Counters

Compare Tool

Select up to 3 products

1 - 32 of 58
Sort
View
Show
  • The C-Chip disposable hemocytometer is used for manual cell counting. In research settings, it helps to determine cell concentration prior to cell passage, or to assess cell viability following drug treatment; cell counting solution is essential. Obtaining accurate cell counts can be critical when…

  • Diffcount™ III Compact keyboard with “soft-touch” keys Provides fast counts with much less fatigue All entries register with audible clicks With count correction All counting channels and total count are simultaneously displayed with larger digits on…

  • With a digital camera and high technology software, they can be linked to a PC via a USB connection. They count all colonies on a Petri dish in less than 1 second and provide a complete, fast, accurate and traceable reading of the result. High performance Count colonies of numerous…

  • Similar to 5971C10 Chamber, but for platelet count using phase microscope Without concavity beneath the rulings. No. 1 1/2 cover glass, 22 x 30 mm, should be used. Cover glass not furnished, see Thomas number 1208Q35.

  • Colony Counter

    Stuart (Cole-Parmer)

    Pressure sensitive counting Average count facility Bright white energy saving LED lighting With BioCote antimicrobial protection Audible count confirmation Choice of light or dark background Connectivity to printer or computer Touch pressure with felt tip marker on petri…

  • Modification of the Fuchs-Rosenthal counting chamber Designed for rapid, direct counts of eosinophil cells in peripheral blood for the assay of adrenal cortical hormone level in clinical experiments and for use in the administration of ACTH for the treatment of arthritis Chamber is 0.2 mm…

  • The 1 and 2 counting units have a range of 0 – 999 with a single reset knob. The 2 counter unit has removable tabs for top identification. The 5 and 8 counting units record up to 999. The last unit without a key on the right is the totalizing unit which records the total number of…

  • Hemacytometer

    LW Scientific

    Our hemacytometer is specially designed for counting erythrocytes and leukocytes. Double rulings are visible through a wide range of illumination. Neubauer rulings are 0.1mm below cover glass. The H-shaped moat offers two counting areas. Fused rhodium on glass provides distinct lines. High…

  • Hausser Hy-Lite Kit

    Hausser Scientific

    Includes Thomas number 5971C10 Counting Chamber with double improved Neubauer ruling, two 20 x 26 mm cover glasses and two Thomas diluting pipets, one for red and one for white cells

  • Four digit hand counter records to 9999. White numerals are on a black background for ease in reading. Thumb pressure on button produces an audible click.

  • Rectangular Cover Glass

    Hausser Scientific

    5972M10 cover glass is for use with double-ruled chambers. 5972M20 cover glass is for use with Speirs-Levy Eosinophil Chamber.

  • Hemacytometer Bright Line

    Hausser Scientific

    The Bright-Line Hemacytometer is molded from a single piece of thermal and shock-resistant glass. An H-shaped moat forms two counting areas, or plateaus. A "V" slash at the loading side of each plateau facilitates charing and reduces the possibility of overflow into the moat. Each plateau…

  • With two improved Neubauer rulings cut through the metalized surface of the counting area Ruling appears bright in contrast to fused-on, semitransparent metal layer V-shaped slit on the loading side of each counting area facilitates charging and minimizes overflow Chamber has…

  • Applications: Cell counts in cerebrospinal fluid (CSF), rare cells Blood analysis (Hematology): Blood cell counting Cell culture: Cell concentration measurement, Cell viability test Microbiology: Fungal spores counting Calculation The full grid on a hemocytometer…

  • Traditionally differential counters have been manual "gear and lever" machines, and many lab techs are accustomed to the feel of the levered keys. LW Scientific offers both 5-key and 8-key manual counters for those traditional techs to count Baso, Eosin, Myelo, Juven, Stab, Seg,…

  • eCount™ Handheld Colony Counter

    Heathrow Scientific

    The eCount is a simple to use colony counter for counting cells inmicrobiology applications or tissue culture. This unit combines a multifunctionelectronic counter with a Sharpie® pen for counting and markingto prevent missing or double-counting colonies in a Petri dish. US Patent No.…

  • Digital Hand Tally

    Compass Instruments

    Finger ring for comfortable fit Registers to 9999; also has zero reset knob

  • Multi-Position Hot Plate Stirrer

    Techne (Cole-Parmer)

    Three independently controlled stirring/heating positions Separate "Hot" warning lights for each plate Powerful magnets for strong magnetic coupling A space saving and economical unit with 3 independent heating/stirring positions in a footprint only 600 x 270mm. Easily accommodates 3…

  • The new and improved Digital Differential Counter uses modern technology and microprocessor-controlled electronics for accurate cell counts. The 8 alternating red and white buttons have a comfortable, ergonomic feel for positive and accurate finger positioning, and the 3-digit LCD windows display…

  • Counting Slide

    Thomas®

    Consists of a shallow glass cell, 17.9 mm diameter x 0.4 deep, provided with two charging channels, 2 mm wide x 5 mm long For counting smaller plankters, use 43X dry objectives of approximately 0.65 n.a. and 4 mm e.f. See C.M. Palmer and T.E. Maloney. American Society of Limnology and…

  • Legal Information BLAUBRAND is a registered trademark of Brand GmbH & Co. KG BRAND is a trademark of Brand GmbH & Co. KG

  • Will accept any size dish up to 150 mm in diameter Curved mirror with a 3x magnification Tilting round magnification mirror can be rotated to the angle of choice for viewing. Useful in visualizing the contents of 96 well micro titer plates for color changes.

  • Accurate Cell Counts in a Flash For years, the choice between manual and automated cell counting has been a difficult one. Manual cell counting, on the one hand, is accurate, but time-consuming and very userdependent. Automated cell counting, is much faster and less user-dependent, but the cost…

  • For obtaining counts automatically as percentage Wide steel base plate for desk or benchtop mounting Color-coded buttons All counters and totalizers register to 999 Quickly and accurately obtain differential blood cell, bone marrow, chamber and other laboratory counts. Locking totalizers…

  • Reichert,dark field counter with electronic register Similar to 3298A80 but with built-in electronic register that is operated by needle- point probe or push button counter Reset bar provides immediate zeroing of the five-digit counter Sparse colonies can be counted rapidly using…

  • EMS Sedgewick-Rafter Counting Cells

    Electron Microscopy Sciences

    Intended for use with standard or inverted compound microscopes at low magnifications. Intended for use with standard or inverted compound microscopes at low magnifications. Cat. #63509-02 features a millimeter square grid, providing the ability to extrapolate the number of zooplankton, thus…

  • Manual microscopic cell counting in a Fuchs-Rosenthal (FR) chamber has been the gold standard for quantification of leukocytes in cerebrospinal fluid (CSF). An excellent correlation between cell counts obtained with the C-Chip chamber and FR chamber was observed. ("Determination of leukocyte…

  • Scienceware® Replica-Plating Device

    Bel-Art - SP Scienceware

    Low-Cost, Accurate Method of Colony Replication Utilizes a locking ring which secures sterile velveteen squares onto a PVC cylinder for easy control of the plating device. To produce replicas, the Petri dish carrying microbial colonies is inverted and lowered onto the cloth surface, then…

  • Dark-Line Etched Hemacytometer

    Hausser Scientific

    The Dark-Line Hemacytometer is of one piece construction, ensuring long term durability and accuracy. An H-shaped moat forms two counting areas, or plateaus. A "V" slash at the loading side of each plateau facilitates charing and reduces the possibility of overflow into the moat. Each…

  • Scienceware® Colony Counter

    Bel-Art - SP Scienceware

    A cost effective and accurate way to count colonies of bacteria or other microorganisms grown on an agar plate. This hand-held, simple to operate device marks, counts, and gives an audible and visual alert each time a count is registered. The lightweight, pen-style design reduces the likelihood of…

  • Reichert, Dark Field Standard Colony Counter Provides even glare-free illumination of round or square Petri dishes Contrasted against the dark field background colonies are bright and readily distinguished from other structures in the agar A highly polished, annular reflector…

  • The Fuchs-Rosenthal Counter is one piece construction ensuring durability and accuracy, featuring a Fuchs-Rosenthal ruling on a single plateau. TheFuchs-Rosenthal Counting Chamber is used for Cerebro-Spinal Fluid cell counts. (Cell-Depth 0.2mm) Directions for Use Usage: Cell Counts in…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.