Teknipure's TekniPolyPro™ Presat, meltblown polypropylene cleanroom wipers, presaturated with 0.2 filtered 70% IPA and 30% DI water, are engineered for precision cleaning in controlled environments. These low-lint wipes are ideal for removing contaminants, residues, and particles from surfaces in cleanrooms, pharmaceutical manufacturing, semiconductor fabrication, biotech labs, and medical device production.
These cleanroom alcohol wipes are manufactured in an ISO-certified facility in USA and are lot traceable, ensuring they meet stringent GMP, USP <797>, and USP <800> requirements. Designed for use in ISO 5–8 environments, these pre-wetted cleanroom wipes help maintain compliance and reduce the risk of cross-contamination.
Packaging: 50 Ea/Flex Pack, 24 Packs/Case, Total 1200 wipes/case
https://www.thomassci.com/Teknipure-Sample-Request
Purity Specifications
| Particles & Fibers | Upper Limit (x 10^6 particles/m^2) |
| Particles >0.50um | <20.0 |
| Particles >5.0um | <3.0 |
| Fibers >100um | <1000 |
*Particles: IEST-RP-CC004.3 Section 6.1.4
Fibers: IEST-RP-CC004.3 Section 6.2.2 (Orbital Shake Test)
-
Nonvolatile Residue
| Extractant | Target |
| IPA | <0.005 g/m^2 |
| DI Water | <0.010 g/m^2 |
*IEST-RP-CC004.3 Section 7.1.2 (Short Term Extraction)
-
Extractable Ions
| Ion | Upper Limit |
| Sodium (Na^+) | <0.50 ppm |
| Potassium(K^+) | <0.50 ppm |
| Calcium (Ca^2+) | <1.0 ppm |
| Chloride (Cl^-) | <1.0 ppm |
| Magnesium (Mg^2+) | <1.0 ppm |
* IEST-RP-CC004.3 Section 7.2.2.1B (Standard Extraction)
-
Physical Properties
| Basis Weight | 35 g/m^2 |
| Thickness | 0.20mm (+/- 2mm) |
| Material | 100% Polypropylene |