Restek HPLC
-
Solvent Debubbler
RestekBubbles in an LC system can cause check valve malfunctions and pump cavitation, seriously affecting pump performance. The debubbler removes bubbles from the fluid stream before it enters the pump. Special geometry at the base of the housing allows bubbles entrained in the inlet fluid stream to…
-
This high-pressure cup-type filter can be used in fluid streams operating to 15,000 psi (103,421 kPa). The cup-shaped filter elements have a large (2.5 cm 2 ) surface area to give long operating lifetime. Mounted in screw-type adapters, they are easily removed for cleaning. Normally, backflushing…
-
Fluid resistor technology eliminates adjustments to capillary tubing for optimizing split ratio. Wide range of interchangeable resistors available. Fixed Flow Splitters for HPLC & LC-MS Split ratio not affected by changes in viscosity or pressure High operating pressure limit:…
-
Please note: Not compatible for use with Outlet Cap and Gold Seal Assembly Tool (cat.# 24989).
-
A good connection between HPLC components is necessary for trouble-free chromatography. Secure-Fit connectors from Restek and Selerity Technologies ensure a consistent, leak-free seal—and they eliminate excess dead volume! An internal spring mechanism holds the capillary tubing at the proper…
-
Bio-Safe columns are biocompatible and precision-machined from virgin PEEK (polyetheretherketone), a strong, inert polymer material. Completely biocompatible 100% metal free Stable to 8,000 psi Product Specs 4.6 mm ID x 30 mm length column with end fittings 2.0 µm frits
-
Includes: pump seals (4); backup rings (4); O-rings (4)
-
HPLC Column Tubing
RestekRestek tubing is manufactured from fine, chromatographic-grade 316 stainless steel. It is corrosion resistant, ultrasonically cleaned, and passivated. We polish the tubing and promise a burr-free cut. You can use this tubing immediately—there is no need for additional treatment.
-
For start-up and maintenance in all HPLC systems. The stainless steel survival kit contains a wide range of tubing, fittings, and tools necessary to set up and maintain your HPLC system: a selection of lengths and IDs of 1/16-inch tubing, plus nuts, ferrules, a ValvTool wrench, and a…
-
Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed of PTFE material with an additive that reduces their tendency to "cold flow" and improves their wear characteristics. PTFE seals are more resistant to any HPLC solvent…
-
Whether you need to replace system tubing as part of your troubleshooting or want to reduce the dwell volume of your system as you move to narrower columns, Restek has the quality tubing in the lengths and IDs you need. Each ID is color coded, so it is easy to identify and replace correctly. Tubing…
-
Prevent the particulates and microbial growth in your LC solvents from entering your instrument with the new Restek Bluestem glass solvent filter. Restek Bluestem glass solvent filter provides clean mobile phase to extend the life of columns and pump seals 15 µm borosilicate glass…
-
Precut, micropolished tubing and preseated fittings for quick, easy maintenance of your Agilent HPLC systems Meet or exceed manufacturer's performance.
-
Restek Pack in a Box Kit
RestekRestek’s Pack in a Box kit is a complete column-packing system. Everything you need to pack your own analytical HPLC columns is included (contents detailed below). The packing pump is electric, so no pressurized air is required. AC input requirement: 100-240 VAC, 50/60 Hz. 10,000 psi maximum…