PerkinElmer GC Instrument Parts and Supplies
-
Gas Chromatography Connector
PerkinElmerThe PerkinElmer gas chromatography connector consists of a 9/16 Inch hex nipple and the 1/4 Inch MNPT thread provide a tight connection. Solid brass construction offers added strength and durability.
-
TurboMatrix Analytical Caps
PerkinElmerAll your consumable needs in one convenient kit, designed specifically for Industrial Hygiene using Thermal Desorption. Required for use on the TurboMatrix instrument during analysis (use with brass long-term storage caps).
-
The PerkinElmer UHP-ZA zero air generators produce a continuous stream of organic impurity free air from an external dry compressed air source and offer superior limits of detection over and above other modes of supply. Flow rates range from 1 L/min to 30 L/min.
-
-
CAPILLARY Quartz Liner for Split Operations, with Silanized Glass Wool, for Programmed-Temperature Split/Splitless Inlet System
-
Mix D for Method 624
PerkinElmerWe offer standard solutions to meet your environmental analysis requirements.
-
Fused-silica Adapters allow connection of fused-silica to unions, valve ports, and reducers.
-
Thermal Conductivity Detector (TCD) with Add-On Kit for PerkinElmer Clarus 500 GC, 120V
-
PerkinElmer UHP-ZA zero air generators produce a continuous stream of organic impurity free air from an external dry compressed air source and offer superior limits of detection over and above other modes of supply. Flow rates range from 1 L/min to 30 L/min.
-
Kit includes all necessary items to install the TCD into theinstrument: detector, heater, sensor, heater block, 1/6 in. gasline, and flow controller pneumatics. How it Works: Balanced carrier flow is maintained through the analytical andreference channels. The filaments are electrically heated…
-
Filter Disc
PerkinElmerThe PerkinElmer filter disc has a larger design and the PTFE construction offers more strength. This disc is compatible to use with PerkinElmer TurboMatrix thermal desorption instruments.
-
Cyclo Splitter Split Liner 4mm
PerkinElmerCyclo Splitter Split Liner 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length.
-
TCD/FID Series Operation Kit used to direct sample effluent from the TCD to the FID.
-
TheProgrammed Temperature Split/Splitless Injector Starter Kit includes the proper starter and/or replacement parts to keep your programmed temperature injector system operating at peak efficiency.
-
Heat Shield Seal Assembly & Window
PerkinElmerThe PerkinElmer seal assembly and window comes with a FPD detector and consists of a heat shield that protects the seal from extreme temperatures.
-
Description - Quantity 1/8"""" Tubing x 50 foot coil Copper Special Cleaning- 1 1/8"""" Compression Brass Tee Two Piece Ferrule Brass- 3 Tee 1/8"""" Com x 1/8"""" Comp x 1/4"""" fnpt Brass- 3 Adjustable Safety Relief Valve Brass 50 - 150 PSI- 3 1/4"""" fnpt x 1/8"""" Comp Fitting Brass- 3 1/8""""…
-
S-Swafer Splitter Kit for new Clarus GCs
PerkinElmerFeatures and benefits include: Allows you to tackle difficult or otherwise impossible separations, delivering richer sample information which was previously unattainable User-friendly design and user-defined oven position allow easy setup and configuration changes, without requiring service…
-
Purgeable Gases Mix for Methods 8260B/524.2
PerkinElmerWe offer standard solutions to meet your environmental analysis requirements.
-
-
Replacement External Retaining Nozzle Ring
PerkinElmerThe PerkinElmer external retaining nozzle ring comes with an FID detector and is mainly used in laboratory and manufacturing factories.
-
PSS Siltek Deactivated Split/Splitless Liner with Wool 2mm; 2mm I.D x 4.0mm O.D x 86.2mm length. Wool provides a large surface area to allow rapid vaporization of the sample and deliver a uniform vaporn cloud to the split point. The low mass of wool fiber promotes complete vaporization.
-
Replacement Plastic Plunger for Gauze Loading Device, Pkg.5
-
Glow Gas Chromatography Plug
PerkinElmerThe PerkinElmer glow gas chromatography plug comes inclusive of the auto igniting flame ionization detector and has a solid stainless steel construction.
-
LINER-CAP AS SPLTLS WOOL 4MM UNIV
PerkinElmerApplication - Universal liner for general purpose analyses, intermediate polarity. Wipes the sample from the tip of the needle for complete transfer Gives accurate and reproducible results Performs well in splitless mode Promotes vaporization of sample Minimizes mass discrimination Prevents…
-
Collector Head
PerkinElmerThe PerkinElmer collector head is designed to use with NPD detector in the gas chromatography technology.
-
Stainless Steel Back Ferrule, Size: 1/4in
PerkinElmerStainless Steel Back Ferrule, Size: 1/4in, Pkg 5
-
Bench Top Crimper without Jaws
PerkinElmerBench-top vial crimper without jaws. Requires jaws to work (sold separately).
-
Auto-Ignite Catalytic Reactor Accessory
PerkinElmerThe PerkinElmer auto-ignite catalytic reactor accessory features an auto-ignite mechanism that makes it easy to use for the user.
-
This glass liner is specifically designed to be used for Fuel in Oil analysis.
-
Polynuclear Aromatic Hydrocarbons for Method 625
PerkinElmerWe offer standard solutions to meet your environmental analysis requirements.
-
Hydrogen Regulator Replacement Kit
PerkinElmerThe PerkinElmer regulator replacement kit makes use of gas chromatography technology for the regulation and monitoring of hydrogen.
-