Extraction

Compare Tool

Select up to 3 products

All Products

Extraction

1 - 32 of 61
Sort
View
Show
  • High Performance Cellulose Extraction Thimbles

    GE Healthcare

    Cellulose extraction thimbles produced from high-quality alpha cellulose cotton linter with excellent mechanical strength and retention. Standard single thickness thimbles have a wall thickness of approximately 1-1.5mm. Double thickness thimbles have a wall thickness of approximately 2mm for…

  • KIMAX SOXHLET TYPE EXTRACTORS

    Kimble

    With Standard Taper Joints Complete with Allihn condenser with joint at bottom, Soxhlet extraction tube with top and bottom joint and flat-bottom flask Available in small, medium and large capacities Small Extractor with 125 mL flask (4406E10, E16, E22) Extraction chamber 30 mm i.d. x 95…

  • Norton Alundum Extraction Thimbles

    Saint Gobain

    For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

  • Base assembly, for 96-well plate manifold

    Agilent Technologies

    The base accomodates lids that hold either a user-defined selection of flexible cartridges, or fixed format 96-well plates with each well loaded with the same sorbent.

  • Thomas Cellulose Extraction Thimbles

    Thomas®

    Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products,…

  • PYREX® Extractors With Standard Taper Joints

    Corning

    Condensers have water-jacketed Standard Taper inner joint. Complete with condenser, flask and extraction tube. The low thermal expansion rate means that the PYREX brand extractors can be routinely used in applications requiring protracted heating at temperatures as high as 230°C. The inherent…

  • Extraction System

    Avantor - J.T.Baker®

    The BAKER SPE-12G is compatible with a large variety of glassware, including standard test tubes, volumetric flasks and autosampler vials. Samples are aspirated through disposable, prepacked extraction columns which selectively remove compounds from solution. Extracted compounds are then eluted…

  • Vaccuum Manifolds And Accessories

    Agilent Technologies

    Agilent manifolds and accessories complement the quality of AccuBOND II sorbents. Flexible configurations and availability as complete assemblies or individual components mean that the user has the necessary capability at any stage from method development to high throughput operation. Vacuum…

  • PYREX Accelerated One-Step Extractor/Concentrator

    Corning

    Modular PYREX Accelerated One-Step extractor-concentrator performs extraction, concentration, and drying with the same apparatus and is designed for use with solvents of heavier specific gravity than sample being extracted.  Extraction and concentration can be done in 1/3 of the time.…

  • PYREX® Graduated Funnel, 47 mm, for Assembly with Fritted Glass Support Base

    Corning

    These graduated funnels,are designed for assembly with the fritted glass support base. Cat. No. 33972-B.

  • Cellulose Extraction Thimbles

    Ahlstrom

    Ahlstrom‘s high purity cellulose extraction thimbles are most commonly used in Soxhlet extraction units for the separation of individual components from a mixture of solids and semisolids by solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic or…

  • PYREX® Fritted Glass Support Base, 47 mm, for Assembly of Graduated Funnel

    Corning

    This 47 mm fritted glass support base is designed for assembly with either the 300 mL graduated glass funnel, Cat. No. 33971-300 or 1000 mL graduated glass funnel, Cat. No. 33971-1L.

  • Sediment Extraction Apparatus

    Koehler

    Test Method Determines sediment content of crude oil and fuel oils by extraction with toluene. A test portion of the sample is placed in a refractory thimble. Toluene is gently boiled and its vapors condensed and allowed to drip into the sample funnel. The toluene washes out all of the…

  • Glass Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can…

  • Standard Cellulose Extraction Thimbles

    GE Healthcare

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • PYREX® Coarse Porosity Fritted Thimbles

    Corning

    These PYREX® coarse porosity fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. For PYREX® extractors and extraction apparatus, see Nos. 3740 through 3880.

  • Mini Closed Loop Extractors

    Best Value Vacs

    1.5" x 18" 304 Stainless Steel Material Tube 90-135g 304 Stainless Steel Heavy Duty Miniature Ball Valves System Rated to 100PSI Multiple port connections for _" 316 Stainless SAE 37 Degree 304 Stainless Steel Base Container 4" diameter by 8" tall Tri-Clamps…

  • PYREX Soxhlet Extractors

    Corning

    Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

  • Cellulose Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Cellulose Fiber is made from alpha cotton cellulose. These thimbles are binder-free and suitable for Soxlet…

  • Glass Microfiber Extraction Thimbles

    Thomas®

    Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Glass Microfiber Thimble material applications include gravimetric methods for hot environments, gravimetric methods for acidic gasses, and extraction…

  • Soxhlet Extraction Apparatus

    Wilmad LabGlass

    Used for the continuous extraction of solids with a suitable solvent. Units are supplied complete with flat bottom boiling flask, Soxhlet extractor and Allihn condenser. The extractor capacity shown is the solvent volume held in the extractor to the top of the siphon tube. The siphon tube is…

  • Extra Large Soxhlet Extraction Apparatus

    Wilmad LabGlass

    This borosilicate glass X-Large Soxhlet extraction apparatus is used for the continuous extraction of solids with a suitable solvent. Complete units are supplied with a round bottom boiling flask (LG-7220-184 or LG-7220-188), a Soxhlet extraction tube (70mm or 100mm approx. I.D.) and an Allihn…

  • High-Purity Glass Extraction Thimbles

    GE Healthcare

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • Baker Spe-24G Glass Manifold 1 Pk

    Avantor - J.T.Baker®

    BAKER SPE-24G with 24 ports for simultaneously processing 24 SPE columns. Includes 24-port vacuum manifold, sample collection rack, height adjustable shelves, vacuum gauge/controller.  HTS Number: 8421290065 Specific Gravity: 1L = 0.00 Kg Management of Change: N

  • Disposable Liners for Visiprep DL Manifolds

    MilliporeSigma

    Material: PTFE Packaging: Pack of 100

  • Quartz Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Silica Fiber (Quartz) thimbles are made of pure quartz microfibers and are binder-free. Ideal for air…

  • Modified Soxhlet Extraction Apparatus

    Wilmad LabGlass

    These large capacity Soxhlet extraction apparatus with modified design feature a wide mouth opening that provides easier charging and sample removal and a large area at the filter plate for rapid drainage of the solvent. Bulky solids may be placed directly on a fiberglass mat (not supplied) and…

  • Micro Soxhlet Extraction Apparatus

    Wheaton

    Used for continuous extraction of analytes from a solid into an organic solvent WHEATON Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the…

  • Goldfisch Fat Extractor Accessories & Replacement Parts

    Labconco

    Goldfisch Fat Extractor Accessories and Replacement Parts include glassware, gaskets and other components.

  • PYREX® 45mm Diameter Coarse Porosity Fritted Thimble, 130mm Long

    Corning

    These 45mm diameter PYREX® coarse porosity (40 to 60µm) fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. These medium length thimbles are 130mm long. For PYREX®…

  • PTFE Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…

  • Fat Extraction Flask, AOAC

    Wilmad LabGlass

    These borosilicate glass extraction apparatus are used to measure the fat content in dairy and other food products. Reference AOAC 989.05 for fat in milk. Top is tooled to accept rubber stoppers (not included).

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.