SPE Columns, Columns, NEW! Life Science

Compare Tool

Select up to 3 products

1 - 32 of 158
Sort
View
Show
  • quick-ship

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • Retention Mechanism: Reversed-phaseSample Matrix Compatibility: Aqueous solutions (biological fluids, water) •Polymerically bonded, octadecyl (18 %C), endcapped •Higher 18 %C loading for increased binding capacities and higher recoveries •The least selective phase: retains most organic analytes…

  • Solid phase extraction apparatus uses glass vials or tubes for sample collection and concentration. Some sorbents require large desorption volume than small SPE cartridges in such case SPE tubes were used. The barrels are compatible with most vacuum-manifold devices and allow accurate loading of…

  • Agilent Technologies

    Ideal solid phase extraction for melamine analysis Ensures fast, reliable extraction of basic and cationic compounds Resistant to a wide variety of solvents Stable for pH ranges 0 - 14 Water-wettable Agilent's mixed-mode SampliQ SCX polymeric resin is a…

  • Avantor - J.T.Baker®

    Adapter (8330D64) 10 ea. Adaptors for 15, 75-ml Reservoirs & 1,3,6 m 1 'Baker' spe™ Columns

  • Retention Mechanism: Normal phaseSample Matrix Compatibility: Organic solvents, oils, and lipids •Unbonded acid washed silica sorbent ideal for normal phase SPE and other modified flash techniques •Often used to separate or remove structurally similar molecules through successive elutions with…

  • quick-ship

    MACHEREY-NAGEL

    Strong quat. ammonium modified polymeric anion exchanger for SPE Features Base material spherical PS/DVB copolymer, pore size 55–65 Å, particle sizes 45 µm or 85 µm (standard) very large specific surface 850 m2/g, pore volume 1.4 cm3/g, pH stability 1–14 …

  • MilliporeSigma

    Synonyms: SPE Reservoir

  • MACHEREY-NAGEL

    Hydrophilic-lipophilic balanced N-vinylpyrrolidone-divinylbenzene resin for SPE Features Hydrophilic-lipophilic balanced N-vinylpyrrolidone-divinylbenzene copolymer pH stability 1–14 Spherical particles 30 μm or 60 μm (standard) Pore size 65 Å Specific surface…

  • MACHEREY-NAGEL

    Kieselguhr phase for liquid-liquid extraction Features Base material coarse-grained kieselguhr (also known as diatomaceous earth, hydromatrix, celite) large pore size, high pore volume, constantly high batch-to-batch quality pH working range 1–13 Application: …

  • MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • quick-ship

    MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • MilliporeSigma

    Dispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…

  • MACHEREY-NAGEL

    Polystyrene-divinylbenzene adsorbent resin for SPE Features Highly porous polystyrene-divinylbenzene copolymer specific surface 1200 m2/g, particle size 50–100 μm very high binding capacity, up to 30 % of adsorbent weight (for comparison: silica adsorbents about 3 %) …

  • MACHEREY-NAGEL

    Ammonium – sulfonic acid modified silica phase for SPE Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g zwitterionic polar phase with ammonium – sulfonic acid modification, carbon content 7 %, pH stability 2-8 Polar…

  • Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…

  • MilliporeSigma

    Dispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…

  • Dispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…

  • Polar sorbent, used primarily to adsorb analytes from non polar solvents like hydrocarbons, chloro- or flouro-substituted hydrocarbons or less polar esters and ethers.

  • Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC

  • Empty SPE Tubes allow you to pack your own SPE cartridges Synonyms: pk 16, Empty Fritted 60-ml SPE Tubes

  • Retention Mechanism: Normal phase or Anion-exchangeSample Matrix Compatibility: Organic or aqueous solutions •Polymerically bonded, aminopropyl phase that is very polar in nature (hydrogen bonding) allowing for both normal phase and ion exchange applications •A weak anion exchanger with a pKa of…

  • MilliporeSigma

    Solid phase extraction apparatus uses glass vials or tubes for sample collection and concentration. Some sorbents require large desorption volume than small SPE cartridges in such case SPE tubes were used. Synonyms: SPE Reservoir Application: Empty SPE Tube (no frits) was coupled with…

  • With Speedisk columns, you can choose the column that works best with your sample size and performance requirements. Patented laminar configuration: reduces run time, increases capacity, eliminates filtration and evaporation steps Columns fit into all popular processors and racks …

  • MACHEREY-NAGEL

    Cyanopropyl modified silica phase for SPE Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 cyanopropyl phase, carbon content 5.5 %, polar to mid-polar In addition to weak hydrophobic interactions…

  • MACHEREY-NAGEL

    Propylcarboxylic acid modified silica cation exchanger for SPE Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 propylcarboxylic acid modified silica, weakly acidic cation exchanger (WCX) Recommended…

  • quick-ship

    Applied Separations

    Mini Spe-ed cartridges contain the wide variety of sorbents found in standard Spe-ed cartridges. The Mini Spe-ed configuration (similar to Sep-PakTM) can be easily used in manual syringe operations or on a vacuum manifold. Mini Spe-ed cartridges have a 1.0mL volume. For silica gel, this is…

  • Empty SPE Tubes allow you to pack your own SPE cartridges Synonyms: pk 20, Empty Fritted 20-ml SPE Tubes

  • MACHEREY-NAGEL

    Polymer-based SPE phases for RP and ion chromatography Features Base material: high purity polystyrene-divinylbenzene copolymers (PS/DVB), pore size 100 Å, particle size 100 µm very low degree of swelling, thus very well suited for chromatography reliable function…

  • Nonpolar SPE columns for acidic, neutral, and basic analyte extraction High surface area and capacity ensure highly reliable retention characteristics No secondary interactions from silanol groups for accurate results Higher sample loading due to high surface area Recover clean…

Compare Tool

Select up to 3 products