Agilent Technologies Lab Supplies

Agilent Technologies Lab Supplies offer reliable and precise solutions for labs, essential for researchers and professionals aiming for accurate results. This category includes a wide range of Agilent Technologies products, from consumables to advanced equipment, designed to meet the highest quality and performance standards.

Key features of Agilent Technologies lab supplies include cutting-edge technology, robust construction, and user-friendly designs. These products ensure dependable operation, minimizing downtime and maximizing productivity. For example, Agilent Technologies consumables, such as columns and sample vials, are crafted for optimal compatibility with Agilent instruments, ensuring seamless integration and superior performance. Agilent also offers a variety of percise and dependable chromatography reagents.

The practical benefits of using Agilent Technologies equipment are clear: consistent results, improved efficiency, and reduced maintenance costs. Available in various options, sizes, and configurations, these lab supplies cater to diverse applications, from chromatography to spectroscopy.

Whether you require precision or durability, Agilent Technologies lab supplies provide the quality and reliability your work demands.

Agilent Technologies Lab Supplies

Products (15139)

Compare Tool

Select up to 3 products

  • > Next
  • Autosampler Syringes

    Agilent Technologies

    Needle Styles Broad selection of syringes for manual and auto injection to provide accurate and effective sampling Tapered or straight needles Fixed Needle Syringe The epoxy-cemented, stainless steel needle is centered in the syringe barrel at the depth of the zero graduation mark. Do not heat above...

  • 2 ml Vial Caps/Septa

    Agilent Technologies

    Agilent 2 mL crimp top vials are crimp vials constructed from type 1 borosilicate glass. The unique low metal content nature of the high-quality material can help to protect your sample from destabilizing or leaching. Our associated crimp vial caps come with a choice of either PTFE/silicone, PTFE...

  • 2 ml Vial Caps/Septa

    Agilent Technologies

    Agilent 2 mL crimp top vials are crimp vials constructed from type 1 borosilicate glass. The unique low metal content nature of the high-quality material can help to protect your sample from destabilizing or leaching. Our associated crimp vial caps come with a choice of either PTFE/silicone, PTFE...

  • ZORBAX PrepHT and Agilent Prep Preparative Cartridge and Guard Column Hardware

    The ZORBAX PrepHT and Agilent Prep Preparative Cartridge and Guard column hardware kits have been developed to provide a convenient preparative 21.2 mm ID cartridge design. The 21.2 mm ID preparative cartridge columns are reusable and allow rapid change of column lengths from 50-250 mm for...

  • VOC Standard 2000 ug/mL methanol 1X1ML

    Analyte: Benzene, CAS Number: 71-43-2; InChl: UHOVQNZJYSORNB-UHFFFAOYSA-N; Analyte: Bromobenzene, CAS Number: 108-86-1; Analyte: Bromochloromethane, CAS Number: 74-97-5; Analyte: Bromodichloromethane, CAS Number: 75-27-4; InChl: FMWLUWPQPKEARP-UHFFFAOYSA-N ; Analyte: Bromoform, CAS Number: 75-25-2;...

  • Purgeable Gas Standard 2000 ug/mL methanol 1X1ML

    Analyte: Chloroethane, CAS Number: 75-00-3; InChl: HRYZWHHZPQKTII-UHFFFAOYSA-N; Analyte: Chloromethane, CAS Number: 74-87-3; InChl: NEHMKBQYUWJMIP-UHFFFAOYSA-N ; Analyte: Bromomethane, CAS Number: 74-83-9; InChl: GZUXJHMPEANEGY-UHFFFAOYSA-N; Analyte: Vinyl chloride, CAS Number: 75-01-4; InChl:...

  • Rotor Seal

    Agilent Technologies

    Rotor Seals used for Manual and Automatic Liquid Samplers used in HPLC and their Material Properties. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • Bond Elut Solid Phase Extraction Cartridge

    Alumina, like silica, is an extremely polar sorbent. The alumina surface tends to be slightly more stable under high pH conditions than unfunctionalized silica. The small particle size of the Bond Elut Alumina range ensures high extraction efficiency, even when small bed masses are used. This...

  • Isooctane Solvent Blank 100% (v/v) isooctane (2,2,4-trimethylpentane) 1X2ML

    Analyte: 2,2,4-Trimethylpentane, CAS Number: 540-84-1.

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut Certify II is designed for the rapid and effective extraction of acidic drugs and metabolites from urine and other biological matrices for forensic use. Certify II is a mixed mode cartridge with nonpolar C8 and strong anion exchange (SAX) functionalities. It has been optimized for acidic...

  • Torch Injector

    Agilent Technologies

    Agilent ICP-OES inert torches with alumina/ceramic injectors allow the analysis of samples containg hydrofluoric (HF) acid. HF resistant torches/injectors are suitable for handling HF digests unlike standard quartz injectors where the free HF attacks and degrades the quartz components. Inert torches...

  • CLP ICP Calibration Standard various concentrations water with dilute nitric acid 125ML

    Analyte: Arsenic (III) oxide (ICP grade) (as arsenic), CAS Number: 1327-53-3; Analyte: Selenium (IV) oxide (ICP grade) (as selenium), CAS Number: 7446-08-4; Analyte: Cadmium nitrate hydrate (ICP grade) (as cadmium), CAS Number: 10022-68-1; Analyte: Thallium (I) nitrate (ICP grade) (as thallium), CAS...

  • Dibromofluoromethane Standard 2000 ug/mL methanol 1X1ML

    Analyte: Dibromofluoromethane, CAS Number: 1868-53-7. EPA, Method: Individual Analyte.

  • Phenols Standard 20 ug/mL methanol 1X1ML

    Analyte: 4-Chloro-3-methylphenol, CAS Number: 59-50-7; Analyte: 2-Chlorophenol, CAS Number: 95-57-8; Analyte: 2-Methyl-4,6-dinitrophenol, CAS Number: 534-52-1; Analyte: 2,4-Dimethylphenol, CAS Number: 105-67-9; Analyte: 2,4-Dinitrophenol, CAS Number: 51-28-5; Analyte: 2,4-Dichlorophenol, CAS Number:...

  • Liner O-ring

    Agilent Technologies

    Liner O-rings are used to form a proper seal around the outside of the inlet liner between the inlet weldment and the turn-top. O-rings are composed of either graphite or fluorocarbon material, Graphite O-rings are used when operating inlet temperatures exceed 350°C. Agilent fluoroelastomer or...

  • Bifenthrin Standard 1000 ug/mL acetone 1X1ML

    Analyte: Bifenthrin, CAS Number: 82657-04-3.

  • Agilent EaseAlign Evaporation Cover

    A variety of evaporation covers are available to fit your apparatus and vessels. Evaporation plugs are used to minimize evaporation by sealing unused ports in the evaporation covers. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic...

  • Salt Standard 10.0 wt%   1L

    Agilent Technologies

    Salt Standard 10.0 wt pct

  • UltiMetal Plus Ferrule Set

    Agilent Technologies

    The Agilent 1/4 Inch UltiMetal Plus ferrule set is compatible GC systems with Low thermal mass column module. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • Tray for 4 Well Plates,adjustable,cooled

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Gas Chromatography Column Module

    Agilent J&W VF-WAXms is a high-performance polyethylene glycol column designed for GC/MS applications in the food, flavor, and fragrance markets, and especially where trace analyses are required. These applications often require higher temperatures to analyze polar compounds, and therefore need an...

  • InfinityLab Standard Capillary

    Agilent Technologies

    HPLC capillaries are used in the high-pressure part flow path to make connections between different modules and column. All Agilent HPLC capillaries are engineered and manufactured to provide the best fit to Agilent instruments and columns to protect the integrity of your results at every step of...

  • Agilent Vac Elut SPS 24 Manifold with Collection Rack

    The Vac Elut SPS 24 manifold allows you to process up to 24 SPE cartridges simultaneously. Like all Vac Elut manifolds, the SPS 24 is made from durable, solvent-resistant materials and engineered to last. The glass sides allow easy viewing of the entire sample collection process. This product is...

  • EASEALIGN LOCATING PINS (12)

    Agilent Technologies

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • > Next

Compare Tool

Select up to 3 products