Agilent Technologies ICP-OES

Agilent Technologies ICP-OES

Products (15082)

Compare Tool

Select up to 3 products

  • < Previous
  • > Next
  • Plgel Olexis GPC Column

    Agilent Technologies

    PLgel Olexis GPC columns are optimized for the analysis of high-molecular weight polymers and high-temperature GPC analysis. Olexis columns are the industry standard for analysis of polyolefin, polyethylene, polypropylene, and high-performance polymers. Even at elevated temperatures, the PL Olexis...

  • Holmium Perchlorate

    Agilent Technologies

    Holmium perchlorate, 4% in perchloric acid, sealed in quartz cuvette, wavelength accuracy standard. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • Fluorinated O-Ring

    Agilent Technologies

    A number of O-rings are used throughout the current Agilent Mark 7 flame atomization system, and the earlier Agilent Mark VI flame atomization system, including on nebulizer components, the spray chamber and the burner. Regular inspection of the O-rings is recommended, especially when completing...

  • Multi-mode Sample Introduction System

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Glass Barrel

    Agilent Technologies

    The Agilent Technologies 26 mL glass barrel with decal, is often used for smooth functioning of chromatography system models. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • N-Glycanase (700 ul) for GlykoPrepPlus

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Pursuit MetaGuard HPLC Guard Column

    The Agilent Pursuit family of HPLC columns offers reliable performance in various common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11. Pursuit columns are available in many dimensions, including preparative HPLC columns. In addition, both traditional (Pursuit) and high...

  • Plunger Housing

    Agilent Technologies

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Atomic Absorption Calibration Standard

    The Agilent Technologies strontium 500 mL atomic absorption calibration standard with concentration levels of 1000 ug/mL is a single element standard that helps in ensuring the stability and performance of atomic absorption analyses. This product is only available to U.S. Domestic Customers. For...

  • Intuvo Gas Chromatography Column Module

    Agilent J&W Premium Polysiloxane Intuvo GC columns (compatible only with the Intuvo 9000 GC System) are most common stationary phases. Polysiloxanes are stable, robust, and versatile, and are available in the greatest variety. Standard polysiloxanes are characterized by the repeating siloxane...

  • EaseAlign Vessel

    Agilent Technologies

    Dissolution vessels are used to hold dissolution media during drug release. Agilent provides a variety of dissolution vessels for use with Agilent dissolution apparatus. Selected verified vessels are available containing a Certificate of Conformance (COC). TruCenter and EaseAlign vessels are...

  • Pursuit Reversed Phase HPLC Column

    The Agilent Pursuit family of HPLC columns offers reliable performance in various common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11. Pursuit columns are available in many dimensions, including preparative HPLC columns. In addition, both traditional (Pursuit) and high...

  • Zorbax Reversed-Phase Liquid Chromatography Column

    The ZORBAX column family is one of the most popular high-performance liquid chromatography (HPLC) column families for reversed-phase HPLC. ZORBAX columns are based on traditional fully porous particles and offer the highest loading capacity and resolution. From Eclipse Plus, Eclipse XDB, StableBond,...

  • Chrysene-d12 Standard 2000 ug/mL dichloromethane 1X1ML

    Analyte: Chrysene-d12, CAS Number: 1719-03-5; InChl: WDECIBYCCFPHNR-AQZSQYOVSA-N . EPA, Method: 680.

  • Simetryn Standard 100 ug/mL acetone 1X1ML

    Analyte: Simetryn, CAS Number: 1014-70-6.

  • Atomic Absorption Calibration Standard

    Agilent aqueous single element standards for AA are certified by high performance ICP-OES (HP-ICP-OES), a technique developed by the National Institute of Standards and Technology (NIST). NIST uses HP-ICP-OES to certify their SRM 3100 series of spectrometric single element solution standards. NIST...

  • Agilent Solid Phase Microextraction Fiber/Arrow Manual Injection Kit

    Agilent offers SPME fibers in a range of chemistries, formats, and for use with autosamplers or manual injections. SPME fibers can be used multiple times as long as they are treated with the proper care and caution. Each fiber has a color-coded or notched hub, indicating the type of coating on the...

  • Tert-Butylbenzene Standard

    Agilent Technologies

    Tert-butylbenzene Standard

  • Internal Standard 2000 ug/mL methanol 1X1ML

    Analyte: 4-Bromofluorobenzene, CAS Number: 460-00-4; Analyte: a,a,a-Trifluorotoluene, CAS Number: 98-08-8 . EPA, Method: 8020A.

  • Base/Neutrals Surogate Standard 1000 ug/mL acetone/methylene chloride 1X1ML

    Analyte: Nitrobenzene-d5, CAS Number: 4165-60-0; Analyte: p-Terphenyl-d14, CAS Number: 1718-51-0; Analyte: 2-Fluorobiphenyl, CAS Number: 321-60-8 ; . EPA, Method: 625.

  • Sulfaquinoxaline Standard 1000 ug/mL acetone 1X1ML

    Analyte: Sulfaquinoxaline, CAS Number: 59-40-5.

  • Metasil Conventional HPLC Column

    Metasil® HPLC column - excellent peak shape for basic analytes. Exceptionally high surface coverage. Improved polar compound retention. Enhanced selectivity. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • EN 14105:2003 Standard #3 various concentrations pyridine 1X1ML

    Analyte: Glycerol, CAS Number: 56-81-5; Analyte: 1-Oleoyl-rac-glycerol, CAS Number: 111-03-5; Analyte: 1,3-Diolein, CAS Number: 2465-32-9; Analyte: Triolein, CAS Number: 122-32-7; Analyte: S-(-)-1,2,4-Butanetriol, CAS Number: 42890-76-6; Analyte: Tricaprin, CAS Number: 621-71-6 . EU, Method: EN...

  • Quick-Connect Heat Exchanger Large ID HF

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • < Previous
  • > Next

Compare Tool

Select up to 3 products