PerkinElmer, NEW! Life Science
-
Ryton Scott Spray Chamber for Avio 200/500
PerkinElmerThe spray chamber is an integral part of the sample introduction system responsible for filtering the sample mist to permit the appropriate droplet size distribution to reach the plasma. It is corrosion resistant and is inert to most mineral acids, including hydrofluoric acid, aqua regia, and all…
-
System 2 electrodeless discharge lamp for the detection of elemental Rubidium (Rb). Note: PinAAcle ™ instruments require the purchase of an EDL driver assembly, part number 03030997, for each of the lamp positions to be used. Electrodeless Discharge Lamps for greater brightness (EDLs) are…
-
Edwards 45 Vacuum Pump Oil
PerkinElmerThe Edwards 45 1 Liter vacuum pump oil features a non-toxic, non-corrosive formulation and is used in mass spectrometry applications. The presence of hydrocarbon synthetic polymer provides good chemical inertness, temperature stability and low vapor pressure.
-
Tungsten Lamp for LAMBDA 365
PerkinElmerProvide the best wavelength coverage across the working range of the spectrometer for consistently high performance. Changing tool order N4102048.
-
Brownlee Spheri-5 ODS is based on a small pore silica, polyfunctional, optimized for separating small molecules. Requires holder P/N 07150015 without guard column or P/N 07150017 with a guard column.
-
Nickel (Ni) Lumina Hollow Cathode Lamp
PerkinElmerSingle Element Lumina hollow cathode lamp (HCL) for the detection of elemental Nickel (Ni). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and…
-
Cadmium (Cd) AAnalyst Coded Intensitron Adapter
PerkinElmerNote: System 2 EDLs come with two coding plugs: a plug compatible with the Aanalyst series of instruments and a coding plug compatible with earlier instruments having coding capability, for example the Models SIMAA 6000, 5100(PC), 4110 ZL, 4100 ZL, 4100, 3300, 2100 and 1100(B).
-
This PTFE-coated Viton o-ring, with an inner diameter of 6.07 mm and width of 1.78 mm, is used for the internal injector support adapter with ELAN 6000, 9000, DRC II, and DRC-e, and NexION 300 and 350 ICP-MS series instruments.
-
Universal BIO C18PP 5UM 250X4.6MM HPLC Column
PerkinElmerUniversal BIO C18PP 5UM 250X4.6MM HPLC Column
-
This baffled cyclonic spray chamber, made of borosilicate glass, is an integral part of the sample introduction system responsible for filtering the sample mist to permit appropriate droplet size distribution to reach the plasma. The spray chamber features a sand-blasted neck with EZ seal fitting…
-
-
Electron Capture Detector (ECD) Amplifier for PerkinElmer AutoSystem Series GCs
-
Solution fitting, 0.5 mm PTFE with adapter F2-50
PerkinElmerSolution fitting, 0.5 mm PTFE with adapter F2-50
-
System 2 electrodeless discharge lamp for the detection of elemental Germanium (Ge). Note: PinAAcle ™ instruments require the purchase of an EDL driver assembly, part number 03030997, for each of the lamp positions to be used. In addition this element requires the use of a nitrous oxide-acetylene…
-
Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
Cyclo Splitter Split Liner 4mm
PerkinElmerCyclo Splitter Split Liner 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length.
-
Temperature range 40°C to 360°C Equivalent to USP G3
-
Consumables Kit for ELAN DRC-e/9000
PerkinElmerThis kit includes: ELAN Cross-Flow Nebulizer Tip Kit, Qty. 1 (N8120515) 0-Slot Quartz Torch, Qty. 1 (N8122006) 2.00 mm I.D. Alumina Injector, Qty. 1 (N8126041) Nickel Skimmer Cone, Qty. 2 (WE021137) Nickel Sampler Cone, Qty. 2 (WE021140) Sampler Cone O-Ring, Qty. 5 (WE012687) Series II…
-
-
Brownlee Aquapore C8 columns are based on wide pore 300 7µm silica, for the analysis of large bio-molecules. Requires holder P/N 07150013 without guard column. If a guard column is being used P/N 07150018 and P/N 07150002 will also be required.
-
Heat Shield Seal Assembly & Window
PerkinElmerThe PerkinElmer seal assembly and window comes with a FPD detector and consists of a heat shield that protects the seal from extreme temperatures.
-
Elite-5 capillary column, 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C
-
Iron (Fe) Lumina Hollow Cathode Lamp
PerkinElmerSingle Element Lumina hollow cathode lamp (HCL) for the detection of elemental Iron (Fe). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and…
-
The Merlin MicroSeal injector port septa is a unique replacement septa employing a two-step sealing system and an advanced elastomer material. Because the syringe needle does not pierce the septa, there is no debris and ghost peaks are greatly reduced. The MicroSeal septa also reduces the incidence…
-
0-Slot Quartz Torch for Optima 8x00
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
SPE Columns Selection Kit, Removal of Polar Compounds from Aqueous and Organic Matrix enables quick column selection for development of reproducible and repeatable SPE methods. Media Weight: 500 mg Volume: 3 mL Quantity: 30
-
-
Volatile Organics Combination Blend
PerkinElmerVolatile Organics Combination Mix Analyte Mixes A,C & D. 54 certified analytes 1. 2 mL @ 2000µg/ml - in P & T methanol 2000 µg/ml - Benzene 2000 µg/ml - Bromobenzene 2000 µg/ml - Bromochloromethane 2000 µg/ml - Bromodichloromethane 2000 µg/ml - Bromoform 2000 µg/ml -…
-
Collector Head Assembly
PerkinElmerThe PerkinElmer collector head assembly is designed to use with FID detector in the gas chromatography technology.
-
Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
High-Purity Brass Regulator (Single Stage), CGA-350, Use:He, Ar. PerkinElmer offers both single- and dual-stage regulators. All regulators are supplied with standard CGA fittings. We recommend that you consult your local gas supplier first to determine the proper tank regulator required. All…
-
Elite-5MS capillary column 60m x 0.32mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases