Gas Chromatography Columns
Key features of GC columns include their use of molecular sieve columns, which offer high efficiency in separating small molecules like gases and volatile organic compounds. Integrating fused silica in these columns improves their thermal stability and reduces reactivity, ensuring accurate and consistent results. The columns' design maximizes the interaction between the stationary phase and the analyzed compounds, leading to more precise identification and quantification.
In practical terms, users benefit from the columns' reliability in various applications, including environmental testing, forensic analysis, and quality control in manufacturing. Their design and material composition makes them a valuable asset in any laboratory focused on gas chromatography.
-
HYDRODEX Capillary Columns
MACHEREY-NAGELHYDRODEX cyclodextrin phases Capillary columns for GC enantiomer separation Features Base material: cyclic oligosaccharides consisting of seven (β-cyclodextrin) or eight (γ-cyclodextrin) glucose units bonded through α-1,4-linkages Regioselective derivatization…
-
Elite-1 capillary column, 30m x 0.25mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
low- to midpolarity phase The unique polarity of the Rtx-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx-502.2 column is recommended in many methods, the Rtx-624 column offers better resolution of early eluting compounds. The Rtx-624 phase produces greater…
-
low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the MXT-5 polymer,…
-
Advantages of metal MXT PLOT columns include: Can be made in small coil diameters—perfect for tight spaces. Rugged material withstands rough handling and shock. Designed for robust performance in process GCs and field instruments. Available in 3.5"-coil diameter or…
-
Restek GC Packing Material
RestekHayeSep® porous polymers are macroporous, spherical, ultrapure resins for performing unique separations in gas chromatography. Columns packed with HayeSep® polymers produce lower bleed and more reproducible characteristics than those packed with any competing polymeric product, and they require…
-
Elite-1 capillary column, 15m x 0.25mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
3x faster multiresidue pesticides analysis in foods. Factory-coupled, leak-free kit makes setting up LPGC as simple as a column change. Ideal for speeding up GC-MS and GC-MS/MS methods. Integrated transfer line reduces background and stabilization time.
-
DB-5ms
Agilent TechnologiesPhenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…
-
OPTIMA® BioDiesel Capillary Columns
MACHEREY-NAGELOPTIMA® BioDiesel Capillary columns for the analysis of BioDiesel (DIN EN 14214 / ASTM D 6751) OPTIMA® BioDiesel F for analysis of FAMEs in accordance with DIN EN 14103:2011 The analysis of biodiesel requires separation of typical FAMEs between myristic acid (C14) and nervonic…
-
HP-Plot Q
Agilent TechnologiesBonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…
-
CP-Wax 58 FFAP CB Capillary Columns
Agilent TechnologiesAgilent J&W CP-Wax 58 FFAP CB column is a nitroterephthalic acid-modified, chemically bonded polyethylene glycol phase. It is designed for the analysis of acidic compounds, such as phenols, and underivatized as well as derivatized free fatty acids. Nitroterephthalic acid-modified…
-
Elite 1301 capillary column 10m x 0.18mm, 0.40µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
SLB®-5ms Capillary GC Column
MilliporeSigmaApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles,…
-
Similar to CG-1198 but with a COARSE porosity disc sealed into the lower end of the column for packing support. Column is constructed using MEDIUM WALL tubing. Can be used with optional CG-1201 flow controller and CG-1200 reservoir. Lower end of the column has a round bottom. Connections between…
-
Polyethylene Glycol Industry standard wax column Polar phase Cross-linked for stability and washing Application Areas: alcohol, free acids, fatty acid methyl esters, aromatics, solvents, essential oils Operating Temperature: 0.1-1.0µm film thickness:…
-
polar phase; Crossbond polyethylene glycol Rtx-Wax columns are the most inert and efficient PEG columns currently available. The extended operating temperature range allows analysis of compounds having a wide volatility range and ensures low bleed at temperatures as high as 250°C.…
-
DB-1701p
Agilent TechnologiesLow/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701,…
-
-
HP-Voc
Agilent Technologies• New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
SCOT Capillary GC Column phase TCEP
MilliporeSigmaSupelco is the leader in Support Coated Open Tubular (SCOT) GC column technology. Our unsurpassed manufacturing technique allows us to deposit a uniform layer of liquid phase-coated support particles on the inner wall of stainless steel tubing. This technology gives us access to many phases that…
-
DB-624
Agilent TechnologiesSpecifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…
-
OPTIMA® WAX Capillary Columns
MACHEREY-NAGELOPTIMA® WAX Capillary columns for GC Features Polyethylene glycol 20 000 Da USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax,…
-
-
GC Capillary Guard Column
Agilent TechnologiesJ&W DB-5ms is a non-polar phenyl arylene polymer gas chromatography (GC) Column, virtually equivalent to (5%-phenyl)-methylpolysiloxane, featuring an excellent signal-to-noise ratio for analytical applications. This improved performance gives better sensitivity and mass spectral integrity, and…
-
Special Columns for Unsaturated Light Hydrocarbons Faster separations of C1 to C4 hydrocarbons This 3-column set is finely tuned to resolve light hydrocarbons. When used in the proper valving system, it will elute C5+ hydrocarbons ahead of C1 through C4 hydrocarbons. 88004-875: To be…
-
Rtx-CLPesticides Column Kit
RestekApplication-specific columns for organochlorine pesticides and herbicides. Low bleed—ideal for high sensitivity GC-ECD or GC-MS analyses. Baseline separations in less than 10 minutes. Stable to 320–340°C Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and…
-
General purpose column having a PTFE stopcock and a top Rodaviss® outer joint. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number…
-
Similar to CG-1202 but with a COARSE porosity fritted disc sealed into the lower end of the column for packing support. Column is constructed using MEDIUM WALL tubing. Can be used with CG-1201 flow controller. Connection between the column and flow control adapter are spherical joints connected…
-
Crossbond 5% diphenyl/95% dimethyl polysiloxane—optimized for hydrocarbon analysis
-
Elite 1301 capillary column 30m x 0.25mm, 1.00µm
PerkinElmerTemperature range -20°C to 260/280°C Equivalent to USP G43 phase
-
Glass Empty Column, 2mm i.d., 1/4in o.d., 3 ft for AutoSystem GC (on column)