PerkinElmer, GC Instruments, Parts and Supplies, Vectors & Kits
-
Inlet liners for split injection have mixing chambers with tortuous flow paths to allow full vaporization of the sample. Deactivating the surface of these liners prevents active compounds from degrading. Packing the liner with wool will trap non-volatile residue and prevent column contamination…
-
-
-
PCB Kit for Method 8082
PerkinElmerWe offer standard solutions to meet your environmental analysis requirements.
-
Detector Lower Body
PerkinElmerThe PerkinElmer detector lower body comes with a flame photometric detector and is mainly used in laboratory and manufacturing factories.
-
Marathon Filament for GC/MS/MS Systems
PerkinElmerThe Marathon Filament is a revolutionary technology developed exclusively by PerkinElmer GC/MS and GC/MS/MS systems, delivering long life even under the most difficult chromatography conditions. It is a direct replacement of the previous rhenium filament - no system changes required. At…
-
Internal Standard for Method 524.2
PerkinElmerMethod 524.2 Internal Standard. 1 certified analyte. 1.2 mL @ 2000µg/ml - in P T methanol 1000 µg/ml - Fluorobenzene
-
Blue GC Inlet Liners
PerkinElmerPSS splitless deactivated glass liners 1.25 mm I.D. x 4.0 O.D. x 86.2, with deactivated wool 5/pack.
-
Decapper Jaw set for the High Performance Crimper. It fits standard 11 mm caps, is suitable for all steel and magnetic caps, and a wide range of seal thicknesses.
-
Shoulder Pin
PerkinElmerThe PerkinElmer shoulder pin comes with a PID detector and is mainly used in laboratory and manufacturing factories.
-
-
Of the three ferrule types available graphite is the softest, making it less damaging to capillary columns when overtightened. Graphite seals easily and does not stick to glass columns. Recommended for use with capillary columns. Temperature limit is 450 °C. Note: 0.25-0.32mm inner diameter.…
-
Gas Chromatography Connector
PerkinElmerThe PerkinElmer gas chromatography connector consists of a 9/16 Inch hex nipple and the 1/4 Inch MNPT thread provide a tight connection. Solid brass construction offers added strength and durability.
-
Heat Shield Seal Assembly & Window
PerkinElmerThe PerkinElmer seal assembly and window comes with a FPD detector and consists of a heat shield that protects the seal from extreme temperatures.
-
Silanized Glass Wool (50 g)
PerkinElmerSilanized glass wood is made for use with Automated Thermal Desorber (ATD) 400.
-
Detector Receiver
PerkinElmerThe PerkinElmer detector receiver with a 1/8 Inch fitting comes with a PID detector and is compatible wit AutoSystems.
-
2mm Split Mode Quartz Liner for Programmed-Temperature Split/Splitless Inlet System
-
Deionizer Bag
PerkinElmerThe PerkinElmer deionizer bag is compatible to use with the NM-H2 plus generator.
-
Fine Tip Detector Probe
PerkinElmerThe PerkinElmer fine tip detector probe is an important component of portable electronic gas leak detector and helps in trace analysis.
-
-
4mm Quartz Liner for Split Operation or Large Volume Splitless Injection
-
-
Bakeout Disk
PerkinElmerThe PerkinElmer bake out disk comes with a PID detector and is mainly used in laboratory and manufacturing factories.
-
Detector Amplifier
PerkinElmerThe PerkinElmer detector amplifier comes with a FPD detector and is compatible to use with FPD add-on kit.
-
Battery: LiFePO4 6. 4 Volt Rated 1500 Charge Cycles Tested to EN62133 and UN DOT Very low self-discharge Direct plug connection to board PTC’s integral to battery Crimper can operate while battery is charging. Motor: Stall torque 1400 g cm. Control Buttons: Top-mounted keypad…
-
Polynuclear Aromatic Hydrocarbons for Method 625
PerkinElmerWe offer standard solutions to meet your environmental analysis requirements.
-
-
Acid Surrogate for Method 8270C
PerkinElmerWe offer standard solutions to meet your environmental analysis requirements.
-
We offer standard solutions to meet your environmental analysis requirements.
-
Size: 11 mm Pack Size: 50/pack
-
Replacement Septum Purge
PerkinElmerThe PerkinElmer replacement septum purge is used in the programmed-temperature split/split less injector system.
-
Trap Filter Disc
PerkinElmerThe PerkinElmer trap filter disc makes use of gas chromatography and is designed to use with PerkinElmer TurboMatrix thermal desorption instruments.