General Chromatography Columns

Compare Tool

Select up to 3 products

HomeAll Products

Thermo Scientific Columns General Chromatography Columns

1 - 32 of 39
Sort
View
Show

  • Click-On Inline Filters

    Thermo Scientific

    Easy-to-use format eliminates contamination Pure gas output 99.9999% or 6.0 grade No carrier gas line contamination during filter change Easy and fast replacement without the need for tools No risk of overtightening fittings Reuseable end fittings reduce cost of clean gas:…

  • Septa

    Thermo Scientific

    A wide range to cover most applications Variety of materials and temperature limits for all applications For use in Thermo Scientific TRACE and Thermo Scientific FOCUS GCs and instruments from other manufacturers Contaminant-free in individual blister packs Temperature limit: 400°C

  • TraceGOLD TG-5HT GC Columns

    Thermo Scientific

    TraceGOLD TG-5HT columns offer extened operation up to 400°C, ideal for high temperature GC applications. Features: Low polarity, 5% diphenyl/95% dimethyl polysiloxane Lower bleed and better inertness than comparable high-temperature columns Special design of fused silica tubing extends…

  • GFM Pro Electronic Flowmeter

    Thermo Scientific

    The GFM Pro Flowmeter is specifically designed for use with gas chromatography (GC) instruments. This versatile product is an electronic device capable of measuring volumetric flow for all types of gases. Real-time measurements can be made for various types of flow paths including continually…

  • Uniguard Direct-Connection Guard Cartridge Holders

    Thermo Scientific

    Thermo Scientific* Uniguard Direct-Connection Guard Cartridge Holders are reusable, stainless-steel guard cartridge holders that attach directly to the analytical column inlet—eliminating requirement for extra fittings. With PEEK 0.0625 in. male outlet that fits many columns 0.0625…

  • Ferrules for Agilent 5890, 6890 and 6850 Instruments

    Thermo Scientific

    Wide range of choices for a wide range of instruments and applications Thermo Scientific ferrules are available in three different materials and various dimensions to match the instrument and capillary column ID. The choice of material is dependent upon the use. 15% Graphite/85% Vespel…

  • TraceGOLD TG-POLAR GC Columns

    Thermo Scientific

    Specifically designed polymer and surface treatment overcome traditional problems with high-polarity columns Highly polar phase, 90% biscyanopropyl/10% phenylcyanopropyl polysiloxane, not bonded Strong dipole moment and high selectivity for cis/trans compounds or compounds with…

  • TraceGOLD TG-1701MS GC Columns

    Thermo Scientific

    Feature a mix of cyano and phenyl groups for increased polarity and a different elution order relative to less polar columns Mid-polarity phase, 14% cyanopropylphenyl, 86% dimethyl polysiloxane Fully characterized for long-term reproducibility, column-to-column consistency and low bleed …

  • TRACE™ TR-FFAP GC Columns

    Thermo Scientific

    Low bleed even at elevated temperatures. Chose the Thermo Scientific™ TRACE™ TR-FFAP GC Columns for outstanding robustness in difficult-to-analyze separations. Engineered Specifically for FFAP Analysis: Polar phase, TPA modified polyethylene glycol Bonded FFAP phase …

  • TraceGOLD TG-WaxMS GC Columns

    Thermo Scientific

    Manufactured for better column-to-column reproducibility Polar phase, polyethylene glycol Polar-deactivated surface tightly binds polymer for excellent thermal stability Resists oxidative damage, damage from strongly acidic or basic volatiles better than silicone solid phases …

  • TraceGOLD TG-VRX GC Columns

    Thermo Scientific

    Proprietary stationary phase Optimized dimensions for analysis of volatile organic pollutants Ideally suited for US EPA Methods 502.2, 524.2, 8021, and 8260 Similar to DB-VRX, Rtx-VRX Recommended for: Volatile organic pollutants Aromatics

  • Super Clean™ Gas Cartridge Filters

    Thermo Scientific

    Super Clean Cartridge Filters 99.9999% pure gas (or 6.0 grade) output No carrier gas line contamination during cartridge change Cost effective TUEV approved Max. pressure 11 bar (160 psi) Max. flow 7L/min.

  • Injection Port Liners for Agilent Instruments

    Thermo Scientific

    Highly deactivated and produced to exacting tolerances to ensure a high degree of reproducibility

  • TraceGOLD TG-1MS GC Columns

    Thermo Scientific

    Exceptionally low bleed for optimal signal-to-noise ratio, sensitivity and mass spec integrity Non-polar, 100% dimethyl polysiloxane Equivalent to USP G2 Applications: Hydrocarbons PCBs Drugs of abuse Gasoline range organics (GRO) Refinery gases …

  • Autosampler Syringes for Agilent Instruments

    Thermo Scientific

  • TRACE™ TR-5MS GC Columns

    Thermo Scientific

    Thermo Scientific™ TRACE TR-5MS GC Columns feature a popular GCMS phase for many applications. Nonpolar phase, 5% phenyl polysilphenylene-siloxane Low bleed and high stability High signal-to-noise for increased sensitivity High robustness to oxygen and water contamination …

  • TraceGOLD TG-624 GC Columns

    Thermo Scientific

    Offers 90+% resolution of the first six gases in EPA Method 8260 and EPA Method 524.2 for volatile organics analysis Low to mid-polarity phase, 6% cyanopropylphenyl/94% dimethyl polysiloxane Ideal for EPA methods 624 and 608 Allows resolution of 2-nitropropane from 1,1-dichloropropanone…

  • Super Clean Cartridge Filter Baseplates

    Thermo Scientific

    One-time installation procedure Can be configured to the individual user requirements Needle valves ensure gas line is not contaminated during cartridge change NOTE: Filters are not included.

  • TraceGOLD TG-5MS GC Columns

    Thermo Scientific

    The most widely used MS phase in gas chromatography Low polarity phase, 5% diphenyl/95% dimethyl polysiloxane Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity Exceptional inertness ideal for analysis of active compounds Equivalent to USP G27…

  • TraceGOLD TG-5SilMS GC Columns

    Thermo Scientific

  • TraceGOLD TG-225MS GC Columns

    Thermo Scientific

    Offers better thermal stability than comparable columns Polar phase, 50% cyano propylmethyl/50% phenylmethyl polysiloxane Innovative deactivation process for siloxane reduces tailing and improves efficiency over comparable columns Equivalent to USP G7, G19 phases Applications: …

  • TraceGOLD TG-5HT GC Columns

    Thermo Scientific

    Offers extended operation up to 400°C, ideal for high temperature extended GC applications Low polarity, 5% diphenyl/95% dimethyl polysiloxane Lower bleed and better inertness than comparable high-temperature columns Special design of fused silica tubing extends column lifetime…

  • Acclaim™ Mixed-Mode WAX-1 Columns, 5µm

    Thermo Scientific

    Use Thermo Scientific™ Acclaim™ Mixed-Mode WAX-1 Columns when powerful selectivity control for the separation of anionic molecules is necessary. The silica-based stationary phase features a hydrophobic alkyl chain with an ionizable terminus that provides both hydrophobic reversed-phase…

  • TraceGOLD TG-1301MS GC Columns

    Thermo Scientific

  • TraceGOLD TG-5MS AMINE GC Columns

    Thermo Scientific

    Analysis of ppm levels of amines without column priming Low polarity phase, 5% diphenyl/95% dimethyl polysiloxane Tubing surface is chemically altered to reduce tailing of active basic compounds Also allows analysis of neutral or weakly acidic compounds (e.g., phenols) and compounds…

  • TraceGOLD TG-WaxMS A GC Columns

    Thermo Scientific

    Acidic functionality in the polymer structure allows analysis of acidic compounds without derivatization Polar phase, acid-deactivated polyethylene glycol Resists oxidative damage and adsorption of acids Excellent peak shapes for high MW acids Equivalent to USP G25, G35 phases …

  • Liner Sealing Rings

    Thermo Scientific

  • TraceGOLD TG-35MS GC Columns

    Thermo Scientific

    Higher phenyl content for useful elution order and retention time changes Mid-polarity phase, 35% diphenyl/65% dimethyl polysiloxane Equivalent to USP G42 phase Applications: Organochlorine pesticides and herbicides Pharmaceuticals PCB cogeners Aroclor…

  • TraceGOLD TG-200MS GC Columns

    Thermo Scientific

    Exceptionally inert mid-polarity columns with selectivity and elution order optimized for difficult separations Polar phase, Trifluoropropylmethyl polysiloxane solid phase resolves compounds that phenyl and cyano phases cannot Outstanding thermal stability and low bleed Suitable for…

  • Biobasic-18, 2x50mm, 5u

    Thermo Scientific

  • TraceGOLD TG-17MS GC Columns

    Thermo Scientific

    Particularly suited to GCMS applications that require more polarity than a 5% Phenyl phase Mid-polarity phase of 50% diphenyl/50% dimethyl polysiloxane Ideal for confirmational analysis Excellent inertness for active compounds such as pesticides Very low bleed ideal for analysis by…

  • TraceGOLD TG-WaxMS B GC Columns

    Thermo Scientific

    Base deactivation allows analysis of basic analytes without derivatization or column priming Polar phase, base deactivated polyethylene glycol phase Reduced absorption and improved responsiveness for basic compounds Not suitable for use with water or alcohols Applications: …

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.