The portable WTW ProfiLine meter series is available in three (3) series versions, the 3110/3205-Basic series, 3210-Professional series and 3310-Advanced series, each with a distinct level of sophistication for the independent measurement of pH, conductivity, or dissolved oxygen. All versions have…
-
-
Robust, membrane-covered galvanic dissolved oxygen sensor for applications in flowing waters, fish hatcheries, aeration basins and more fields. With screw-on protection. The special membranes achieve stable measured values, especially in the aeration basin and similar applications with strongly…
-
Armings with protective baskets made of stainless steel or plastic to use TetraCon® conductivity measuring cells as well as CellOx® oxygen sensors. Protection of the sensors against damage Robust design Easy mounting
-
The portable WTW ProfiLine meter series is available in three (3) series versions, the 3110/3205-Basic series, 3210-Professional series and 3310-Advanced series, each with a distinct level of sophistication for the independent measurement of pH, conductivity, or dissolved oxygen. All versions have…
-
The portable WTW ProfiLine meter series is available in three (3) series versions, the 3110/3205-Basic series, 3210-Professional series and 3310-Advanced series, each with a distinct level of sophistication for the independent measurement of pH, conductivity, or dissolved oxygen. All versions have…
-
Ion selective electrodes for the electro-chemical concentration determination of selected ions - combined electrodes as well as half cells available. Cost-effective process with few samples Wide selection of electrodes for different ions Easy handling by combined electrodes …
-
GLP functions QA functions Laboratory oxygen meters have a large multifunction display. The inoLab Oxi 7300® and Oxi 7400® meters offers a range of automated functions such as air pressure correction, temperature compensation and OxiCal rapid calibration. The inoLab740…
-
The calibration and storage containers for the WTW oxygen sensors are suitable for the standard conform calibration (DIN ISO 5814 or DIN ISO 17289: 2014-12) with water steam saturated air as well as for storage of the sensors to protect the sensitive membrane.
-
Test resistors and calibration solutions to test the meters with conductivity function as well as to calibrate the system from the device and conductivity measuring cell Optimal measuring safety by PTB/NIST traceable standard solutions Easy device check by highly precise test resistors …
-
IDS Depth Probes
WTWMPP IDS – the digital multi-parameters (up to three main parameters) depth probes with built-in depth measurement to use in profile measuring Depth measurement of pH, conductivity, dissolved oxygen, turbidity - up to three main parameters simultaneously, including depth and…
-
SenTix®: Standard electrodes with gel and precision electrodes with liquid gel electrolyte for pH measurements in lab applications and in the field Maintenance-free gel reference system across the entire product life Quick repsonse time by good connection to the medium for electrodes…
-
The FDO® 925’s small dimensions make it suitable for lab and process . The flow-free, easy-to-clean, beveled membrane allows it to be used in containers with low sample volumes. Low oxygen concentrations under 1 mg/l can also be detected accurately. The fast and flow-free FDO®…
-
WTW offers decades of expertise in high quality, rugged conductivity cell technology, and now the new IDS conductivity cells build upon this proven technology including the automatic transfer of the cell constant feature to eliminate operation errors. Two models are available to cover the entire…
-
IDS ORP electrodes are used to measure oxidation or reduction potentials in waterous solutions - with integrated temperature sensor Safe measured values due to signal processing in the sensor Integrated temperature sensor NTC 30 kOhm for precise value documentation Best possible GLP…
-
Membrane-covered galvanic dissolved oxygen sensors to measure in water and waterous solutions - low-maintenance and no polarization time, required For instant measurement Easy air calibration with water vapor saturated air in the calibration vessel User friendly and long operation…
-
Multi 3320: The Environmental Expert The Multi 3320 for measurement of pH, ORP, ISE, conductivity and dissolved oxygen (electro chemical) is a perfect meter for environmental applications in ground and surface water, aqua culture, waste water treatment plants and much more. An integrated ISE…
-
Electrodes 4258A53 electrode allows ORP measurements to be performed with all WTW pH/mV meters. Requires 4258A57 cable for use with Inolab Meters.
-
Conductivity measuring cells with graphite electrodes in two and four pin models for standard measurements in aqueous solutions in the field and in the lab No measuring errors due to cable, polarization effects or changes of the electrical edge field Highest precision and linearity …
-
The WTW MultiLine IDS series of meters are the first of their kind, redefining the way electrochemical measurements are conducted. The innovative, digital technology of the MultiLine IDS series eliminates the need for dedicated meters for specific parameter measurements; now, measuring is simply a…
-
pH/Cond 3320: Professional pH/conductivity meter with 2 inputs (DIN, 8 pin socket), backlit graphic display, for mobile application with data logger and USB interface. Single instrument including short instruction manual, CD-ROM and batteries, cable. pH/Cond 3320 SET 2: …
-
Flow measuring cells by WTW for medium and high conductivity are suitable for extensive measuring series in the lab but also for the maintenance and measurement of cleaning solutions in special systems. Suitable for flow-through measurement in the lab For medium and high conductivity …
-
Professional pH/mV/ISE meter with DIN socket, backlit graphic display, for mobile application with data logger and USB interface. Single instrument including instruction manual, CD-ROM and batteries, cable
-
Specialists for all cases - pH electrodes for special applications can determine the pH value of surfaces, suspended solids, suspensions and much more Wide selection of special measurements Adaptation to the sample consistency by special glass membranes Optimal measuring accuracy by…
-
Flow vessels for WTW conductivity measuring cells are perfectly designed to perform measurements without the interference of carbon dioxide through the air or to examine the conductivity of solutions in closed circuits. Important: The overpressure in the system must not exceed 0.5 bar.
-
OxiTop-i B - OxiTop®-i measuring head blue, menu-operated, with backlit graphic LCD, control LED, operating buttons, for direct BOD readings, volume pre-selection, measurement duration between 1 and 7 days selectable, display of measuring curve, display of current readings.
-
pH/ORP electrodes are the most commonly used electrochemical sensors. At the same time, they provide the most sensitive measuring signals and must be serviced and calibrated on a routine basis. The concept of IDS sensors precisely takes effect here. Digital data transfer without interferences…
-
The StirrOx® G not only ensures the necessary flow with its stirrer, but also the mandatory mixing of the samples. It fits perfectly into the funnel of the Karlsruhe bottles or with a funnel set also in Winkler bottles.