Protein Labeling & Detection
Benchmark BenchPress 2024 - Promos & Lab Favorites
Shakers, Incubators, Centrifuges, Balances, Rotators,
Vortexers, Dry Baths, Rockers and MORE!
Download the promotional brochure below learn more.
Benchmark BenchPress 2024 Promotional Brochure
Offers expire July 31, 2024
-
Consists of piston-type Teflon® pestle with stainless steel shaft and replaceable grinding vessel of borosilicate glass Eliminates ground glass from homogenate; Teflon minimizes heat generated in use Completely autoclavable Precisely controlled grinding clearance Pestles and vessels…
-
Ideal for Pressure Transmitters, Pumps, Gauges, Manifolds & More Creates a pocket of warmth to protect devices against extreme cold For use in all weather, sub-freezing environments Universal sizes for a wide range of objects Plug-and-play with extra-long 16 ft (5 m) power cord …
-
Disposable Polypropylene, RNase-Free Pellet Pestles
DWK Life Sciences (Kimble)Re-suspend protein and DNA pellets or grind soft tissues in micro centrifuge tubes Pestles can be hand operated or motor driven Autoclavable types available Ideal for cell and tissue culture preparation Choose the best pellet pestle for your applications RNase-, DNase- and Pyrogen-free …
-
The grinding vessel, a round bottom tube with 2 mm wall, has grinding chamber made of precision bore tubing and top reservoir with pouring spout, to accommodate displaced fluid. Unground walls are completely transparent. Pestle is rounded to conform to bottom of grinding chamber and is either…
-
Perfect Grind for the Perfect Pre-Roll! Designed to optimize grinding and extraction, the Revolution 2.0 commercial cannabis grinder delivers a consistent, homogenous grind, optimal for evenly packed rolls, extractions and higher potency of the product. The Revolution 2.0 employs a low heat,…
-
OptiChem® Heater Block Adapter
ChemglassFits all 135mm diameter hot plate stirrers Great visibility of the reaction Excellent heat distribution User safety: PTFE shield prevents potential burns and provides a safe contact area Aluminum construction provides excellent heat transfer and does not interfere with magnetic field …
-
Labworldsoft 6 Visc software
IKA WorksLabworldsoft 6 Visc software enables the automation of laboratory processes by connecting ROTAVISC viscometers to other devices, such as a thermostat, through a PC. Measurement processes and parameters can thus be easily recorded for analysis and documentation. In addition, users can e.g. monitor…
-
These PYREX® tissue grinders are designed to handle both initial grinding and final homogenization in the same sequence of operations. The lower conical section is intended primarily for the initial grinding. To assist in this work the clearance between mortar and pestle can be adjusted at will…
-
High Temp Premium DSC
Mettler ToledoHigh Temp Premium DSC with Sample Robot Premium air cooled DSC with sample robot. This DSC uses a ceramic sensor with 56 thermocouples guaranteeing outstanding resolution and sensitivity. High Temp Premium DSC with Sample Robot (Intracooled) Premium automated DSC with intracooler option…
-
Hot Stage Microscopy System HS82
Mettler ToledoThe HS82 hot-stage is the ideal solution where temperature of very small samples has to be regulated in a limited space while being observed. Mettler products are intended for sale/shipment within the US only. International customers should contact their local Mettler distributor to place…
-
Potter-Elvehjem Tissue Grinder With PTFE Pestle
DWK Life Sciences (Kimble)Similar to 3432N40 series, but with PTFE pestle and an unground glass tube Ideal for soft tissues Clearance between pestles and tubes is .004 to .006 inches* Pestle can be motor driven (see Thomas number 3411E25 for Drive Unit) Available in working capacities of 0.5, 1, 3, 5, 8,…
-
FGDI Drum Insulator
BriskHeatProduct Highlights Compliments any 55 gallon (208 liter) drum heater Full-coverage Reduces heat loss Specifications Silicone impregnated cloth facing and liner 1" (25mm) fiberglass insulation Closure: Hook and loop fastener like VELCRO® 500°F…
-
1 ml Tissue Grinder, Tapered, Gnd
DWK Life Sciences (Wheaton)These tapered tissue grinders have an improved design, which incorporates a longer tapered surface on both the mortar and pestle. The conical surface allows initial size reduction followed by passage through the cylindrical section for the final homogenization step. Grinding efficiency is improved,…
-
Product Highlights Suitable for a large range of surfaces like tanks, hoppers, conveyors, silos, etc. SRL Series: Ideal for metal surfaces Exceptional durability and longevity Patented grounded heating element for your safety meets NEC 427.23 Optional high-limit thermostat to…
-
-
Digital Dual Control Block Heater
Techne (Cole-Parmer)Two blocks with independent temperature control 130°C or 200°C maximum temperature Digital setting and display Uniform and stable temperatures Innovative design accommodating 2 blocks with independent temperature control allowing them to be set at different temperatures. The two…
-
SBH130 Analogue 2 Block Heater
Techne (Cole-Parmer)Analogue control Economical price 130°C maximum temperature Hot warning light to warn that the blocks are too hot to touch Uniform and stable temperatures Robust construction with simple analogue setting of temperature. The 'Hot' warning light will flash whenever the block…
-
Product Highlights Built for heating in extreme cold conditions down to: -40°F (-40°C) Durable industrial grade 60% more wattage than typical 5w/ft rated self- regulating heating cable Ideal for freeze protection and thawing: metal or plastic pipes and valves. Can also be…
-
These PYREX® tissue grinders (homogenizers) are recommended for soft tissues found in the liver and brain. They are designed to handle both initial grinding and final homogenization in the same sequence of operations. Mortar is not ground and the pestle contact surface is Polytetrafluorethylene…
-
Master-Mite® Heat Gun
Master ApplianceContinuous-duty Bench-top Heating System Complete system comes standard with 650°F/343°C heating element, adjustable stand and heat shrink attachment Quiet-running shaded pole motor, eliminates noisy production areas 3…
-
Grinds materials, by both impact and abrasion, that other grinders cannot Easy-to-use Very rapid grinding action Consistent particle size Air swept for easier cleaning and less thermal degradation USDA approved for NIR sample preparation Mill is designed for the rapid grinding of soft to…
-
HOOK™ (5/6) TAMRA-SE (Rhodamine) Labeling Kit
G-Biosciences(5/6) TAMRA-SE (5-(and -6)-Carboxytetramethylrhodamine succinimidyl ester, mixed isomers) is based on tetramethylrhodamine, one of the most common fluorophores used in the labeling of peptides, proteins, nucleic acids and nucleotides. (5/6) TAMRA absorbs green visible light at 546nm and emits an…
-
Used to control THERMOWELL heating mantles or other resistive heating circuits (hot plates, heat tapes, water baths, etc). Available in solid-state or proportional on/off models. All models are fused (without circuit breakers). Calibrated in terms of percent power level from 5 to 90% (i.e. when…
-
Thomas Pestle Tissue Grinder Assemblies with Serrated Pestles
labForce® (powered by Thomas Scientific)Consists of piston-type Teflon® pestle with stainless steel shaft and replaceable grinding vessel of borosilicate glass Eliminates ground glass from homogenate; Teflon minimizes heat generated in use Completely autoclavable Precisely controlled grinding clearance Pestles and vessels…
-
The Humboldt, Enclosed Model, Riffle-type Sample Splitter supports the following standards: ASTM C702, ASTM D410, ASTM D3013, ASTM D3176, ASTM D3180, AASHTO T248 Humboldt, enclosed model with drawer pans, Riffle-type sample splitter can be used to divide or halve dry materials such as cement,…
-
Master Heat Guns
Master ApplianceProfessional Quality, Heavy-duty, Multiple Use Heat Guns High temperature and power ratings: up to 1000°F/540°C at 1740 watts High air flow rating: 23 CFM at 3000 FPM gets the job done fast Powerful high speed universal motor Sturdy die cast aluminum housing …
-
These motor-driven PYREX® tissue grinders (homogenizers) are used in preparing small samples for pathological and biochemical studies. The clearance between the ground tube and pestle is approximately 0.15mm. The parts are ground to a medium grind to insure adequate abrasive qualities, yet…
-
Thermowell heating mantle
MilliporeSigmaEconomical and dependable. These mantles have a ceramic heat cavity (resistance wire completely embedded), a grounded metal housing for safer operation, a low profile that permits magnetic stirring, and can be operated at up to 550 C. May be used as an air or sand bath. All models have a 36 in.,…
-
Tissue Press
BiospecSimple operation Large capacity Threaded piston minces 10 to 50 grams of non-fibrous tissue. As the piston crank is turned, tissue is extruded through a sieve screen at the bottom. Clean up is simple with non-abrasive detergent and water. Includes three sieve screens with pore diameters…
-
This electrically insulated 25 gauge nichrome wire can be wound closed or open spaced. Max.temp 594 degreeC. The wire is approx. 1mm in diameter and has a resistivity of 2.1ohms/foot at 20 degree C; maximum ampere rating in open air at 594 degreeC is 3.7amps. The amperes are derated when enclosed…
-
Duall Tissue Grinder With PTFE Pestle
DWK Life Sciences (Kimble)Similar to 3432N01 series, but with PTFE pestle and an unground glass tube Ideal for soft tissue such as brain or liver Clearance between pestles and tubes is .004 to .006 inches* Pestle can be motor driven (see Thomas number 3411E25 for Drive Unit). Available in working…
-
AgileGrinder™ Portable Tissue Grinder
ACTGene, Inc.Feature Highlights: Three choices: ACT-AG12000 (Fixed Speed 12,000rpm), ACT-AG1500 (Fixed Speed 1,500rpm), and ACT-AG3080 (Adjustable Speed 3,000-8,000rpm) Motor driven Rechargeable battery keeps working for 10 hours Ideal for re-suspending pellets or disrupting soft tissue in…