Filter Calibration Spectrophotometer
-
Spectroquant® Prove 300 UV/VIS Spectrophotometer
MilliporeSigma…complimentary calibration updates. Just insert the reagent cell and AutoSelector into the spectrophotometer. Thanks to ambient light protection, you don’t even have to close the lid. Prove 300 will detect the test method, lot number, expiry date, and calibration updates from the…
-
…and visible range (200 to 700 nm). The wavelength accuracy filter is made from holmium oxide and has ten NIST-certified calibration peaks. The UV photometric accuracy filter is made from didymium and has five NIST-certified calibration peaks and five photometric calibration points in the UV range.
-
Secondary calibration standard for absorbance accuracy of Spectrophotometers in the visible range. Certified.Neutral density glass filter (nominal absorbance: 0.5 at 440; 465; 546,1; 590; 635 nm) Legal Information: Hellma is a registered trademark of Hellma GmbH Other Notes: The most current…
-
Secondary calibration standard for absorbance accuracy of Spectrophotometers in the visible range. Certified.Neutral density glass filters (nominal absorbance: 1.0 at 440; 465; 546,1; 590; 635 nm) Legal Information: Hellma is a registered trademark of Hellma GmbH Other Notes: The most…
-
Helios UV-Vis Scanning Spectrophotometers
Thermo Scientific UV-Vis…systems. Sample Handling Calibration Accessories The Calibration Validation Carosel (8404A19) performs automatic unattended instrument performance checks on the Helios Alpha and Beta spectrophotometers. These checks include all critical UV-VIS spectrophotometer performance parameters…
-
Accessories for Helios Zeta And Helios Omega Spectrophotometers
Thermo Scientific UV-Vis… Sample Handling Calibration Accessories The Calibration Validation Carosel (8404A19) performs automatic unattended instrument performance checks on the Helios Alpha and Beta spectrophotometers. These checks include all critical UV-VIS spectrophotometer performance parameters essential…
-
Accessories for the SPECTRONIC 20 and 20D
Thermo Scientific UV-Vis…with 8420Q30 and 8420Q35 to cover tops of 6" test tubes. Inside diameter 35 mm, depth 64 mm. Holium Oxide Filter Used for calibrating any of the Spectronic spectrophotometers. Test Tubes Ungraduated tubes are selected for uniformity and freedom from flaws in light path zone so that…
-
MultiDirect Photometer
Lovibond…with the electronic components. N.I.S.T. Traceability The instrument has a factory calibration, which is related to internal standards, which are not N.I.S.T traceable. The instrument may be calibrated by the user in a “user calibration mode” with N.I.S.T traceable standards.
-
C40 NanoPhotometer®
Implen…including 2 mm, 1 mm, 0.5 mm, 0.1 mm and 0.004 mm. IQ/OQ Package The IQ/OQ package provides a didymium glass filter standard to ensure your instrument is in calibration and complies with the GLP guidelines. Implen has ISO 9001:2008 certification. IMPLEN has been awarded this designation…
-
Double Aperature Accessory
PerkinElmer…to be characterized and corrected for. Typical applications include specular reflectance measurements on very high reflectance laser mirrors and transmittance measurements on filters. Includes a manual containing step-by-step measurement procedures and full details of all calibration calculations.
-
SmartReader UV-Vis Microplate Reader
Benchmark Scientific…accurate and uniform temperature control (4°C to 45°C) - Top reading optical path with continual self-checking and an automatic calibration option for monochromator wavelength and plate positioning. Integrated plate shaker with adjustable values for time and speed Multi-user-operation…