Agilent Technologies, Gas Chromatography Columns, Columns

Compare Tool

Select up to 3 products

1 - 32 of 121
Sort
View
Show

Agilent Technologies

Efficient LC Solutions that deliver the fast, reproducible results you need


  • Agilent Technologies

    Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable Agilent Technologies…

  • Agilent Technologies

    Ultra 1: 100% Dimethylpolysiloxane Ultra 2: (5%-Phenyl)-methylpolysiloxane Non-polar Bonded and cross-linked Solvent rinsable HP-1 and HP-5 with tighter specifications for retention index and capacity factors Temperature range: -60° to 325°/350°C …

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    Agilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…

  • Agilent Technologies

    100% Dimethylpolysiloxane Temperature limits: -60 to 280°C Similar Phases: OV-101, SP 200, DB-1, HP-1 Because HP-101 columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only.…

  • Agilent Technologies

    Agilent J&W DB-35ms Ultra Inert is a mid-polar column, for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing. DB-35ms Ultra Inert quantifies components at a lower level, with broader linearity and optimized…

  • Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…

  • Agilent Technologies

    HP-INNOWax is a polyethylene glycol (PEG) stationary phase that features high polarity and high upper temperature limits. It is a close equivalent to USP phase G16 and is targeted at food, flavor, and fragrance applications. The improved line of Agilent J&W HP-INNOWax GC columns utilizes…

  • Agilent Technologies

    (50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…

  • Agilent Technologies

    Polyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • Agilent Technologies

    100% Dimethylpolysiloxane Configured for the analysis of petroleum process products PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1 100 psi regulator required to reach optimum…

  • Agilent Technologies

    Exceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…

  • Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • Agilent Technologies

    Least “polar” Alumina phase Aluminum oxide deactivated with KCl Good choice for light hydrocarbon analysis Good resolution of propadiene and butadiene from ethylene and propylene streams Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT,…

  • Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…

  • Agilent Technologies

    The J&W DB-624 capillary Gas Chromatography (GC) column is designed for the analysis of volatile organic pollutants by GC and GC/MS. The DB-624 column is recommended for residual solvent analysis by USP Monograph , and Environmental Protection Agency (EPA) methods for volatile organic compounds…

  • Agilent J&W VF-1ms is a highly inert, nonpolar, 100% dimethylpolysiloxane phase column that provides increased sensitivity for a broad array of applications, particularly for energy, pharmaceutical, and environmental analysis. The column has an ultra-low-bleed specification of 1 pA at 325 °C (30 m,…

  • Agilent Technologies

    J&W DB-5ms is a non-polar phenyl arylene polymer gas chromatography (GC) Column, virtually equivalent to (5%-phenyl)-methylpolysiloxane, featuring an excellent signal-to-noise ratio for analytical applications. This improved performance gives better sensitivity and mass spectral integrity, and…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35,…

  • Agilent Technologies

    DB-624 Ultra Inert columns are designed for trace analysis in environmental volatile organic compound applications. Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place…

  • Agilent Technologies

    Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to…

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…

  • quick-ship

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…

Compare Tool

Select up to 3 products