PerkinElmer Lab Supplies

PerkinElmer Lab Supplies

Products (591)

Compare Tool

Select up to 3 products

  • Uranium 1 µg/mL Single Element Pure Standard

    Each standard is supplied with a comprehensive Certificate of Analysis that documents its quality and reliability. Each standard: Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

  • Chromium (Cr) Lumina Hollow Cathode Lamp

    Single Element Lumina hollow cathode lamp (HCL) for the detection of elemental Chromium (Cr). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and...

  • Mercury (Hg) Lumina Hollow Cathode Lamp

    Single Element Lumina hollow cathode lamp (HCL) for the detection of elemental Mercury (Hg). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and...

  • 200 uL/min self-asp capillary

    200 µL/min self-aspirating sample capillary for ST nebulizer. 0.30 mm i.d., yellow marker

  • 1-Slot Quartz Outer Tube for Optima 8x00 D-Torch

    The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.

  • Platinum Hangdown Wire Kit

    Includes six preformed wires. PerkinElmer's Platinum Hangdown Wire Kit is specifically designed for use in gas chromatography applications. Composed of high-purity platinum, the wires ensure accurate and reliable results in analytical procedures. This kit provides the necessary components to enhance...

  • Palladium (Pd) Lumina Hollow Cathode Lamp

    Single Element Lumina hollow cathode lamp (HCL) for the detection of elemental Palladium (Pd). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and...

  • 7mL Polypropylene Round Reagent Containers for PerkinElmer AS-800 Graphite Furnace Autosampler

    For blank solutions, reagent solutions or matrix modifiers. Meet the demands of your laboratory work with the high-quality 7mL Polypropylene Round Reagent Containers from PerkinElmer. Engineered for use with the AS-800 Graphite Furnace Autosampler, these containers offer precise, repeatable results...

  • Argon/Nitrogen Regulator

    Can be used with Argonor Nitrogen and hasa CGA 580 fitting. Acolor-coded hose with1/4-inch SWAGELOKfittings is also included. Max Inlet Pressure:3000 psig

  • Zinc (Zn) Pure Single-Element Standard, UN3264

    Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities...

  • Replacement Acetylene Filter Cartridge

    Ensure optimal performance of your gas chromatography systems with PerkinElmer's Replacement Acetylene Filter Cartridge. Designed for efficiency and reliability, this product is an essential part of maintaining the purity of acetylene gas used in your critical experiments. This replaceable cartridge...

  • Deuterium Lamp for LAMBDA 365

    Provide the best wavelength coverage across the working range of the spectrometer for consistently high performance.

  • Nickel (Ni) Pure Single-Element Standard, 1,000 µg/mL, 2% HNO3

    Each PerkinElmer Nickel (Ni) Pure Grade Atomic Spectroscopy Calibration Standard is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability. Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 500 mL

  • Rechargeable Desiccant Kit

    Rechargeable Desiccant Kit comes with four desiccant cartridges. Rechargeable desiccant cartridges are contained in rigid metal cages which are user-installable. Two cartridges are required for Spectrum 65/100/100NTS/400 and Frontier spectrometers. It is recommended to have spare desiccant...

  • PTFE Capillary Tubing

    PFA sample capillary 0. 062 o. d. x 0. 020 i. d. in (1. 59mm x 0. 5mm)60cm length. For use with P/N WE024372 connector.

  • Tray-Spill Metal

    PerkinElmer

    The Tray-Spill Metal by PerkinElmer is crafted to provide effective spill containment in laboratory settings. This tray is designed to capture and contain liquid spills, preventing contamination and maintaining a safe work environment. Constructed from durable metal, it offers resistance to...

  • GemCone High Dissolved Solids Nebulizer

    High solids Gem Cones are for samples with high dissolved solids (up to 20%). This cone spray nebulizer allows you to analyze samples with higher solids concentration than is possible with a Cross-Flow nebulizer. Gem Cone nebulizers require an end cap for use with Ryton Scott Spray Chambers. High...

  • Stainless Steel Pans, Covers and O-Rings

    Pans contain the sample in a sealed environment throughout an experiment. The sealing suppresses the vaporization of a solvent or contains a volatile reaction product, thereby eliminating the interfering effects of the heat of vaporization.

  • 1 mL/min self-asp capillary for ST Nebulizers

    1 mL/min self-aspirating sample capillary for ST nebulizer 1 mm i.d., gray marker

  • Potassium (K) Pure Single-Element Standard, 1,000 µg/mL, 2% HNO3, 125 mL

    Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

  • 200µL Sample Loops

    Tubing Adapters and Connectors provide a means to connect the component shown to the screw fittings of the PTFE tubing assemblies or to connect the tubing components described.

  • Magazine for Peristaltic Pump, Two narrow

    Two narrow (>2mm) tubing channel.

  • KBr Window Assembly

    User replaceable parylene-coated potassum bromide sample compartment windows compatible with Spectrum One/100 and Frontier Optica.

  • Selenium (Se) Pure Single-Element Standard, 1,000 µg/mL, 2% HNO3, 125 mL

    Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 125 mL Features and Benefits Pure Grade Standards for AA and ICP-OES Analyzed by ICP-OES Analyzed by Classical Wet Assay 32 trace impurities analyzed by ICP-MS of the final solution and reported on the certificate Impurities reported at...

Compare Tool

Select up to 3 products