Gas Chromatography Columns, Columns, Nucleic Acid, PerkinElmer
-
Our new line of Velocity fused silica columns yield exceptional performance for general Gas Chromatography (GC) applications without the cost associated with gas chromatography and mass spectrum analysis. PerkinElmer Velocity columns are excellent for standard daily test applications. They combine…
-
Elite-5 capillary column, 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C
-
Elite 624 capillary column 30m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Elite-1 capillary column, 40m x 0.18mm, 0.40µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-1 capillary column, 15m x 0.32mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
-
Elite-1 capillary column, 15m x 0.53mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Temperature range -60oC to 200 oC
-
Elite-1 capillary column 60m x 0.32mm, 1.50µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases. Temperature range -60°C to 310/330°C.
-
Temperature range: -20 to 320 degrees celsius. Similar to USP G43 phase.
-
Deactivated Tubing is perfect for making guard columns and retention gaps. Use Splitters(p/n N9303448) and connectors (p/n N9302149) to attach tubing to polymide coated columns.
-
Elite-502.2 Columns are fused silica columns are for analysis of volatiles with EPA 502.2
-
Elite-1 capillary column, 105m x 0.45mm, 2.55µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-1 capillary column, 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
-
Elite 624 capillary column 30m x 0.32mm, 1.80µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Refinery Gas Analyzer Calibration Blend without Syringe Adapter
-
Elite-5ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G27, G36 phases.
-
Elite-1 capillary column, 15m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-200 capillary column 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 290/310°C.
-
The Elite-SimDist columns are specifically for the simulated distillation application. The phase is specifically processed for dimethylpolysiloxane.
-
Elite-WAX capillary column 60m x 0.45mm, 0.85µm
PerkinElmerTemperature range 20oC to 240/250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
-
-
Elite 1301 capillary column 30m x 0.25mm, 1.00µm
PerkinElmerTemperature range -20°C to 260/280°C Equivalent to USP G43 phase
-
Temperature range -60°C to 300/315°C.
-
Elite 1301 capillary column 30m x 0.25mm, 0.25µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
Temperature range -60oC to 200 oC
-
Elite-WAX capillary column 30m x 0.32mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
-
Elite-WAX capillary column 30m x 0.53mm, 1.00µm
PerkinElmerTemperature range 20oC to 240/250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Glass Empty Column, 2mm i.d., 1/4in o.d., 3 ft for AutoSystem GC (on column)