HP-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to 250°C Designed for the analysis of volatile fatty acids and phenols Replaces OV-351 Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 …
-
DB-210
Agilent Technologies(50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…
-
Dbht-Simd 5m, 0.53mm, 0.15um
Agilent Technologies100% Dimethylpolysiloxane “Boiling point” phase for high temperature simulated distillation Durable stainless steel tubing 430°C upper temperature limit Distillation range of C6 to C110 Low bleed - even at 430°C Bonded and cross-linked Solvent…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
PRP-1 Reversed Phase HPLC Columns
HamiltonPolymeric 100 Å columns for general reversed phase separations. pH stable from 1 to 13 Better sample recovery than silica-based columns (there are no silanol groups) Excellent durability (stable to any concentration of water or organic solvent) Five particle…
-
DB-Wax
Agilent TechnologiesPolyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …
-
DB-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to DB-1 Non-polar Very low bleed characteristics, ideal for GC/MS Improved acid performance compared to standard 100% Dimethylpolysiloxane columns Improved signal-to-noise ratio for better sensitivity and mass spectral integrity …
-
HP-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C…
-
HP-5
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Non-polar Excellent general purpose column …
-
DB-624
Agilent TechnologiesSpecifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…
-
HP-Plot Q
Agilent TechnologiesBonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…
-
Ultra 1 & Ultra 2
Agilent TechnologiesUltra 1: 100% Dimethylpolysiloxane Ultra 2: (5%-Phenyl)-methylpolysiloxane Non-polar Bonded and cross-linked Solvent rinsable HP-1 and HP-5 with tighter specifications for retention index and capacity factors Temperature range: -60° to 325°/350°C …
-
DB-1ht
Agilent Technologies100% Dimethylpolysiloxane Non-polar Specially processed for extended temperature limit of 400°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Bonded and cross-linked Solvent rinsable …
-
Cyclosil-B
Agilent Technologies30% heptakis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-β -cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization New stationary phase for improved resolution of many chiral separations Suitable for many chiral γ -lactones and terpenes Similar…
-
DB-1701
Agilent Technologies(14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170 Agilent Technologies products are intended for…
-
GS-Alumina KCl
Agilent TechnologiesLeast “polar” Alumina phase Aluminum oxide deactivated with KCl Good choice for light hydrocarbon analysis Good resolution of propadiene and butadiene from ethylene and propylene streams Similar Phases: CP-Al2O3/KCl PLOT, Rt-Alumina PLOT,…
-
Cyclodex-B
Agilent Technologies10.5% Beta-Cyclodextrin in DB-1701 Chiral separations without chiral specific derivatization Broad range of resolving potential Excellent peak shape Similar Phases: LIPODEX C, Rt-β DEXm, β -DEX 110, β -DEX 120 Because Cyclodex-B GC columns are not bonded or cross-linked,…
-
DB-5.625
Agilent TechnologiesEquivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…
-
CAM
Agilent TechnologiesBase deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …
-
DB-5 And DB-5ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …
-
HP-Ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …
-
DB-Tph 30m, 0.32mm, 0.25um
Agilent TechnologiesSpecifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable Agilent Technologies…
-
HP-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…
-
HP-Voc
Agilent Technologies• New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
GS-Gaspro
Agilent TechnologiesBonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
DB-ALC1 And DB-ALC2
Agilent TechnologiesMeets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …
-
DB-17ht
Agilent Technologies(50%-Phenyl)-methylpolysiloxane Midpolarity Extended upper temperature limit of 365°C High temperature, polyimide-coated, fused silica tubing Excellent peak shape and faster elution times for high boilers Improved resolution for triglycerides Ideal for…
-
DB-XLB
Agilent TechnologiesExceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…
-
HP-5ms
Agilent TechnologiesMeets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
DB-624
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…