CHEMetrics, Supplies

Compare Tool

Select up to 3 products

1 - 32 of 154
Sort
View
Show
  • quick-ship

    CHEMetrics

    USEPA-approved Mercury-free COD kits CHEMetrics’ leakproof reagent vials contain premeasured solutions of sulfuric acids and potassium dichromate. To perform the COD determination, the analyst simply removes the Teflon® lined screw cap from the vial, adds sample to the vial,…

  • WARNING! This product can expose you to chemicals including ethylene glycol, which is known to the State of California to cause birth defects or other reproductive harm.  For more information go to www.P65Warnings.ca.gov . Shelf life = 8 months

  • Hydrogen peroxide is a strong oxidizing agent with a variety of uses. Applications include the treating of industrial effluents and domestic waste and serving as a disinfectant in aseptic packaging. The Ferric Thiocyanate Method Reference: D. F. Boltz and J. A. Howell, eds.,…

  • Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-60 & 60-600 ppm MDL: 10 ppm Method: Direct Nesslerization …

  • Phosphorus occurs naturally in rock formations in the earth's crust, usually as phosphate. High phosphate concentrations in surface waters may indicate fertilizer runoff, domestic waste discharge, or the presence of industrial effluents or detergents. Although phosphates from these sources are…

  • CHEMetrics

    Ethylene glycol and propylene glycol are the primary ingredients in commercially-available antifreezes. They are used with various corrosion inhibitors to protect metal surfaces in cooling water systems. CHEMetrics glycol kits are used to monitor potable waters for glycol contamination…

  • Because of its strong oxidizing properties, chlorine is an excellent biocide used to treat potable waters, municipal wastes, and swimming pools. When used to treat potable water, chlorine helps alleviate the adverse effects of iron, manganese, ammonia, and sulfide. The Maximum Residual Disinfectant…

  • WARNING! This product can expose you to chemicals including ethylene glycol, which is known to the State of California to cause birth defects or other reproductive harm.  For more information go to www.P65Warnings.ca.gov .

  • Hydrazine is a powerful reducing agent that is used in various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out…

  • Hydrazine is a powerful reducing agent that is used in various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out…

  • Sulfides are naturally present in ground waters as a result of leaching from sulfur-containing mineral deposits. Surface waters do not usually contain high sulfide concentrations. Sulfides result from the decomposition of organic matter, from bacterial sulfate reduction under anaerobic conditions…

  • Method: Rhodazine D WARNING! This product can expose you to chemicals including methanol, which is known to the State of California to cause birth defects or other reproductive harm.  For more information go to www.P65Warnings.ca.gov

  • The CHEMetrics vacu-vials instrumental kit is an ideal thing to have in any chemical laboratories, healthcare units or medicinal facilities for a wide range of purposes such as scientific research and development.

  • CHEMetrics

    The CHEMetrics sulfide comparator is a suitable thing to have in any chemical laboratories, medicinal facilities or healthcare units for a wide range of applications such as scientific research and development.

  • Nitrite, an intermediate in the nitrogen cycle, is formed during the decomposition of organic matter but readily oxidizes to form nitrate. These processes occur in wastewater treatment plants, water distribution systems, and natural waters. Nitrites are useful as corrosion inhibitors,…

  • CHEMetrics

    The CHEMetrics sulfide comparator is a perfect thing to have in any chemical laboratories, medicinal units or healthcare facilities for a wide range of applications such as scientific research and development.

  • CHEMetrics

    The CHEMetrics peracetic acid CHEMets kit and peracetic acid comparator are used to determine various levels of peracetic acid in liquids. These are easy to use and ensure accurate testing. Application: For the Analysis of Peracetic Acid

  • Detergents can be introduced into the water supply by industry, soap manufacturers, and private households. Environmental analysts often include a determination of anionic detergents when assessing surface water pollution. The Methylene Blue Method References: USEPA Methods for…

  • Low-level ammonia nitrogen may be naturally present in water as a result of the biological decay of plant and animal matter. Higher concentrations in surface waters can indicate contamination from waste treatment facilities, raw sewage, industrial effluents (particularly from petroleum refineries),…

  • Persulfate is a strong oxidizer that is commonly used for clarifying swimming pools and spas and for the destruction of a broad range of soil and groundwater contaminants. Sodium persulfate is frequently used for environmental applications. The Ferric Thiocyanate Method Reference: D.F.…

  • Surface and ground waters rarely contain more than 1 mg/L of soluble or suspended manganese. Manganese can act as an oxidizing or a reducing agent depending on its valence state. Manganese is also used in the manufacture of batteries and as an alloying metal in the manufacture of steel and…

  • Hydrogen peroxide is a strong oxidizing agent with a variety of uses. Applications include the treating of industrial effluents and domestic waste and serving as a disinfectant in aseptic packaging. For the food and beverage industry, CHEMetrics Hydrogen Peroxide CHEMets® and…

  • Chloride is the most common inorganic anion found in water and wastewater. The Maximum Secondary Contaminant Level for drinking water for chloride is 250 mg/L. Natural sources of salt are the ocean and various salt deposits above and below ground. Chloride is very corrosive to most metals in…

  • Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-1000 & 1000-10,000 ppm MDL: 100 ppm Method: Direct Nesslerization …

  • Hexavalent chromium salts are used in numerous industrial processes. They are also used extensively as corrosion inhibitors in open and closed cooling water systems. The Diphenylcarbazide Method References: APHA Standard Methods, 23rd ed., Method 3500-Cr B - 2009. ASTM D 1687-02,…

  • The CHEMetrics vacu-vials instrumental test kit is an ideal thing to have in any chemical laboratories, healthcare units or medicinal facilities for a wide range of purposes such as scientific research and development.

  • Hydrazine is a powerful reducing agent that is used in various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out…

  • CHEMetrics

    Range: 0-15,000 ppm (HR+) Not USEPA Approved* Method: Dichromate Reactor Digestion Kit comes in a cardboard box and contains everything needed to perform up to 97 tests (except distilled water): 98 vials and instructions. All COD Kits require the use of a Digestor Block and the…

  • Nitrate is the most completely oxidized form of nitrogen. It is formed during the final stages of biological decomposition, either in wastewater treatment facilities or in natural water supplies. Low-level nitrate concentrations may be present in natural waters. However, a Maximum Contaminant Level…

  • Qty. per pack: Two 10mL bottles of A-1404 Stabilizer Solution Two 10mL bottles of A-1405 Catalyzer Solution Two 10mL bottles of A-1406 Activator Solution Shelf-life: 8 months The A-1410 Accessory Solutions Pack supplies enough of each solution to perform approximately 80 tests.

  • Cyanide is used in many chemical and refining processes. It is found in effluent from electroplating and metal cleaning operations, coke ovens, steel manufacturing facilities, and gas scrubbers. Although cyanide can be safely removed by alkaline chlorination, its acute toxicity to aquatic life…

  • Chlorine dioxide is used as an oxidizing microbiocide in industrial cooling water treatment, the dairy industry, the meat industry, and many other food and beverage industry applications. It is used as a bleaching agent in the pulp and paper industry, and as a disinfectant in municipal water…

Compare Tool

Select up to 3 products