Syringes, Hamilton, Bottles, Non-Sterile
-
Purge & Trap Syringes
HamiltonDesigned for the analysis of drinking water samples according to EPA purge and trap concentration techniques Easy-to-remove syringe plunger for loading water samples into syringe barrel. Internal standard or surrogate sample can be added directly through twist valve.
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Teflon ® PTFE tipped plungers Replaceable barrels, plungers and tips Cemented or removable needles For use with liquids or gases. Features a precision-machined Teflon plunger tip which, when wetted, forms an interference fit with the inner diameter of the glass barrel to achieve the seal…
-
-
Removable needles Length: 1.71” HP point style See 8928C31 series for replacement needles.
-
Length: 1.71 HP point style See 8928C31 series for replacement needles for removable needle syringes.
-
Removable needles Length: 2.756” Point style: 3 Replacement needles available on special order.
-
Multi-Channel Syringe Pipettes
HamiltonQuickly transfer 4, 6, 8 or 12 samples from microwell plates to sequencing gels, nylon membranes or another microwell plate Adjustable volume stops Minimize sample order error GASTIGHT™ Syringes provide accuracy of greater than 99%. Adjustable stops allow for fast,…
-
Removable Needle
HamiltonSmall Hub Removable (RN) needles can be used with Removable Needle (RN) syringes that are 100 µL and smaller. Standard needle length is 2 in / 51 mm. Removable (RN) needles are available in convenient six packs. Custom lengths and point styles are available.
-
Removable needles Length: 1.71” HP point style See 8928C19 series for replacement needle kits.
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Cemented needles on 8928B58-64 Removable needles on 8928B67 Length: 2” Point style: 2 See 8928C40 for needle for 8928B67.
-
1000 Series Gastight Syringes
HamiltonTeflon ® PTFE tipped plungers Replaceable barrels, plungers and tips mL sizes For use with liquids or gases. Features a precision-machined Teflon plunger tip which, when wetted, forms an interference fit with the inner diameter of the glass barrel, achieving the seal required for…
-
Digital Syringes
HamiltonThe most accurate manually operated syringes available Consistent plunger position LCD NIST Traceable Ergonomically designed syringes have a fine adjustment thumbwheel for easy volume control. Plunger drag adjustment optimizes the rate of plunger movement to the…
-
Syringes
HamiltonThe Hamilton 700 series microliter syringe offers SST and borosilicate glass fluid path. This 10 uL syringe can be used at a pressure rating of up to 2000 psig.
-
Bruker Varian 8100 and 8200 Syringes
HamiltonFor Varian 8034 Length: 2” Point style: 2 See 8928C40 for replacement needles. For Varian 8100/8200 Length: 1.99” Point style: 5 See 8928C47 for replacement needles.
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Syringes
HamiltonThe Hamilton 700 series 100 uL syringe is suitable for use with small removable needles. This syringe model offers SST and borosilicate glass fluid path. It can be used at a pressure rating of up to 2000 psig and temperature rating of up to 10 to 115 degree F.
-
600 Series Microliter Syringes
HamiltonHamilton's '600 Series' syringes are a rugged, durable, and long lasting half stroke version of Hamilton’s original 700 series syringes. They have a reinforced plunger which prevents plunger bending. Each plunger is individually fitted to the glass barrel and cannot be…
-
Syringes
HamiltonThe Hamilton gaslight syringe features ChemSeal (C, 1/4 Inch - 28) termination. This syringe model offers borosilicate glass, PTFE and PFA fluid path. It can be used at a temperature rating of up to 10 to 115 degree C.
-
Gauge: 25s Length: 1.97” Point style: 3 Syringes feature removable needles; Teflon ® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. 1800 Series has adjustable friction, which controls plunger resistance, and plunger stop helps prevent blow-out. …
-
Gastight syringes for injection of Gas and Liquid Samples. Removable Needle (RN), (point style 2) Autoclavable needles are 51 mm 22s gauge
-
Custom HAT NDL Syringes
HamiltonAvailable options: Custom Length: 0.375 to 12 in Point Style: 2, 3, or 4
-
Point styles 2 and 3 Standard 2” length Needles seat precisely to the zero graduation mark of the syringe. They are autoclavablewhen disassembled. They allow the use of different specification needles with the same barrel. The small ‘s’ next to the gauge number indicates…
-
Length: 2” Point style: 3 For use with Rheodyne, Valco™ VISF-2, Beckman®/Altex and SSI injection valves. Syringes are available with cemented or removable needles and feature Teflon® PTFE-tipped plungers. Barrel, plunger and plunger tip are replaceable. See…
-
The 1000 series syringe is a mid-volume Gastight syringe. Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined polymer plunger tip, often PTFE, which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe…
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Gastight Syringes For HP 7683/7673 GC Autosamplers…
-
GC On-Column Syringes
HamiltonRemovable needles Fused silica needle Length: 100 mm (8928C59: 115 mm); Point style: 3. Syringes 8928C65 to C68 and C77 to C83 are gas-tight.
-
Metal and Kel-F® hub 304 stainless steel needle Standard 2” length Use with Luer Tip and Luer Lock syringes sold without needle or for Luer adapters. Nickel-plated brass or Kel-F (CTFE) hubs fit both male and female Luer connectors.They allow quick change of needle and use…
-
700 Series Microliter Syringes
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. The stainless steel plunger is manufactured to fit the glass barrel with a tolerance less than three thousandths of a millimeter, resulting in unsurpassed syringe life. This series of syringes is ideal for dispensing volumes from…
-
Shimadzu AOC-9 Syringes
HamiltonHamilton offers a wide variety of syringes specifically designed for Shimadzu autosamplers that require 43 mm needle lengths as well as standard 51 mm lengths.