GC, Nucleic Acid, Agilent Technologies
-
HP-5ms
Agilent TechnologiesMeets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…
-
GS-Gaspro
Agilent TechnologiesBonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …
-
HP-Voc
Agilent Technologies• New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
DB-Wax
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …
-
DB-Tph 30m, 0.32mm, 0.25um
Agilent TechnologiesSpecifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable Agilent Technologies…
-
DB-1ht
Agilent Technologies100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …
-
DB-Waxetr
Agilent TechnologiesPolyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
HP-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
Se-30 And Se-54
Agilent TechnologiesSE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
CAM
Agilent TechnologiesBase deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …
-
Dbht-Simd 5m, 0.53mm, 0.15um
Agilent Technologies100% Dimethylpolysiloxane “Boiling point” phase for high temperature simulated distillation Durable stainless steel tubing 430°C upper temperature limit Distillation range of C6 to C110 Low bleed - even at 430°C Bonded and cross-linked Solvent…
-
HP-Ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …
-
DB-5.625
Agilent TechnologiesEquivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…
-
Columns Capillary HP-88 100m, 0.25mm id, 0.2um
Agilent Technologies(88%-cyanopropyl) aryl-polysiloxane 250/320°C upper temperature limits High Polarity Designed for separation of cis/trans fatty acid methyl esters Even better separation than DB-23 of cis-trans isomers Similar Phases: CP-Sil 88, SP-2560, SP-2340, SP-2330, BPX-70, BPX-90…
-
DB-210
Agilent Technologies(50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…
-
GS-Alumina
Agilent TechnologiesMost “polar” Alumina phase Aluminum oxide with proprietary deactivation Excellent general use column for light hydrocarbon analysis: C1 to C8 hydrocarbon isomers Separates C1-C4 saturated and unsaturated hydrocarbons Best for resolving cyclopropane from propylene …
-
DB-XLB
Agilent TechnologiesExceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…
-
DB-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…
-
DB-VRX
Agilent TechnologiesUnique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to…
-
DB-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…
-
DB-Petro 100m, .25mm, 0.5um, 5"Cage
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process…
-
Solvent Filters/Degassers
Agilent TechnologiesRemoving contaminants from solvents Degassing solvents in systems lacking on-line degassers Filtered solvents decrease piston wear from particulates Increase column life Eliminate pump downtime caused by air locks in check valves Filter into safe plastic-coated or…
-
DB-23
Agilent Technologies50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…
-
HP-Plot Q
Agilent TechnologiesBonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…
-
DB-1701p
Agilent TechnologiesLow/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701,…
-
DB-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…
-
HP-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C…
-
DB-624
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…
-
Duraguard Columns
Agilent TechnologiesColumns with “built in” guard columns, no press-fit connectors Minimize front-end contamination and increase column lifetime Aid in focusing sample onto the front of the column for better peak shape Minimize MSD contamination originating from the column (when used in…