Molybdate CHEMets Kit, Range: 20-200 ppm
CHEMetricsMolybdate is used throughout the industrial water treatment and power generation industries as a corrosion inhibitor in both open- and closed-loop cooling water systems. In solution, molybdate anions complex with oxidized iron to form a protective film of molybdate and ferric-oxide. Molybdate is…
-
Method: colorimetric with test strips and reagents 10 - 25 - 50 - 100 mg/l Ca 2+ MQuant™ UN Number: UN3316 Storage class: 5.1B Oxidizing hazardous materials Storage: Store at +2°C to +8°C. Hazard: Corrosive The calcium test is suitable for rapid…
-
Color of Water Sets
LovibondA method for measuring the color of potable water in terms of an easily reproducible color standard is essential to water engineers responsible for the distribution of supplies for public consumption. Color determinations are useful for detecting any irregular contamination of the supply due…
-
Reagents Chlorine is the most widely used disinfectant for drinking water and is also important for sanitizing swimming pools, cooling towers, other industrial equipment and treatment of wastewater. Its measurement and control are vital for both safety and economic reasons. Many Hach chlorine…
-
Hardness is a measure of the mineral content of water. Calcium and magnesium are the most common minerals that contribute to hardness. Hard water causes scaling in boilers and other industrial equipment, and diminishes the effectiveness of soaps and detergents. The EGTA Method (Calcium) …
-
Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-60 & 60-600 ppm MDL: 10 ppm Method: Direct Nesslerization …
-
Because of its strong oxidizing properties, chlorine is an excellent biocide used to treat potable waters, municipal wastes, and swimming pools. When used to treat potable water, chlorine helps alleviate the adverse effects of iron, manganese, ammonia, and sulfide. The Maximum Residual Disinfectant…
-
-
Sulfide Vacu-vials® Kits
CHEMetricsSulfides are naturally present in ground waters as a result of leaching from sulfur-containing mineral deposits. Surface waters do not usually contain high sulfide concentrations. Sulfides result from the decomposition of organic matter, from bacterial sulfate reduction under anaerobic conditions…
-
-
Phosphate CHEMets® Kits
CHEMetricsPhosphorus occurs naturally in rock formations in the earth's crust, usually as phosphate. High phosphate concentrations in surface waters may indicate fertilizer runoff, domestic waste discharge, or the presence of industrial effluents or detergents. Although phosphates from these sources are…
-
Ammonia HBA Test Kit
CHEMetricsLow-level ammonia nitrogen may be naturally present in water as a result of the biological decay of plant and animal matter. Higher concentrations in surface waters can indicate contamination from waste treatment facilities, raw sewage, industrial effluents (particularly from petroleum refineries),…
-
-
-
Sulfite (free) Titrets® Titration Cells
CHEMetricsSulfite is not usually present in surface waters. If sulfite is discharged in effluents or from domestic wastewaters, it readily oxidizes to form sulfate. Sodium sulfite is the most common form of sulfite and is an excellent reducing agent with applications as an oxygen scavenger. Sulfite…
-
Detergents CHEMets Kit, Range: 0-3 ppm
CHEMetricsDetergents can be introduced into the water supply by industry, soap manufacturers, and private households. Environmental analysts often include a determination of anionic detergents when assessing surface water pollution. The Methylene Blue Method References: USEPA Methods for…
-
-
-
ColorQ® 2x PRO 7-PLUS Kit
LaMotteThe waterproof, Bluetooth ® ColorQ ® 2x PRO 7-PLUS Kit handheld professional pool photometer directly measures the seven primary tests of Free Chlorine (DPD), Total Chlorine (DPD), Bromine (DPD), pH, Alkalinity, Calcium Hardness, and Cyanuric Acid directly on a digital display. The…
-
-
Kit Contains: 100 Chlorine DPD #1 Tablets 50 Phenol Red Tablets 3 Test Tubes, 2.5, 5, 10 mL, plastic w/ caps 1 Chlorine/Bromine Octa-Slide 2 Bar 1 Phenol Red Octa-Slide 2 Bar, pH 6.8-8.2 1 Octa-Slide 2 Viewer
-
BrewLab® Basic
LaMotteTest for 7 Essential Factors Chloride Sulfate Alkalinity Total Hardness Calcium Hardness Magnesium Hardness Sodium
-
-
-
UN Number: UN3316
-
Chloride Test Kit
LaMotteThis kit tests for Chloride in fresh water samples using the Direct Reading Titrator method. Applications: Environmental Education, Aquarium and Fish Farming
-
Cyanide Test Kit
LaMotteOctet Comparator For determining trace levels of free cyanide in water Octet comparator has color standards representing 0.00, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35 and 0.40 ppm Free CN - Sufficient for 50 tests
-
-
Phosphonate Test Kit
LaMotte7625 CAS Dropper Pipet Sufficient for 50 tests at 20 ppm 1 drop = 1.25 ppm HEDP 1 drop = 1.4 ppm PBTC Chromazurol S method may be used for Dequest, Bayhibit, Belcor 575 and Belsperse 161 phosphonates. Indicator changes from yellow to pink at the pH ideal for the reaction, then…
-
Hydrazine VACUettes Kit, Range: 0-12.5 ppm
CHEMetricsHydrazine is a powerful reducing agent that is used in various chemical processes and in boiler water as an oxygen scavenger. To control corrosion, residual hydrazine typically is maintained in the 0.05 to 0.1 mg/L range. Higher levels may be used to guard against corrosion when the boiler is out…