GC, Equipment

Compare Tool

Select up to 3 products

1 - 32 of 107
Sort
View
Show
  • Agilent Technologies

    Specifically designed for the analysis of chlorinated pesticides and PCBs U.S. EPA Methods: 608, 508, 8080 Excellent inertness and recoveries without pesticide breakdown Bonded and cross-linked Solvent rinsable Exact replacement of HP-608 Similar Phases: SPB-608,…

  • Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • Hamilton PRP-X200 cation exchange HPLC columns are designed for rapid, high resolution separation of alkali and alkaline earth metals. The alkali metals and ammonium are completely resolved in less than five minutes, and the alkaline earth cations separate in under four minutes. Since the mobile…

  • Agilent Technologies

    10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked,…

  • quick-ship

    Agilent Technologies

    Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Bonded and cross-linked Solvent rinsable …

  • Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Tubes for general chromatographic analysis Tops are tooled for rubber stopper fit and tubes are fabricated with sealed-in coarse porosity fritted discs Outflow tubes eliminate the smearing of the definition bands of effluent caused by the tube being filled and solvent mixed before being…

  • Agilent Technologies

    100% Dimethylpolysiloxane “Boiling point” phase for high temperature simulated distillation Durable stainless steel tubing 430°C upper temperature limit Distillation range of C6 to C110 Low bleed - even at 430°C Bonded and cross-linked Solvent…

  • (88%-cyanopropyl) aryl-polysiloxane 250/320°C upper temperature limits High Polarity Designed for separation of cis/trans fatty acid methyl esters Even better separation than DB-23 of cis-trans isomers Similar Phases: CP-Sil 88, SP-2560, SP-2340, SP-2330, BPX-70, BPX-90…

  • Agilent Technologies

    Low/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701,…

  • Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50,…

  • Agilent Technologies

    Virtually equivalent to (50%-Phenyl)-methylpolysiloxane 320°/340°C upper temperature limit Very low bleed midpolarity, suitable for GC/MS Exhibits inertness to active compounds Enhanced mass spectral integrity Bonded and cross-linked Solvent rinsable Best…

  • Agilent Technologies

    • New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…

  • Agilent Technologies

    Undeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Agilent Technologies products are intended for sale/shipment within the US only. International customers…

  • Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…

  • Agilent Technologies

    Meets ASTM 6584 and EN14105 Standards 100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and…

  • Agilent Technologies

    Removing contaminants from solvents Degassing solvents in systems lacking on-line degassers Filtered solvents decrease piston wear from particulates Increase column life Eliminate pump downtime caused by air locks in check valves Filter into safe plastic-coated or…

  • Agilent Technologies

    Meets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …

  • Polymeric 100 Å columns for general reversed phase separations. pH stable from 1 to 13 Better sample recovery than silica-based columns (there are no silanol groups) Excellent durability (stable to any concentration of water or organic solvent)   Five particle…

  • quick-ship

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…

  • Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

Compare Tool

Select up to 3 products