  • … Zorbax strong ion-exchange columns are available as both Strong Anion Exchange (SAX) and Strong Cation Exchange (300SCX) columns. Each column is packed with bonded, 5 µm, spherical silica particles for optimum efficiency. Zorbax Strong Anion Exchange packing has a permanently bonded…

  • …diffusion disc from the column Packing Reservoir Funnels The funnels are used for initial column packing and as a small buffer reservoir. Available in two capacities: 100 mL for the 0.7, 1.0 cm and 1.5 cm ID columns and 700 mL for the 2.5 cm columns Manufactured from…

  • Designed for metal recovery using Ion-Exchange resins such as Amborane. Borosilicate glass column has #25 Ace-Thred at both ends. Polypropylene end fittings form a leak-tight seal with FETFE O-Rings. Fittings have 1/4" npt female thread for connecting 3/8" O.D. flexible vinyl tubing from…

  • Flex-Column Economy Chromatography Columns

    DWK Life Sciences (Kimble)

    Ideal for use with gel filtration, ion exchange, affinity and adsorption media Economical Easy to use Universal fittings and tubing connections Ideal for use with gel filtration, ion exchange, affinity and adsorption media. Polypropylene reservoirs and column outlets are permanently connected…

  • The Maxi Plasmid ion-exchange resin replacement columns can be used with most kits on the market today that utilize lysis, bind, wash, elute steps. Column specifications must be observed. Sample Size: 100ml High-copy or 250ml Low-Copy Plasmid. Elution Volume: 50µl. Binding Capacity: up to…

  • Extract acidic analytes with a negative charge from aqueous samples TELOS SAX (quarternary amine) columns have average pore diameter of 70 Å with 0.4 meq/g exchange capacity. All columns are made of polypropylene and come with Luer-slip outlet. Ionizable acidic analytes with pK range 2 to…

  • Extract basic analytes with a positive charge from aqueous samples TELOS SCX (benzenesulfonic acid) columns have average pore diameter of 70 Å with 0.6 meq/g exchange capacity. All columns are made of polypropylene and come with Luer-slip outlet. Ionizable basic analytes with pK range 8…

  • 5µm particle size, 300 Angstrom pore size Proprietary, protein-friendly, ion exchange ligands of polyethyleneimine (PEI) bound to pure deactivated silica Low hydrophobicity Capacity of 0.22mEq/g; 3% carbon load Use for normal phase and hydrophilic interaction chromatography (HILIC) Stable…

  • Basic Glass Columns

    DWK Life Sciences (Kimble)

    420300 series are basic columns used for many separations in adsorption and ion exchange chromatography Glass wool (not supplied) is used to support column packing Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A…

  • … Theproperties of the G-Trap™ Ion Exchange Selection Kit resin and the column are listed below G-Trap™ Ion Exchange Selection Kit resin G-Trap™ CM Agarose Fast Flow resin Ion Exchange r: Weak cation exchanger Matrix : Cross-linked agarose beads, 6%…

  • Ion-Exchange DEAE Columns

    Separation Methods Technologies

    SMT-DEAE [Di-Ethyl-Amino-Ethyl] column provides a unique chemically attached hydrophilic, weak anion exchange type, functional surface desirable for the separation of many biomolecules such as proteins, nucleotides, oligonucleotides, polynucleotides, high molecular weight RNA?s and plasmid DNA?s.…

  • Ion-Exchange WAX Columns

    Separation Methods Technologies

    SMT-WAX columns are silica-based Weak Anion eXchange packing materials developed for separation of anionic compounds. SMT-WAX consists of chemically attached hydrophilic surface derivatized to form polyethyleneimine functionality. The technique of SAM is used in the bonding process to significantly…

  • Ion-Exchange WCX Columns

    Separation Methods Technologies

    SMT-WCX columns are silica-based Weak Cation eXchange packing materials developed for separation of cationic compounds. SMT-WCX consists of chemically attached hydrophilic surface derivatized to form carboxylic acid functionality. The technique of SAM is used in the bonding process to significantly…

  • …than SCX—ideal for isolating and purifying basic compounds following organic synthesis. SCX-2 columns have average pore diameter of 70 Å with 0.3 meq/g exchange capacity. All columns are made of polypropylene and come with Luer-slip outlet. Ionizable basic analytes with pK range 8 to…

  • …Bio Ion Exchange HPLC columns are packed with polymeric, nonporous, ion exchange particles. Bio Ion Exchange Columns are designed for high resolution, high recovery and highly efficient separations of peptides, oligonucleotides and proteins. The Bio IEX family offers strong cation exchange (SCX),…

  • Ion-Exchange SAX Columns

    Separation Methods Technologies

    SMT-SAX columns are silica-based Strong Anion eXchange packing developed for separation of anionic compounds. SMT-SAX packings consist of chemically attached hydrophilic surface derivatized to form quaternary amine. The technique of SAM is used in the bonding process to significantly increase the…

  • Ion-Exchange SCX Columns

    Separation Methods Technologies

    SMT-SCX columns are silica-based Strong Cation eXchange packing materials developed for separation of cationic compounds. SMT-SCX consists of chemically attached hydrophilic surface derivatized to form sulfonic acid functionality. The technique of SAM is used in the bonding process to significantly…

  • …Guides. Features  Hands-on ion exchange chromatography lab activity. Applications The principle ion exchange chromatography. Immobilization of protein on ionic charged columns. Factors influencing binding and elution of proteins in ion exchange chromatography.

  • …devices are ready-to-use and do not bear the risk of running dry. The rapid 1-2-3 bind- wash-elute protocol can replace time-consuming and tedious column chromatography. Available in three membrane chemistries: Sulphonic acid (S), Quaternary ammonium (Q), and Diethylamine (D). Vivapure mini:…

  • …5,000 psi. The PRP-X200 columns are designed for use in all of today’s ion chromatographic equipment. Since exchange capacity is low, background signal is low. This allows low detection limits at the highest conductivity detector settings. Pack Your Own Columns - Hamilton offers a range…

  • … Higher ion exchange capacity support for separation of closely related carbohydrates Compatible with PAD and RI detectors   One particle size: 7 μm Three column internal diameters: 2.1 to 4.6 mm Two column materials: Stainless steel and PEEK Guard column in PEEK …

  • …of Ion Exchange Chromatography and protein purification.  The kit contains the reagents to allow students to: Equilibrate a DEAE agarose column Load a protein sample on the column (amylase, lysozyme or a mixture of both)  Wash the unbound protein sample from the column Bind…

  • …µm Pore size 100 Å Separation mechanism includes steric exclusion, ligand exchange and partition effects, ligand exchange being the predominant force, since the hydrated metal ions form strong interactions with the hydroxyl groups of the sample molecules. Recommended…

  • Accessories for Vivapore 5 and 10/20 static concentrators. Accessories for Vivapure Ion Exchange Columns and Viivapure Purification Kits.

  • Requires holder P/N 07150013.

  • Biobasic SCX 5µm Column

    Thermo Scientific

    … Thermo Scientific BioBasic SCX Columns are optimized for the separation of proteins, peptides and other cationic species. BioBasic SCX Columns are a range of high performance columns for the analysis of proteins, peptides and other biomolecules with higher efficiency than polymeric ion exchange.

  • These columns, nominally 20mL, have an inner diameter of 1.5 cm and a "packable" volume of 17mL. Use them when a large bed volume of one of Eichrom's extraction chromatography or ion exchange resins is required. Columns are supplied with bottom frit pre-inserted, in packages of 20,…

  • Reliably analyze a wide variety of polar analytes (acidic, basic, and neutral) without time-consuming derivatization or complex ion pairing. Switch between HILIC and ion-exchange retention modes with simple mobile phase changes and short equilibration times. 2.7 μm Raptor core-shell…

  • Glass Columns with Fritted Disc

    DWK Life Sciences (Kimble)

    Basic column used for many separations in adsorption and ion exchange chromatography. 40-60 micron porosity fritted disc is sealed in Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements

  • SEC/GPC Columns

    Separation Methods Technologies

    SMTgel (silica-based) columns are specialty SMT columns designed for specific applications including gel permeation (GPC), ion exchange, reversed phase, hydrophobic interaction, hydrophilic interaction, and affinity chromatography. The packing materials feature modified surface chemistry designed…

  • Ion Exchange Selection Kit is available for initial screening for the appropriate ion exchanger to purify target protein. G-Trap™ Ion Exchange Agarose Fast Flow Columns are ready to use prepacked columns for separation of biomolecules on the basis of charge. G-Trap™ Ion Exchange

  • Ion Exchange Selection Kit is available for initial screening for the appropriate ion exchanger to purify target protein. G-Trap™ Ion Exchange Agarose Fast Flow Columns are ready to use prepacked columns for separation of biomolecules on the basis of charge. G-Trap™ Ion Exchange

Compare Tool