Thin Layer Chromatography (TLC) Plates
-
Cellulose plates (TLC and HPTLC)
MilliporeSigmaFor analysis of polar substances The organic sorbent cellulose is particularly suitable for the separation of hydrophilic substances by partition chromatography. EMD Millipore cellulose plates include classical TLC grade or HPTLC plates for demanding high-performance separations: TLC…
-
Silica Gel GF UNIPLATES
Miles Scientific (Analtech)Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulfuric acid charring visualization. These plates are commonly scraped from the glass backing to isolate separated components for…
-
Nano-SIL NH2 Amino-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g particle size 2–10 μm pH stability 2–8 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV (254…
-
Features Silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm; standard grade Outstanding wettability for precise colorization results, even with 100 % aqueous detection reagents Excellent separation…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
TLC Silica gel 60 F254
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
TLC Developing Tank
DWK Life Sciences (Kimble)Constructed of sturdy molded glass bricks Withstands regular use for many years The tank’s clear sides allow for visual inspection of TLC plates up to 20 x 20 cm size. The top of the tank is ground flat to match the lids and the edges are beveled to remove any sharp edges. The bottoms are…
-
HPTLC silica gel 60
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
PLC SILICA GEL 60, 0.5 MM 20 GLASS PLATES 20 X 20 CM
MilliporeSigmaPLC plates allow users to separate samples that vary greatly in size – from grams down to milligrams. Available with or without a fluorescence indicator, PLC plates has 0.5 mm thickness. They also use the same proven EMD Millipore silica-binder technology as in analytical TLC plates. To…
-
HPTLC SILICA GEL 60 RP-18 W 25 GLASS PALTES 10 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
10 cm Latch-Lid Chromatotank
General Glass BlowingRequires less solvent to maintain equilibrium Gives excellent retention of solvent saturated chamber Holds two 10 x 10 cm plates The smaller cubic inch chamber allows for a faster and more uniform solvent-saturated atmosphere. Single molded tank has a flat ground top, beveled for…
-
Labels applied to all 4 sides of the plate. No sequence number duplicates. Exceptional print quality and resolution. Resistant to commonly used laboratory reagents. Resistant to temperature ranges of -80ºC to +52ºC. See Product Details below for bar code label specifications. Microplate…
-
TLC SILICA GEL 60 W F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
CHIRALPLATE Special Layer for TLC Enantiomer Separation
MACHEREY-NAGELFeatures Reversed phase nano silica impregnated with Cu(II) ions and a chiral selector (a proline derivative, DP 31 43 726 and EP 0 143 147) Separation based on ligand exchange, i. e. formation of ternary mixed-ligand complexes with the Cu(II) ions differences in the stability of the…
-
HPTLC Silica Gel 60
MilliporeSigmaThese plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
HPTLC Silica gel F254 GLP
MilliporeSigmaFeatures individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore silica found in…
-
HPTLC SILICA GEL 60 RP-18 F254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
Features IONEX-25 SA-Na: mixture of silica and a strongly acidic cation exchanger coated to polyester sheets IONEX-25 SB-AC: mixture of silica and a strongly basic anion exchanger coated to polyester sheets Both layers contain an inert organic binder. Recommended application:…
-
Features Base material: silica 60, specific surface (BET) ~ 500 m 2 /g mean pore size 60 Å specific pore volume 0.75 mL/g particle size 5–17 μm pH stability 2–10 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV…
-
TLC Silica gel 60
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
RP-18 W/UV254 Octadecyl-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g particle size 2–10 μm for preparative plates (1 mm thickness of layer) standard silica 60 particle size 5–17 µm pH stability…
-
Mixed Layers for TLC
MACHEREY-NAGELFeatures Alox/CEL-AC-Mix-25 : mixed layer of aluminium oxide G and acetylated cellulose recommended for separation of PAHs SILCEL-Mix-25 : mixed layer of cellulose and silica, recommended for separation of preservatives and other antimicrobial compounds
-
HPTLC SILICA GEL 60 NH2F254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaOur NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative…
-
SIL G Unmodified Standard Silica Layers for TLC
MACHEREY-NAGELSilica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm; standard grade Thickness of layer for analytical plates 0.25 mm, for preparative plates 0.5 and 1 mm For 2 mm preparative layers a slightly coarser…
-
TLC SILICA GEL 60 W 25 ALUMINIUM SHEETS 20 X 20 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
TLC SILICA GEL 60 50 ALUMINIUM SHEETS 5 X 10 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
TLC Silica gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
TLC Silica Gel 60 RP-18 F254s
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
TLC SILICA GEL 60 F254 50 ALUMINIUM SHEETS 5 X 10 CM
MilliporeSigmaEMD Millipore classical silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…