Hamilton, Syringes, Non-Sterile
-
Metal and Kel-F® hub 304 stainless steel needle Standard 2” length Use with Luer Tip and Luer Lock syringes sold without needle or for Luer adapters. Nickel-plated brass or Kel-F (CTFE) hubs fit both male and female Luer connectors.They allow quick change of needle and use…
-
1000 Series Gastight Syringes
HamiltonTeflon ® PTFE tipped plungers Replaceable barrels, plungers and tips mL sizes For use with liquids or gases. Features a precision-machined Teflon plunger tip which, when wetted, forms an interference fit with the inner diameter of the glass barrel, achieving the seal required for…
-
700 Series Microliter Syringes
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. The stainless steel plunger is manufactured to fit the glass barrel with a tolerance less than three thousandths of a millimeter, resulting in unsurpassed syringe life. This series of syringes is ideal for dispensing volumes from…
-
Gastight Syringes For HP 7683/7673 GC Autosamplers…
-
Teflon ® PTFE tipped plungers Replaceable barrels, plungers and tips Cemented or removable needles For use with liquids or gases. Features a precision-machined Teflon plunger tip which, when wetted, forms an interference fit with the inner diameter of the glass barrel to achieve the seal…
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Gauge: 25s Length: 1.97” Point style: 3 Syringes feature removable needles; Teflon ® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. 1800 Series has adjustable friction, which controls plunger resistance, and plunger stop helps prevent blow-out. …
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Syringe 725Npt5 250ul (22S/2"/5)
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. Stainless-steel plunger manufactured to fit the glass barrel with a tolerance smaller than 100 millionths of an inch, resulting in…
-
Shimadzu AOC-9 Syringes
HamiltonHamilton offers a wide variety of syringes specifically designed for Shimadzu autosamplers that require 43 mm needle lengths as well as standard 51 mm lengths.
-
Syringes
HamiltonThe Hamilton 700 series 100 uL syringe is suitable for use with small removable needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 115 degree F.
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Removable Needle
HamiltonSmall Hub Removable (RN) needles can be used with Removable Needle (RN) syringes that are 100 µL and smaller. Standard needle length is 2 in / 51 mm. Removable (RN) needles are available in convenient six packs. Custom lengths and point styles are available.
-
Custom HAT NDL Syringes
HamiltonAvailable options: Custom Length: 0.375 to 12 in Point Style: 2, 3, or 4
-
Length: 1.71 HP point style See 8928C31 series for replacement needles for removable needle syringes.
-
Syringes
HamiltonThe Hamilton gaslight syringe features ChemSeal (C, 1/4 Inch - 28) termination. This syringe model offers borosilicate glass, PTFE and PFA fluid path. It can be used at a temperature rating of up to 10 to 115 degree C.
-
Digital Syringes
HamiltonThe most accurate manually operated syringes available Consistent plunger position LCD NIST Traceable Ergonomically designed syringes have a fine adjustment thumbwheel for easy volume control. Plunger drag adjustment optimizes the rate of plunger movement to the…
-
-
Removable needles Length: 2.756” Point style: 3 Replacement needles available on special order.
-
Point styles 2 and 3 Standard 2” length Needles seat precisely to the zero graduation mark of the syringe. They are autoclavablewhen disassembled. They allow the use of different specification needles with the same barrel. The small ‘s’ next to the gauge number indicates…
-
GC On-Column Syringes
HamiltonRemovable needles Fused silica needle Length: 100 mm (8928C59: 115 mm); Point style: 3. Syringes 8928C65 to C68 and C77 to C83 are gas-tight.
-
Removable needles Length: 1.71” HP point style See 8928C31 series for replacement needles.
-
Chromatography Syringes
Hamilton7000 Series Modified Microliter® Removable needles Replaceable barrels and parts No dead volume Positive displacement syringe for use with liquids. A tungsten plunger wire travels inside the needle, eliminating dead volume. Knurled hubs are used exclusively on the 7000…
-
These syringes are designed to work with Valco VISF-1 HPLC injection valves. They have PTFE plunger tips that create tight connection between syringe barrel and plunger allowing for liquid or gas sampling. Removable Needle (RN) - needles are removable and are a Hamilton-specific design …
-
600 Series Microliter Syringes
HamiltonHamilton's '600 Series' syringes are a rugged, durable, and long lasting half stroke version of Hamilton’s original 700 series syringes. They have a reinforced plunger which prevents plunger bending. Each plunger is individually fitted to the glass barrel and cannot be…
-
Cemented needles on 8928B58-64 Removable needles on 8928B67 Length: 2” Point style: 2 See 8928C40 for needle for 8928B67.
-
Length: 2” Point style: 3 For use with Rheodyne, Valco™ VISF-2, Beckman®/Altex and SSI injection valves. Syringes are available with cemented or removable needles and feature Teflon® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. See…
-
Purge & Trap Syringes
HamiltonDesigned for the analysis of drinking water samples according to EPA purge and trap concentration techniques Easy-to-remove syringe plunger for loading water samples into syringe barrel. Internal standard or surrogate sample can be added directly through twist valve.
-
Removable needles Length: 1.71” HP point style See 8928C19 series for replacement needle kits.
-
1700 series, gastight syringes with cemented needles. Length: 1.71 23s-26s gauge AS Point Style
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…