Cannon Instrument, Chemicals

Compare Tool

Select up to 3 products

HomeAll Products

Chemicals Cannon Instrument

1 - 32 of 39
Sort
View
Show
  • Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…

  • CT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…

  • Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…

  • quick-ship

    Cannon Instrument

    Contains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.

  • The Cannon Instrument probe is suitable for use with Dostmann dual channel digital thermometers for various viscometer models. You can choose ideal replacement part or accessory which ensures smooth functioning of thermometer units.

  • Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • Cannon Instrument

    Tapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.

  • Wide temperature range 20°C to 150°C Easy temperature setting Insulated for precise solid-state temperature control Multiple safety features Ideal for temperature control of other instruments which must be viewed while immersed in a constant temperature bath. The top…

  • Cannon Instrument

    All Cannon viscometer holders are designed to fit holes 51 mm (2 in.) in diameter. Rubber holders are made of neoprene rubber.  Plastic holders hold the viscometer firmly with a spring clip.  Metal holders are constructed of chrome-plated machined brass.  A handle permits…

  • Ideal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features of…

  • Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…

  • Calibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic…

  • Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…

  • CANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…

  • Quick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…

  • Inexpensive, compact source of low-level pressure and vacuum Fused circuit and grounded plug ensure safe operation Multiple fittings kit and polyurethane tubing are provided Oilless diaphragm pump operates quietly to produce a continuous pressure of 35 psi or an adjustable,…

  • The Dostmann P795 dual channel digital thermometer is a precision hand held device for accurate temperature measurement. Dual channel technology allows simultaneous display of two readings or a differential result to meet the needs of automated viscosity applications, such as side-by-side kinematic…

  • Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…

  • Four Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…

  • Cannon Instrument

    Thermoelectrically cool baths up to 15°C below ambient 1/10 the size of standard refrigeration units Power consumption of only 250 watts Simple to operate with low maintenance Cooling fans are the only moving parts CBC bath coolers consist of a thermoelectric cooling unit and a separate…

  • Cannon Instrument

    With three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…

  • Designed specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…

  • Cannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…

  • Cannon Instrument

    CANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…

  • Cannon Instrument

    Programs are supplied on a 3.5” disk. The programs are designed to be user-friendly (they are accessed through a convenient menu system) and are provided with a detailed operator’s manual. The calculations performed include the following: Blending of oils- the W.A. Wright…

  • Microprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…

  • Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…

  • Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…

  • Calibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of…

Compare Tool

Select up to 3 products