waters can indicate contamination from waste treatment facilities, raw sewage, industrial effluents (particularly from petroleum refineries),...

  • Spectroquant® Chromate Test (chromium VI) Method: photometric

    UN Number: UN3316

  • Iron (Total & Soluble) VACUettes Kit, Range: 0-120 & 120-1200 ppm

    Iron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron...

  • Formaldehyde CHEMets Kit

    Formaldehyde, a toxic substance, is used in the following applications: metal plating baths, textile treatments, biological specimen preservatives, and disinfectants of medical equipment. Commercial formaldehyde gas is readily soluble in water. The Purpald Method Reference: Purpald® developed by...