TLC Plates & Sheets, TLC Plates, Plates
-
HPTLC SILICA GEL 60 NH2F254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaOur NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative…
-
TLC Kieselguhr F254
MilliporeSigmaPrecoated Kieselguhr or mixed Silica gel/Kieselguhr plates are only of small importance nowadays. Kieselguhr layers are used like cellulose layers for the TLC separation of polar and moderately polar substances. Polyamide, on the other hand , is used for the separation of flavonoids and other…
-
Silica Gel GHLF UNIPLATES
Miles Scientific (Analtech)These plates are 100% H20 resistant and are compatible with aqueous developing solvents. They are less rugged than the plates with organic binder but still provide improved handling and sample application compared to Silica Gel G UNIPLATES and are tough enough to write on with a soft pencil, if…
-
Nano-DURASIL Unmodified HPTLC Silica Layers
MACHEREY-NAGELFeatures Nano silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å, specific pore volume 0.75 mL/g, particle size 2–10 µm Indicator: manganese activated zinc silicate with green fluorescence for short-wave UV (254 nm) Hard, water-resistant and wettable…
-
TLC Aluminium oxide 60 F254, basic
MilliporeSigmaAluminiumoxide plates are used to analyze basic and neutral compounds at different pH levels. Depending on the pH range in question, professionals can choose between two kinds of aluminum oxide plates. Under aqueous conditions, basic aluminum oxide plates are best for separating basic compounds,…
-
TLC SILICA GEL 60 RP-18 F254S 25 GLASS PLATES 20 X 20 CM
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Milliporeare well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
Reversed Phase Octadecyl Silanized Silica Gel UNIPLATES
Miles Scientific (Analtech)These reversed phase TLC plates have been manufactured to be greater than 50% and less than 100% silanized. Because of this they are hydrophobic, but wettable. Features: 14% carbon content Acid stable (UV254) fluorescent indicator Glass backing 250um coating thickness 25…
-
TLC SILICA GEL 60 100 GLASS PLATES 2.5 X 7.5 CM
MilliporeSigmaEMDMilliporeclassical silica TLC plates are based on a combination of proven EMD Milliporesilica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
Baker-flex® Coated TLC Cellulose Sheets
Avantor - J.T.Baker®Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped The silica gel and aluminum oxide sheets have coating approximately 200 microns…
-
Silica Gel F TLC Plates
Miles Scientific (Analtech)Analtech’s flexible backed TLC plates offer the same exacting specifications as with the classic glass backed plates assuring batch-to-batch uniformity. Quality is controlled at each step in the manufacturing process — from incoming raw materials to outgoing packaging. Lighter…
-
TLC Silica gel 60
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
TLC Silica Gel 60 RP-18 F254s
MilliporeSigmaRP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. RP-modified silica layers from EMD Millipore are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous…
-
RP-18 W/UV254 Octadecyl-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g particle size 2–10 μm for preparative plates (1 mm thickness of layer) standard silica 60 particle size 5–17 µm pH stability…
-
HPTLC SILICA GEL 60 DIOL F254S 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaOur NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative…
-
Cellulose plates (TLC and HPTLC)
MilliporeSigmaFor analysis of polar substances The organic sorbent cellulose is particularly suitable for the separation of hydrophilic substances by partition chromatography. EMD Millipore cellulose plates include classical TLC grade or HPTLC plates for demanding high-performance separations: TLC…
-
TLC Cellulose
MilliporeSigmaPlates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. EMD…
-
Rectangular Developing Tank
General Glass BlowingBeveled inside and outside to remove any sharp edges Raised ridge midway on the inside ends and bottom for developing two 20 x 20 cm plates or the equivalent Inside dimensions: 27 x 7 x 26 cm Supplied with flat glass lid, 30 x 10 x 3 cm Molded glass block of clear glass with…
-
TLC Silica Gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
HPTLC silica gel 60
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
TLC Plate Storage Rack
General Glass BlowingStore TLC plates without damaging delicate media Holds up to 10, 20 x 20 cm plates or equivalent number of narrower plates Racked plates may be air or oven dried Can be used with plates in either vertical or horizontal position Racks are also used for storage of dried layers…
-
TLC Silica gel 60 F254
MilliporeSigmaClassic silica TLC plates are based on a combination of proven EMD Millipore silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
-
Fibrous cellulose impregnated with polyethyleneimine available as POLYGRAM® polyester sheets with or without fluorescent indicator Recommended application: analysis of nucleic acids, and of mutagenic substances with the 32P postlabelling procedure
-
HPTLC Silica Gel 60 F254
MilliporeSigmaHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. EMD Millipore’s HPTLC silica plates work three times faster than conventional TLC plates – and they’re more sensitive. The particle sizes range in HPTLC is between 4-8µm, which creates a smoother…
-
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. EMD Milliporeconcentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the…
-
Labels applied to all 4 sides of the plate. No sequence number duplicates. Exceptional print quality and resolution. Resistant to commonly used laboratory reagents. Resistant to temperature ranges of -80ºC to +52ºC. See Product Details below for bar code label specifications. Microplate…
-
10 cm Latch-Lid Chromatotank
General Glass BlowingRequires less solvent to maintain equilibrium Gives excellent retention of solvent saturated chamber Holds two 10 x 10 cm plates The smaller cubic inch chamber allows for a faster and more uniform solvent-saturated atmosphere. Single molded tank has a flat ground top, beveled for…
-
TLC Silica gel 60 F254 GLP
MilliporeSigmaThese plates feature individual laser coding for GLP applications. Designed for GLP applications, the tops of each of these plates bear an item, batch, and individual plate number. As a result, lab professionals can easily record and archive every plate they use. Based on proven EMD Millipore…
-
Features Silica 60, specific surface (BET) ~ 500 m2/g, mean pore size 60 Å specific pore volume 0.75 mL/g, particle size 5–17 µm available as glass plates with or without fluorescent indicator also available as ALUGRAM® Xtra aluminium sheets Excellent…
-
Nano-SIL CN Cyano-Modified HPTLC Silica Layers
MACHEREY-NAGELFeatures Base material: Nano silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å specific pore volume 0.75 mL/g particle size 2–10 μm pH stability 2–8 Indicator: acid-resistant product with a pale blue fluorescence for short-wave UV…
-
HPTLC CELLULOSE F 25 GLASS PLATES 10 X 10 CM
MilliporeSigmaCellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid…
-
Prepared by hydrolysis of high purity cellulose with HCl mean degree of polymerization 40–200 Available as glass plates and POLYGRAM® polyester sheets Recommended application: carboxylic acids, lower alcohols, urea and purine derivatives