Agilent Technologies

Efficient LC Solutions that deliver the fast, reproducible results you need


  • Agilent Technologies

    Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable Agilent Technologies…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…

  • Agilent Technologies

    (50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…

  • Agilent Technologies

    Polyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Nitroterephthalic acid modified polyethylene glycol High polarity Temperature…

  • Agilent Technologies

    Exceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…

  • Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • Agilent Technologies

    Least “polar” Alumina phase Aluminum oxide deactivated with KCl Good choice for light hydrocarbon analysis Good resolution of propadiene and butadiene from ethylene and propylene streams Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT,…

  • Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • Agilent Technologies

    Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35,…

  • Agilent Technologies

    Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to…

  • Agilent Technologies

    (35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…

  • quick-ship

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…

  • Agilent Technologies

    Bonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…

  • Agilent Technologies

    30% heptakis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-β -cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization New stationary phase for improved resolution of many chiral separations Suitable for many chiral γ -lactones and terpenes Similar…

  • Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …

  • Agilent Technologies

    10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked,…

  • Agilent Technologies

    Most “polar” Alumina phase Aluminum oxide with proprietary deactivation Excellent general use column for light hydrocarbon analysis: C1 to C8 hydrocarbon isomers Separates C1-C4 saturated and unsaturated hydrocarbons Best for resolving cyclopropane from propylene …

  • Agilent Technologies

    Agilent J&W GS-CarbonPLOT uses a high stability, carbon-layer stationary phase to deliver unique selectivity for inorganic and organic gases. The column features an extended temperature limit to 360 °C. The retention stability of GS-CarbonPLOT is not affected by water, and the column is…

  • Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …

  • Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • Agilent Technologies

    Base deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …

  • Agilent Technologies

    (50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases:…

  • Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …