Reversed Phase Tlc Plates

Compare Tool

Select up to 3 products

Reversed Phase Tlc Plates
1 - 18 of 18
Sort
View
Show
  • RP-18 W/UV254 Octadecyl-Modified HPTLC Silica Layers

    MACHEREY-NAGEL

    …carbon content 7.5 % Order of polarity: silica > DIOL > NH2 > CN > RP-2 > C18-50 > RP-18 W > C18-100 Normal phase or reversed phase separation modes with eluents from anhydrous solvents to mixtures with high concentrations of water (see figure); the relative polarity of…

  • Reversed Phase Octadecyl Silanized Silica Gel UNIPLATES

    Miles Scientific (Analtech)

    These reversed phase TLC plates have been manufactured to be greater than 50% and less than 100% silanized. Because of this they are hydrophobic, but wettable. Features: 14% carbon content Acid stable (UV254) fluorescent indicator Glass backing 250um coating thickness 25…

  • Nano-SIL CN Cyano-Modified HPTLC Silica Layers

    MACHEREY-NAGEL

    …polarity: silica > DIOL > NH2 > CN > RP-2 > C18-50 > RP-18 W > C18-100 Available as glass plates or ALUGRAM® aluminium sheets Normal phase or reversed phase separation modes depending on the polarity of the developing solvent. Recommended application: steroid…

  • Nano-SIL C18 Octadecyl-Modified HPTLC Silica Layers

    MACHEREY-NAGEL

    …spots on a light-blue background. Order of polarity: Silica > DIOL > NH2 > CN > RP-2 > C18-50 > RP-18 W > C18-100 Reversed phase separation mode with eluents from anhydrous solvents to mixtures with high concentrations of water. Recommended application: alkaloids,…

  • HPTLC SILICA GEL 60 NH2 F254S 25 GLASS PLATES 20 X 10 CM

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion…

  • TLC Silice gel 60 NH2 F254s

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak…

  • CHIRALPLATE Special Layer for TLC Enantiomer Separation

    MACHEREY-NAGEL

    Features Reversed phase nano silica impregnated with Cu(II) ions and a chiral selector (a proline derivative, DP 31 43 726 and EP 0 143 147) Separation based on ligand exchange, i. e. formation of ternary mixed-ligand complexes with the Cu(II) ions differences in the stability of the…

  • HPTLC SILICA GEL 60 DIOL F254S 25 GLASS PLATES 10 X 10 CM

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion…

  • Acetylated Cellulose Layers for TLC

    MACHEREY-NAGEL

    Fibrous cellulose with 10 % content of acetylated cellulose available as POLYGRAM® polyester sheets Recommended application: reversed phase chromatography

  • Glass-Backed Analytical TLC Plates

    Miles Scientific (Analtech)

    This TLC plate can be developed using purely organic, organic/aqueous, and purely aqueous mobile phases. Due to this these plates have been used in numerous applications in normal phase chromatography as well as reversed phase chromatography. Common applications include the analysis of active plant…

  • HPTLC SILICA GEL 60 NH2 25 GLASS PLATES 20 X 10 CM

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion…

  • HPTLC SILICA GEL 60 CN F254S 25 GLASS PLATES 10 X 10 CM

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion…

  • HPTLC SILICA GEL 60 NH2F254S 25 GLASS PLATES 10 X 10 CM

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion…

  • DURASIL Unmodified Standard Silica Layers for TLC

    MACHEREY-NAGEL

    …~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 5–17 µm Hard, water-resistant and wettable layers due to a special binder system No reversed phase tendency, more polar than SIL G Available as glass plates with or without fluorescent indicator

  • RP-2/UV254 'Silanized Silica' Dimethyl-Modified Standard Silica Layers for TLC

    MACHEREY-NAGEL

    …carbon content 4 % Order of polarity: silica > DIOL > NH2 > CN > RP-2 > C18-50 > RP-18 W > C18-100 Normal phase or reversed phase separation modes with purely organic, organic – aqueous or purely aqueous eluents. Recommended application: active plant…

  • HPTLC-RP8F UNIPLATES

    Miles Scientific (Analtech)

    …availability of both normal phase and Reversed Phase HPTLC UNIPLATES completes HPTLC as a sensible, efficient and cost effective alternative technique for quantitative analysis. These Reversed Phase adsorbents share the features and benefits of silica gel HPTLC plates: high efficiency adsorbents,…

  • HPTLC Silica gel 60 DIOL F254s

    MilliporeSigma

    …conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion…

  • Nano-DURASIL Unmodified HPTLC Silica Layers

    MACHEREY-NAGEL

    …shorter migration distances, smaller samples and an increased detection sensitivity compared to DURASIL plates Different selectivity compared to ADAMANT and SIL-G plates no reversed phase tendency, more polar than Nano-SIL Available as glass plates with or without fluorescent indicator

Compare Tool

Select up to 3 products

Please Log In