Select up to 3 products
Novel low pressure/vacuum tube for NMR and EPR spectroscopy. A 4X larger sealing surface eliminates leaks and greatly increases its lifetime when compared to traditional gas-tight tubes. Offers a convenient flame-free sealing solution for air sensitive or volatile liquid samples at any pressure from...
These cuvettes have four optically clear sides.Note: polystyrene and polymethacrylate cuvettes are incompatible with some organic solvents. Synonyms: cuvette; plastic cuvette; plastic cuvettes Application: Fluorimeter cuvette may be used : •to perform a fluorimetric assay of the hepatic microsomal...
4.0mm ID Cup Inlet Liner for PerkinElmer Auto SYS and Clarus GCs, equipped with split/splitless inlets
Stainless Steel pitch blade for 10L bioreactor systems . Right hand upward. Specifications: Material: 316L Stainless Steel Size: 3 1/4"
316L Stainless Steel Sparger Assembly with Stainless Steel Frit for 7 Liter Bioreactor System. Specifications: English Threads Material: 316l SST With Electropolish Finish Ra 32 Or Better Tubing Specifications: .250" OD X .152" Id Overall Length: 10 43/64" Insertion Length: 9 1/4" With SST Frit10...
Enhance your chromatography applications with Restek's high-quality Replacement CarboFrit Inserts. Specifically designed for Gas Chromatography, these inserts offer superior separation and analysis of vaporizable compounds. Manufactured by Restek, a trusted leader in scientific supplies, these...
POLYGOSIL® Irregular silica phases for LC, CN (cyano, nitrile) modified Features Irregular silica for analytical application, pH stability 2–8 Available pore sizes 60, 100, 300 and 1000 Å Available particle sizes 5 µm, 7 µm and 10 µm
Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations. Choose SGE technology to improve your chromatography.
Ensure the integrity of your NMR spectroscopy samples with these 5 mm NMR tube caps. These caps are designed to provide a secure seal, limiting the risk of contamination or sample loss during the analysis process. They are compatible with 5 mm NMR tubes, which are commonly used in various scientific...
Fluorescent indicators for TLC UV indicators with efficient radiation for short-wave as well as long-wave UV ranges UV254: manganese activated zinc silicate with absorption maximum at 254 nm; green fluorescence; relatively susceptible towards acids; thus its fluorescence can be completely quenched...
Connect a guard column to an analytical column Repair a broken column Connect a column outlet to a transfer line
Caps not included (sold separately). Restek's Headspace Screw-Thread Vials are engineered for optimal performance in headspace gas chromatography applications. These vials offer a secure sealing solution, minimizing sample evaporation and contamination. Their precision manufacturing ensures...
These plastic caps will easily slip over the ends of packed GC columns to protect them during storage. Application: Plastic column cup maybe used to close the immunoaffinity chromatography column used for separating cross-linked protein complexes adhering to P1 protein of Mycoplasma pneumonia.
Reduces the release of hazardous materials from the capillary split vent into the lab Includes connecting lines and mounting kit
Manufactured by Restek, this 4.0mm ID Precision Inlet Liner is a high-quality component designed for use in gas chromatography systems. The liner is equipped with wool, enhancing the vaporization of samples and ensuring even distribution for optimized performance. Specifically designed for Agilent...
Precision Wilmad NMR tubes are suitable for high field NMR spectroscopy. NMR tube has an open-top, screw-thread cap with a PTFE/silicone septum that permits addition of reactants or samples via syringe through the cap. Also good for sample storage. Caps and septa are replaceable.Excellent for...
0.018-inch ID jets: Used for most general-purpose packed column applications 0.030-inch ID jets: For packings that exhibit high bleed and that frequently clog the tip of smaller 0.018-inch jets Standard Version Threads specially coated for easy installation and removal Special processing ensures the...
Reduces water to less than 10 ppb; indicator changes from yellowish-green to blue at 5% relative humidity Prepurged for fast stabilization Reduces noise from high-sensitivity detectors Heavy-walled glass body prevents oxygen and water infusion 10 µm frit prevents microparticulate damage to...
Replacement Viton O-Rings for use with the Agilent Flip Top Inlet Sealing System, 10-pk.
Graphite Ferrules Preconditioned to eliminate outgassing. High-purity, high-density graphite. Smoother surface and cleaner edges than conventional graphite ferrules. Contain no binders that can off-gas or adsorb analytes. Stable to 450°C. Vespel/Graphite Ferrules VG2, 60% Vespel/40% graphite...
Made of Pyrex® borosilicate glass for compatibility with ground joints, valves, and vacuum racks. Precision ground and highly polished for spinning stability and highest resolution. Tubes have round bottoms and include a sandblasted marking spot for labeling samples. Tubes are thin-walled. Tubes...
with PTFE lid Legal Information: Suprasil is a registered trademark of HERAEUS QUARZGLAS GMBH & CO.
Tubes have round bottoms and include a sandblasted marking spot for labeling samples. Tubes that are 9 in. L are for making standards and for use with tip-off manifolds. Economy and disposable Wilmad NMR tubes are best used for high-throughput NMR spectroscopy. (All economy tubes come with caps)...