Solvent Trap

Compare Tool

Select up to 3 products

Solvent Trap
1 - 32 of 96
Sort
View
Show
  • Efficiently traps water vapor and toxic substances discharged from vacuum oven and rotary evaporator to protect the vacuum pump Features Excellent choice to extract acid and organic solvents with the optional glass condenser Efficiently reduces vapor inhalation amount to the vacuum…

  • Trap is designed for large volume solvent vapor removal during rotary evaporation. Trap is placed between the vacuum source and the rotary evaporator to prevent solvent vapors from entering the vacuum pump. PLASTIC COATED to contain solvent in case of breakage and supplied complete with a…

  • Liquid Trap, is placed between the RapidVap and diaphragm pump to prevent liquids from entering the pump when using high boiling point solvents. Consists of borosilicate glass container with 2550 milliliter trapping capacity, two 1/2" diameter stems with elbows, foam insulation lid, and…

  • Trap connects in series with a freeze dry system or vacuum evaporation system and vacuum pump to prevent contaminants from migrating into the vacuum pump. An insulated well, when dry ice and solvent are added, cools to approximately -75° C (-103° F). When used alone, Dry Ice Secondary Trap

  • EZwaste® Solvent Waste System

    Foxx Life Sciences

    EZ-Waste Solvent Waste System is designed to be an affordable solution for liquid waste disposal.Carbon exhaust filter traps solvent vapors,tube fittings secure waste tubes to carboy, providing the closes system necessary to prevent spills. 90° adapter included for maximum storage flexibility.…

  • …the cold trap and can hold various trap inserts. These trap inserts remove acids, moisture, radiochemicals or solvents to minimize release of contaminants into the atmosphere. Overall dimensions: 14.5” (W) x 24.2” (D) x 13.8”(H), weight: 70 lbs. Ultra-Low Cold Trap measures…

  • …catalog number. Just add a vacuum pump and you will be ready to concentrate your samples! CentriVap Solvent Systems are for concentrating organic solvents. They include a Benchtop Concentrator with Glass Lid, Glass Lid Cold Trap, Clear Canister, Solvent Insert, 12-13 mm Rotor and Vacuum Tubing.

  • …C (Cold trap) for low boiling point solvents Protective Coating: Without Recirculating Chiller: Without Vacuum Controller: I-100, with Woulff bottle Vacuum Pump: V-100, 1.5 m3/h, 10 mbar 1190U73 Glass Assembly: C (Cold trap) for low boiling point solvents Protective…

  • …of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also be installed. 1230D92 - Secondary Cold Trap, Glass, If dry ice is used instead of cooling water, a suitable cold trap can also be…

  • Dry Ice Cold Traps are recommended for pumps when doing rotary evaporation, drying solvents, vacuum distillation, centrifugal concentration or any other process involving volatile solvents. 2.8 L center well that holds a dry-ice and alcohol slurry capable of producing temperatures as low as…

  • …of residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also be installed. 1230D92 - Secondary Cold Trap, Glass, If dry ice is used instead of cooling water, a suitable cold trap can also be…

  • …and PILOT5000C-02 diaphragm vacuum pump are durable and chemical resistant. All contact surfaces are PTFE coated. They come with a liquid inlet trap and vacuum regulator making it a perfect choice for vacuum filtration, desiccation, and other mid-range vacuum applications. The TLD5000 and…

  • traps: activated carbon, molecular sieve, or desiccant. Excellent for protecting vacuum pump systems from solvent vapor or gaseous contaminants and aqueous aerosols. Designed for in-line use with stepped barb connections for 10 to 12 mm i.d. hose. Available with choice of chemical trap:

  • …allows bubbles entrained in the inlet fluid stream to rise and be trapped in the reservoir. The gas/liquid interface is easily visible through the translucent wall of the device. Loosening the airtight cap releases the trapped gas. The debubbler features a polypropylene body and bracket; universal…

  • Formula: CH3OH Formula Weight: 32.04 CAS Number: 67-56-1 Synonym(s): Methyl Alcohol

  • …organic solvent. Polypropylene is largely inert, compatible with many chemicals, and retains stability across a range of temperatures. The 0.2 µm high-flow polypropylene membrane and housing makes Solvent IFD suitable to filter and degas these solvents. In-line filter design The Solvent IFD’s…

  • …cold trap not to condense liquid oxygen (a light blue liquid) into the cold trap. Liquid oxygen is potentially explosive, and this is especially true if the trap has been used to trap solvent. Liquid oxygen can be condensed into a cold trap if a pump has sucked air through the trap when the trap is…

  • …cold trap not to condense liquid oxygen (a light blue liquid) into the cold trap. Liquid oxygen is potentially explosive, and this is especially true if the trap has been used to trap solvent. Liquid oxygen can be condensed into a cold trap if a pump has sucked air through the trap when the trap is…

  • …a wide variety of solvent vapors that can contaminate and degrade vacuum pump oil with Thermo Scientific™ Savant™ Refrigerated Vapor Traps (RVT). The RVT safely recovers the solvent and reduces emissions of hazardous chemicals in the environment. Solvents are removed from samples…

  • Moisture Trap

    Ace Glass

    For solvents heavier than water. Used in the method of quantitative separation and determination of glycol mixture by azeotropic distillation described in Analytical Chemistry, Vol. 29, No.1, Page 100. Capacity is 121/2mL, graduated in 0.1mL. Joints are standard taper 24/40.

  • Dean-Stark Moisture Traps

    SP Wilmad-LabGlass

    Calibrated "to contain" at 20°C, these borosilicate glass moisture traps are used for the determination of water in various materials by distillation with an immiscible solvent. They consist of a full length Standard Taper inner joint for vapor tube connection to distilling flask and a…

  • Self washing, rotary evaporator trap design by Dr. William Boulanger. Superior design prevents blow-through and enables continuous addition with rotary evaporators. Solvent vapor rapidly flows out while condensed solvent continuously rinses both the trap walls and the evaporator shaft returning any…

  • Connect a vapor trap using the vent port to prevent solvent vapors from escaping Use without any fittings or use male Luer fittings to connect various tubing sizes Anti-twist design The T-series solvent bottle caps help contain vapors and protect lab staff from exposure to toxic…

  • Prevent chemical vapors from escaping from solvent containers Use traps with Luer connection with T-series solvent waste caps without valve and filter. Traps with 1/4"-28 UNF(M) connection works with caps with vent. Traps with UNF connection feature an indicator strip that changes color as…

  • Methanol, B&J Brand®, Purge & Trap Grade

    Honeywell Burdick & Jackson

    Purge & Trap Grade Suggested Applications: For VOC Analysis using Purge & Trap methods Synonyms: Methyl alcohol, Carbinol, Wood alcohol Structural Formula: CH3OH CAS number: 67-56-1 Hazard Class: 3 Package Group: II UN number: UN1230

  • …through tubes; -10 to 0 psi when using male Luer connectors. All caps are autoclavable. Use activated carbon vapor trap with Luer connection to prevent any dangerous solvent from escaping into the laboratory. Connect 1/16" or 1/8" ID flexible tubing or 1/16” OD semi-rigid tubing…

  • …the Solvent IFD is used with organically based HPLC mobile phases. Specifically, the Aqueous IFD is designed to work with mobile phases containing at least 20% of the aqueous component. The Aqueous IFD has a 0.2 µm hydrophilic nylon membrane for use with aqueous-based mobile phases. Solvent IFD has…

  • CH3OH CAS#: 67-56-1 F.W.: 32.04

  • …volume solvent removal. Lower reservoir has a capacity of either 500 or 1000mL, with a 4mm PTFE stopcock. Serrated hose connections are 12mm at the smallest serration and 14mm at the largest serration. Optional UHMW Lid prevents evaporation of dry ice/acetone in trap. PLEASE NOTE: CG-4517 TRAPS

  • …and bituminous materials, these borosilicate glass Bidwell-Sterling moisture traps collect liquefied vapor. They feature a connection between top of vapor tube and graduated tube. This construction allows excess solvent to return to flask with minimal chance of condensed moisture return. Standard…

  • …inner joint. Trap is placed between the vapor tube and the evaporation flask. This design prevent possible contamination in the event of bumping. Frit reduces foam overflow from being drawn into the condenser. With two 4mm drain holes at the base of the inner tube to allow solvent to drain back…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.