Agilent Technologies Lab Supplies

Agilent Technologies Lab Supplies

Products (15139)

Compare Tool

Select up to 3 products

  • < Previous
  • > Next
  • Pursuit Reverse-Phased HPLC Column

    The Agilent Pursuit family of HPLC columns offers reliable performance in various common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11. Pursuit columns are available in many dimensions, including preparative HPLC columns. In addition, both traditional (Pursuit) and high...

  • Target Analytes Standard 200 ug/mL methanol 1X1ML

    Analyte: Benzene, CAS Number: 71-43-2; InChl: UHOVQNZJYSORNB-UHFFFAOYSA-N; Analyte: Carbon tetrachloride, CAS Number: 56-23-5; InChl: VZGDMQKNWNREIO-UHFFFAOYSA-N ; Analyte: tert-Butylmethyl ether, CAS Number: 1634-04-4; Analyte: Chlorobenzene, CAS Number: 108-90-7; InChl: MVPPADPHJFYWMZ-UHFFFAOYSA-N...

  • Captiva Syringe Filter

    Agilent Technologies

    Captiva syringe filters offer the industry's highest flow rates and loading capacities. Using Captiva syringe filters also significantly extends column lifetime. Choose from a variety of membrane types and pore sizes to prepare small-volume samples for High-Performance Liquid Chromatography (HPLC)...

  • FID Igniter Cable

    Agilent Technologies

    The Agilent Technologies FID igniter cable is suitable for use with flame ionization detector. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Hollow Cathode Lamp

    Agilent Technologies

    Agilent single element lamps for PerkinElmer AA instruments are designed and built to be equivalent to genuine PerkinElmer Lumina lamps. They are manufactured from the purest cathode materials for improved productivity, economical operation, and superb performance. Agilent lamps for PerkinElmer AA...

  • CTC Autosampler Syringe

    Agilent Technologies

    For precise, effective, sample delivery from your CTC autosampler, Agilent has the right syringe for you. Whether you're performing liquid or headspace injections, or using a CombiPAL or PAL3 autosampler, you'll find what you need among our wide range of syringes for CTC autosamplers. For help...

  • PAH Standard various concentrations acetonitrile 1X1ML

    Analyte: Naphthalene, CAS Number: 91-20-3; Analyte: Pyrene, CAS Number: 129-00-0; Analyte: Fluorene, CAS Number: 86-73-7; Analyte: Anthracene, CAS Number: 120-12-7; Analyte: Phenanthrene, CAS Number: 85-01-8; Analyte: Fluoranthene, CAS Number: 206-44-0; Analyte: Acenaphthene, CAS Number: 83-32-9;...

  • VOC Standard 2000 ug/mL methanol 1X1ML

    Analyte: Chloroethane, CAS Number: 75-00-3; InChl: HRYZWHHZPQKTII-UHFFFAOYSA-N; Analyte: Chloromethane, CAS Number: 74-87-3; InChl: NEHMKBQYUWJMIP-UHFFFAOYSA-N ; Analyte: Bromomethane, CAS Number: 74-83-9; InChl: GZUXJHMPEANEGY-UHFFFAOYSA-N; Analyte: Dichlorodifluoromethane, CAS Number: 75-71-8;...

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W DB-35ms, a close equivalent to USP phase G42, is precision engineered to deliver excellent performance in a range of GC/MS applications, particularly in confirmation analysis. These bonded, crosslinked, mid-polarity columns operate over an extended temperature range up to 340/360 °C....

  • GC Capillary Column

    Agilent Technologies

    Gas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,...

  • ZORBAX RRHT Column

    Agilent Technologies

    eXtra Dense Bonding (XDB) is key to the exceptional performance of ZORBAX Eclipse XDB columns at intermediate pH. This dense bonding is accomplished by adding an extra-dense monolayer of C18, C8, phenyl, or CN-silane to the ultra-pure, fully-hydroxylated, ZORBAX Rx-silica surface. The packing is...

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • OneNeb V2 Nebulizer

    Agilent Technologies

    The Agilent Technologies OneNeb V2 nebulizer is the perfect replacement for glass concentric nebulizer and provides great resistance to organics and strong acids. Application: For PerkinElmer ICP-OES This product is only available to U.S. Domestic Customers. For research use only, not to be used in...

  • GC Ultra Inert Column

    Agilent Technologies

    Agilent J&W DB-5ms Ultra Inert columns deliver industry-leading analytical performance in a range of chromatographic applications. DB-5ms Ultra Inert is low bleed and features excellent signal-to-noise ratio and symmetric peak shapes, enabling high performance for challenging active analytes such as...

  • QuEChERS Extract Tubes, EN Method w/CH

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • AdvanceBio IPC a(2,3) Sialylated Triantennary N-Glycan Library

    InstantPC (formerly ProZyme) labeled glycan standards and libraries are commonly used as qualitative standards for LC/FLD and LC/MS. These standards come pre-labeled with InstantPC, ready to reconstitute and inject. Better detection of low abundance N-glycans in your LC/FLD or LC/MS method translate...

  • Standard Capillary

    Agilent Technologies

    HPLC capillaries are used in the high-pressure part flow path to make connections between different modules and column. All Agilent HPLC capillaries are engineered and manufactured to provide the best fit to Agilent instruments and columns to protect the integrity of your results at every step of...

  • Bond Elut Solid Phase Extraction Cartridge

    Florisil is a magnesia-loaded silica gel. Like silica, it is extremely polar in nature and ideal for the isolation of polar compounds from nonpolar matrices. The larger particle size of the sorbent enables fast flow for large sample volumes, and is therefore an attractive alternative to silica if...

  • Pursuit Reversed-Phase LC Column Cartridge

    The Agilent Pursuit family of HPLC columns offers reliable performance in various common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11. Pursuit columns are available in many dimensions, including preparative HPLC columns. In addition, both traditional (Pursuit) and high...

  • cis-1,2-Dichloroethene Standard 5000 ug/mL methanol 1X1ML

    Analyte: cis-1,2-Dichloroethene, CAS Number: 156-59-2; InChl: KFUSEUYYWQURPO-UPHRSURJSA-N. EPA, Method: Individual Analyte.

  • Corrosion Resistant Sampling Probe

    The Agilent Technologies 0.6 mm sampling probe is made from epoxy polymer for durability and the PTFE lining on the surface provides good corrosion resistance. Application: For AS-90/90A/90 Plus/91/93 Plus Autosamplers. Suitable for InOrganic Acids & Most Organic Solvents, Except NMP This product is...

  • Agilent HC-C18(2), 4.6x250mm, 5um

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Chlorbufam Standard 100 ug/mL methanol 1X1ML

    Analyte: Chlorbufam, CAS Number: 1967-16-4.

  • < Previous
  • > Next

Compare Tool

Select up to 3 products