SPE Columns, Columns, Equipment

Compare Tool

Select up to 3 products

1 - 32 of 158
Sort
View
Show
  • MACHEREY-NAGEL

    Special phase for SPE enrichment of acrylamide from water (DIN 38413-6) Features Base material: activated carbon, highly porous, spherical particles, specific surface >1000 m2/g Recommended application: Determination of acrylamide from water according to DIN 38413-6 Note:…

  • MACHEREY-NAGEL

    Polystyrene-divinylbenzene adsorbent resin for SPE Features Highly porous polystyrene-divinylbenzene copolymer specific surface 1200 m2/g, particle size 50–100 μm very high binding capacity, up to 30 % of adsorbent weight (for comparison: silica adsorbents about 3 %) …

  • MACHEREY-NAGEL

    Special products for determination of pesticides in food samples QuEChERS method and pre-mixes Within a few years after its development by Anastassiades et al. the QuEChERS method has gained a leading position for the determination of pesticide residues in food samples by GC-MS or LC-MS,…

  • Sep-Pak Alumina B Plus Long cartridges contain a highly active grade of alumina with a basic surface chemistry. The aluminum oxide surface provides an extremely polar surface for analyte retention and has properties of a Lewis acid. This normal phase sorbent is similar in use to silica; however, it…

  • Affinimip SPE is a selective solid phase extraction based upon molecularly printed polymers (MIP). It combines the advantages of Immune-affinity columns in terms of selectivity and a classic solid phase extraction (SPE) in terms of robustness and costs. This selectivity and robustness combines to…

  • Polar sorbent, used primarily to adsorb analytes from non polar solvents like hydrocarbons, chloro- or flouro-substituted hydrocarbons or less polar esters and ethers.

  • Solid phase extraction apparatus uses glass vials or tubes for sample collection and concentration. Some sorbents require large desorption volume than small SPE cartridges in such case SPE tubes were used. Application: Empty polypropylene SPE tube with PE frits was used in preparing…

  • Avantor - J.T.Baker®

  • Sep-Pak Accell Plus QMA Vac cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger…

  • MACHEREY-NAGEL

    Special silica phase for SPE of THC and derivatives acidic analytes from biological fluids (urine, blood ...) Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 special bifunctional modification – C8 /…

  • Avantor - J.T.Baker®

    Adapter (8330D64) 10 ea. Adaptors for 15, 75-ml Reservoirs & 1,3,6 m 1 'Baker' spe™ Columns

  • MACHEREY-NAGEL

    Special silica phase for determination of pesticides in food samples Features Base material silica, pore size 60 Å, particle size 45 μm, specific surface 500 m2/g, pH stability 2–8 Primary and Secondary Amine functions (PSA), 5 % C Removes polar compounds (e.g.,…

  • For individual packing of SPE columns with CHROMABOND® adsorbents.

  • Mixed-mode strong anion exchange columns for acidic analyte extraction High surface area and capacity ensure highly reliable retention characteristics No secondary interactions from silanol groups for accurate results Higher sample loading due to high surface area Recover clean…

  • Caplugs Evergreen®

    Choose from three different sizes of Surety® Columns for a wide range of capacities. Specifically designed for the use of removing fibrin and macro particles from serum to prevent line clogging. Columns have integral caps that fit directly onto sample cups. Columns may be used…

  • Retention Mechanism: Normal phase or Anion-exchangeSample Matrix Compatibility: Organic or aqueous solutions •Polymerically bonded, aminopropyl phase that is very polar in nature (hydrogen bonding) allowing for both normal phase and ion exchange applications •A weak anion exchanger with a pKa of…

  • MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • Supelclean(TM) LC-Si SPE Tube is used to adsorb moderately polar to polar compounds from nonaqueous samples. Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC

  • MACHEREY-NAGEL

    Polar, bifunctionally modified polystyrene-divinylbenzene copolymer Features Polar modified polystyrene-divinylbenzene copolymer with a weak anion exchanger, specific surface 650–700 m2/g, particle size 80 µm, pore size 50 Å, pH stability 1–14 The Easy…

  • Supelclean(TM) LC-Si SPE Tube is used to adsorb moderately polar to polar compounds from nonaqueous samples. Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC

  • MACHEREY-NAGEL

    Propylcarboxylic acid modified silica cation exchanger for SPE Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2–8 propylcarboxylic acid modified silica, weakly acidic cation exchanger (WCX) Recommended…

  • Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC

  • Empore membrane SPE technology comprises of SPE particles tightly enmeshed within a network of inert PTFE fibrils (90% SPE particles : 10% PTFE, by weight). The SPE-membrane fabrication process results in a highly dense and uniform extraction medium that offers distinct advantages over traditional…

  • Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride…

  • Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids…

  • Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids…

  • MACHEREY-NAGEL

    Special phase for drying organic samples Features Anhydrous high-purity sodium sulfate which forms Glauber’s salt with traces of water – For removal of larger quantities of water several cartridges can be combined in series. Recommended application: removal of traces of…

  • MACHEREY-NAGEL

    Kieselguhr phase for liquid-liquid extraction Features Base material coarse-grained kieselguhr (also known as diatomaceous earth, hydromatrix, celite) large pore size, high pore volume, constantly high batch-to-batch quality pH working range 1–13 Application: …

  • The 3 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is…

  • Reversed Phase (Non-Polar) 24% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60 Angstrom to reduce pressure drop and increase flow reproducibility Agilent’s…

  • quick-ship

    MACHEREY-NAGEL

    Features More than 50 different sationary phases available e.g., silica gel based: unmodified, C8, C18, NH2, CN; Polyermic material: HR-X, HLB, PA; mixed-mode, special combinations, aluminum oxide, kieselguhr (XTR) etc. NP, RP, ion exchanger and for special applications Different…

  • With Speedisk columns, you can choose the column that works best with your sample size and performance requirements. Patented laminar configuration: reduces run time, increases capacity, eliminates filtration and evaporation steps Columns fit into all popular processors and racks …

Compare Tool

Select up to 3 products