Glass Tubing Connector

Compare Tool

Select up to 3 products

Glass Tubing Connector
1 - 32 of 123
Sort
View
Show
  • Glass 0.4 mL/min MicroMist Nebulizer for ELAN 5000/6x00/9000/DRCs/NexION 300/350…

    PerkinElmer

    …with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.25 mm I.D. x 700 mm long sample tubing. All MicroMist nebulizers glass are supplied with the EzyLok argon connector.

  • Tricorn Columns

    GE Healthcare

    …Packing Connector and the appropriate glass tube. Tricorn Packing Connector includes one packing connector and two EPDM O-rings. Packing connectors are available in three sizes for using different i.d. tubes: 5-5 is for 5-mm tubes on both sides; 5-10 is for a 5-mm tube on one side and a 10-mm tube

  • Y-Shaped Hose Connectors

    DWK Life Sciences (Kimble)

    Useful in connecting apparatus Glass Serrated tips hold tubing in place

  • Graduated Filtering Flasks with Quick-Release Hose Barb Connectors

    DWK Life Sciences (Kimble)

    …the connector provides greater flask stability, as tubing angled downward has less tendency to tilt the flask Flasks are designed for vacuum to 29” of mercury Made with a heavier wall than a standard Erlenmeyer flask Manufactured from 33 expansion, low extractable borosilicate glass

  • Connecting Tubes

    GSC International, Inc.

    …length 14mm arm length "Y" Shaped Glass Hose Connector. Available in the following sizes: 1/4" (6mm) arm length 5/16" (8 mm) arm length 3/8" (10mm) arm length 1/2" (12mm) arm length Straight Connecting Tube 8mm od x 63mm length

  • Safe-Lab® Joint Tubing Adapters

    Bel-Art Products

    …of glass tubing to be adjusted as required. An O-ring on the taper provides best sealing and the threaded polypropylene extracting nut ensures effortless removal. NOT autoclavable Safely and securely positions glass tubing in a 24/40 joint. Available for 8 and 10mm diameter glass tubing

  • Tube, Connecting

    Ace Glass

    Straight reducing connector tube, with ends of different size. Sold in packages of 6.

  • Condenser, Liebig, with Ace-Thred Connectors

    Ace Glass

    No Hold Up condenser with standard taper 24/40 inner and outer joint at bottom and top, #7 Ace-Thred inlet/outlet for connecting Ace-Safe hose connections with barb for 1/4" I.D. tubing. For replacement hose connections, see 5853. Complete item include

  • Connector, Ace-Safe, Tubing, PTFE

    Ace Glass

    Ace Safe threaded tubing connectors used to connect flexible tubing to #7,#11 or #15 Ace-Threds. Allows for easier connect-disconnect of tubing. A much safer design than glass hose barbs. All PTFE construction for lower extractables and higher temperature capability than the standard…

  • Adapter, Joint To Tube Compression, Right Angle

    Ace Glass

    Glass standard taper and spherical joint adapters featuring a right angle ground glass sidearm. The sidearm is used to make tube compression fitting connection to a wide variety of flexible and rigid tubing using our 12709,12711,12715 & 12716 product families of fittings.

  • Adapter, Nylon or PTFE, NPT, Tubing to Ace-Thred

    Ace Glass

    …and facilitates joining plastic or metal tubing to Ace-Thred glass fittings and adapters. This adapter is supplied with one FETFE o-ring (-176 does NOT come with o-ring). Adapter is available in nylon, HDPE (High Density Polyethylene), or PTFE. -120 and -125 are PTFE, MNPT to FNPT connectors.

  • Connectors, Threaded, Ace-Thred

    Ace Glass

    …threaded connectors, available in glass or 18-8 type 303 free machining stainless steel. For use in place of ground glass joints on flasks, columns, etc. Threads offer positive pressure O-Ring seal when used with fittings like 5837, 5838, 5840-5846, and 7506. Size mm refers to I.D. of tubing below…

  • Connectors, Tubing

    Ace Glass

    Small tubing connector comprised of a TFE, 1/4"-28 UNF 2B male nut and a Kel-F wedge insert. Designed for use with our 5838 Chromatography adapters, 1.5-2mm ID tubing won't slip off or blow out during vacuum or pressure applcations. Easily assembled wi

  • Bushing, Ace-Thred Connector

    Ace Glass

    Bushing connector for joining an Ace-Thred to a reduced end tube. Assorted bushing and o-ring materials.

  • Disposable Tubing Set

    Corning

    USP Class VI certified C-FLEX® tubing Accommodates both 2L and 4L bottles Male MPC connector with cap PureFit® tube clamp system Autoclavable *ADCF - Animal Derived Component Free **MPC - Medical grade Polycarbonate

  • Adapter, Chromatography Column to Tubing

    Ace Glass

    Internal threaded bottom drip adapter with or without flow regulator valve. 1/4"-28 or NPT internal threads. Supplied with packing support and o-ring. For use with all Ace-Thred chromatography columns.

  • EzyFit connector 0.50 mm ID x 1.3 mm OD x 700 mm long

    PerkinElmer

    Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.

  • EzyFit connector 0.25 mm ID x 1.3 mm OD x 700 mm long

    PerkinElmer

    This product has a quantity of 10. Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.

  • EzyLok Kit for Glass Concentric Nebulizers

    PerkinElmer

    Includes:  EzyLok Connector for 4mm Tubing  EzyLok 6mm Hose Adaptor  Nebulizer Hose Clip

  • EzyFit connector 0.75 mm ID x 1.3 mm OD x 700 mm long

    PerkinElmer

    EzyFit connector 0.75 mm ID x 1.3 mm OD x 700 mm long - Quantity 10

  • HF-resistant Internal Standard Kit including orange/blue flared end PVC pump…

    PerkinElmer

    In-line Standard Additions kits, one which includes a glass mixing chamber/combiner for solutions which do not contain HF and another which includes an inert mixing chamber/combiner. Both kits are completely modular so that damaged or worn components can easily be replaced. The heart of the kit is…

  • Condenser, West, with Ace-Thred Connectors

    Ace Glass

    …#15 Ace-Thred on 6433 Reactor Head, One-Piece Pressure Reactor or any vessel with a #15 Ace-Thred. Drip tip has a bump and groove that restricts blowout when secured with 7506-06 Bushing and O-Ring. Inlet/outlet have #7 Ace-Threds for use with Ace-Safe 5853 easy connect/disconnect tubing connectors.

  • Condenser, Allihn, With Ace-Thred Connectors

    Ace Glass

    Bulb type, approximately one bulb per 50 mm, with standard taper 24/40 inner and outer joint at bottom and top, #7 Ace-Thred and Ace-Safe PTFE hose connections on inlet and outlet with barb for 1/4" I.D. tubing. For replacement connectors, see 5853.

  • Glass 0.05 mL/min MicroMist Nebulizer for ELAN 5000/6x00/9000/DRCs/NexION 300…

    PerkinElmer

    …with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.25 mm I.D. x 700 mm long sample tubing. All MicroMist nebulizers glass are supplied with the EzyLok argon connector.

  • XK Columns

    GE Healthcare

    …solvents used in liquid chromatography of macromolecules. XK empty columns provide reliable and reproducible separations. The tube material is of borosilicate glass, which allows for visual inspection of the media bed. The columns are made of biocompatible materials that exhibit excellent chemical…

  • Glass 0.1 mL/min MicroMist Nebulizer for ELAN 5000/6x00/9000/DRCs/NexION 300/350…

    PerkinElmer

    …with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.25 mm I.D. x 700 mm long sample tubing. All MicroMist nebulizers glass are supplied with the EzyLok argon connector.

  • Glass 0.2 mL/min MicroMist Nebulizer for ELAN 5000/6x00/9000/DRCs/NexION 300/350…

    PerkinElmer

    …with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.25 mm I.D. x 700 mm long sample tubing. All MicroMist nebulizers glass are supplied with the EzyLok argon connector.

  • Adapter, Joint To Tube Compression, Vertical

    Ace Glass

    Glass standard taper and spherical joint adapters featuring a vertical ground glass sidearm. The sidearm is used to make tube compression fitting connection to a wide variety of flexible and rigid tubing using our 12709,12711,12715 & 12716 product families of fittings.

  • Standard Aqueous 50 mL Glass Twister Spray Chamber Assembly for Optima 2x00/4x00…

    PerkinElmer

    …Borosilicate glass Volume: 50 mL Low RSD's due to highly accurate construction Application uptake range 0.2 to 3.0 mL/min Produces smaller mean droplet size than standard spray chamber Positive stop for reproducible nebulizer insertion Convenient UniFit ™ drain connector This kit includes:…

  • Adapter, Joint To Tube Compression, Right Angle, Drip Tip

    Ace Glass

    Glass standard taper joint adapters featuring a drip tip and a right angle ground glass tube sidearm. The sidearm is used to make tube compression fitting connection to a wide variety of flexible and rigid tubing using our 12709,12711,12715 & 12716 product families of fittings.

  • Adapter, Joint To Tube Compression, Right Angle Tee

    Ace Glass

    Glass standard taper joint adapters featuring a drip tip and right angle tee ground glass tube sidearms. The sidearms are used to make tube compression fitting connections to a wide variety of flexible and rigid tubing using our 12709,12711,12715 & 12716 product families of fittings.

  • Adapter, Joint To Tube Compression, Vertical, Drip Tip

    Ace Glass

    Glass standard taper joint adapters featuring a drip tip and a vertical ground glass tube sidearm. The sidearm is used to make tube compression fitting connection to a wide variety of flexible and rigid tubing using our 12709,12711,12715 & 12716 product families of fittings.

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.